Currently, most clinical range-modulated proton beams are assumed to have a fixed overall relative biological effectiveness (RBE) of 1.1. However, it is well known that the RBE increases with depth in the spread-out Bragg peak (SOBP) and becomes about 10% higher than mid-SOBP RBE at 2 mm from the distal edge (Paganetti 2003 Technol. Cancer Res. Treat. 2 413-26) and can reach values of 1.3-1.4 in vitro at the distal edge (Robertson et al 1975 Cancer 35 1664-77, Courdi et al 1994 Br. J. Radiol. 67 800-4). We present a fast method for applying a variable RBE correction with linear energy transfer (LET) dependent tissue-specific parameters based on the alpharef/betaref ratios suitable for implementation in a treatment planning system. The influence of applying this variable RBE correction on a clinical multiple beam proton dose plan is presented here. The treatment plan is evaluated by RBE weighted dose volume histograms (DVHs) and the calculation of tumour control probability (TