The incorporation of TBAEMA in acrylic resin resulted in copolymerization and the presence of amine groups on specimens' surfaces, and in decreases of Tg and FS.
The aim of the present study was to assess the effect of a denture adhesive (DA) on patient satisfaction and kinesiographic parameters of complete denture wearers by a cross-over study. Fifty edentulous patients received a set of new complete dentures. After an adaptation period, the participants were enrolled in the trial and randomized to receive a sequence of treatment protocols: Protocol 1- DA use during the first 15 days, followed by no DA for the next 15 days; Protocol 2- no DA during the first 15 days, followed by use of DA for the next 15 days. Outcomes were assessed after 15 days of each sequence of treatment. A questionnaire was used to assess the patients' satisfaction. A kinesiograph was used to record mandible movements and patterns of maxillary complete denture movement during chewing. The Wilcoxon test (α=0.05) and a paired sample t-test (α=0.05) were used to compare satisfaction levels and kinesiographic data, respectively. Use of DA improved the overall level of patient satisfaction (p<0.001). The kinesiographic recordings revealed a significant increase (1.7 mm) in vertical mandible movements (p<0.001) during chewing and a lower (0.3 mm) vertical intrusion of the maxillary complete dentures (p=0.002) during chewing after using the DA. Use of DA in complete denture wearers improved the patients' satisfaction and altered mandible movements, with increases in vertical movements during chewing and less intrusion of maxillary complete dentures.
There is a lack of clinical evidence on mandibular overdentures (MOD) supported by a single implant.Objective:To compare patient satisfaction and masticatory performance in MOD supported by one versus two implants in a two-group parallel randomized clinical trial.Material and Methods:Twenty-one patients wearing new maxillary and mandibular complete dentures (CDs) were randomly divided to receive one (GI, n = 11) or two (GII, n = 10) implants in the mandibular arch. Four months after implant placement, o-ring abutments were installed in the implants, and matrix attachments were placed in the lower complete dentures. Patient satisfaction with their dentures and masticatory performance were compared at baseline, 3, 6, and 12 months after the procedure. Data on patient satisfaction were analyzed using the Friedman test and the Mann-Whitney U test. Data on masticatory performance were analyzed using one-way repeated measures analysis of variance (ANOVA) and Student's t test (α=0.05).Results:Both groups exhibited a significant increase in overall patient satisfaction in all periods evaluated (p<0.05), except for GI after 12 months, which had values similar to baseline (p=0.74). Satisfaction levels of GI and GII were similar at baseline, 3 and 6 months, but GII showed higher satisfaction levels (p=0.01) than GI at 12 months. GI and GII exhibited a significant increase (p<0.05) in masticatory performance for all periods relative to baseline. However, GII had higher masticatory performance with dentures than GI, regardless of the period (p<0.05).Conclusion:MOD supported by two implants demonstrated better patient satisfaction in the follow-up at 12 months and better masticatory performance than MOD supported by one implant.
Background: Brushing and consumption of dye beverages may alter the physical properties of artificial teeth. Objective: The objective of this study was to evaluate the effect of toothbrushing and immersion in beverages in roughness and color of two types of artificial teeth: Biotone (B) and Biotone interpenetrating polymer network (IPN). Materials and Methods: For each tooth, seven groups were formed (n = 10): Toothbrushing (T), toothbrushing + water (TW), toothbrushing + coke (TCk), toothbrushing + coffee (TCf ), immersion in water (W), coke (Ck), coffee (Cf ). Roughness and color stability evaluations were performed before treatment and after treatment. According to the group, 11,000 brushing cycles were performed and specimens were immersed in beverages for 12 days, both simulating a period of 1 year. Color variations were captured by a spectrophotometer and roughness was analyzed by a profilometer. Color data were analyzed using analysis of variance (ANOVA) and Least significant difference test whereas roughness data were analyzed using ANOVA and Bonferroni test, both with α =0.05. Results: For Biotone, clinical significant color changes according to National Bureau of Standards (NBS) units were observed for the Groups T, TW, W, and Ck, and the results of ΔE were statistically similar among them (P > 0.05). For Biotone IPN, clinical significant color changes were found for TCf (4.86 NBS units) and Cf (4.82), and the results of ΔE were also similar among them. Surface roughness Ra (µm), regardless of the teeth, was reduced for the groups submitted to toothbrushing whereas no significant differences were found among the Groups W, Ck, and Cf. Conclusions: Toothbrushing had no influence on the color stability but significantly reduced the roughness, irrespective of the type of tooth.
Several attachment systems for mandibular implant-supported overdentures are currently available and studies are required to understand their mechanical properties. The objective of this study was to evaluate the retention force and wear characteristics of three attachment systems in a simulation of the cyclic dislodging of implant-supported overdentures. Thirty samples were fabricated and divided into 3 groups: 1-O-ring; 2-Mini Ball; and 3-Equator. A mechanical fatigue test was applied to the specimens using a servo-hydraulic universal testing machine performing 5500 insertion/removal cycles (f=0.8 Hz), immersed in artificial saliva. Retention force values were obtained before and after 1500, 3000, and 5500 cycles using a speed of 1 mm/min and a load cell of 1 kN. One specimen from each group was randomly selected and analyzed by scanning electron microscopy. Two-way repeated measures ANOVA and the Bonferroni post hoc test were used for statistical analyses (α=0.05). The O-ring system remained stable during all periods tested and exhibited significantly lower retention force values than the Mini Ball and Equator systems. The Mini Ball system exhibited a significant increase in retention force after the mechanical test (baseline=21.04±3.29N; 5500 cycles=24.01±3.30N).The Equator system exhibited a significant decrease in retention force after each period tested, but the values were higher than the other systems. The type of attachment was found to influence retention force in different ways after mechanical tests. The Equator system exhibited the highest retention force values. The Mini Ball and Equator matrices produced deformation and wear on the surfaces without breakage of the polyamide rings.
ObjectivesTo verify whether the Ultra Corega Cream and Corega Strip Denture Adhesive adhesives interfere in the microbial adhesion and biofilm formation by Candida albicans and Lactobacillus casei in single- and mixed-species settings, and observe whether synergistic or antagonistic relationships between these species occur.MethodsSpecimens made from heat-polymerized acrylic resin (Lucitone 550) were fabricated (n = 144) with a circular shape and standardized roughness (3.0 μm ±0.3 Ra) and were divided into three groups: Without Adhesive (WA), with Ultra Corega Cream adhesive (CA) and Corega Strips adhesive (SA). These groups were divided into three subgroups each: C. albicans single-species, L. casei single-species and C. albicans with L. casei (mixed-species). Microbial adhesion and biofilm formation assays were performed in duplicate at four distinct experimental times (n = 8 per experimental condition). The amount of each microorganism on the surfaces of the specimens was observed by counting of the Colony Forming Units (CFU) per substrate. Additional specimens were characterized by Scanning Electron Microscopy (SEM), with 18 specimens being used in this analysis (n = 18), 2 per experimental condition (n = 2). Two-way ANOVA and Tukey’s test for multiple comparisons were employed, using α≤0.05.ResultsL. casei (mixed-species) adhered more on the WA substrate than the CA, while C. albicans (single- and mixed-species) adhered more on the SA. C. albicans, both single- and mixed-species adhered more than the L. casei (single- and mixed-species), regardless of the substrate. L. casei (single-species) formed more biofilm on the WA, but in its mixed cultivation, it had no difference of growth among the tested situations. C. albicans (single- and mixed-species) formed more biofilm on the SA than the CA, and the fungus formed more biofilm when compared to L. casei. In general, whenever a species was compared in its single- and mixed-species situation, no statistically significant difference was observed. SEM of biofilm formation assays demonstrated that L. casei single-species WA formed more biofilm than when the adhesives tested were used, and C. albicans (both single- and mixed-species) formed more biofilm on the SA than on the CA.Conclusions(1) The two denture adhesives tested increased the adhesion of C. albicans but not of L. casei; (2) biofilm formation by C. albicans (single- and mixed-species) was increased on the SA; (3) Relations of synergism or antagonism was not observed between the two microorganisms studied.
The assessment and reestablishment of the occlusal vertical dimension (OVD) are considered important factors in the treatment of complete denture wearers. The long-time use of a complete denture can result in jaw displacement due to abrasion of the artificial teeth and residual ridge resorption, causing esthetic complications. Most patients with old dentures and incorrect OVD accept reestablishment of the OVD with new complete dentures, even if they were used to their old dentures. The present clinical report describes a method of gradual reestablishment of OVD using a diagnostic acrylic splint on artificial teeth in old complete dentures before the manufacture of new complete dentures. Clinical Significance. The use of a reversible treatment for reestablishment of the OVD in old complete dentures with a diagnostic occlusal acrylic splint allows for the reestablishment of the intermaxillary relationship, providing physiological conditions of masticatory performance associated with the recovery of facial esthetics in edentulous patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.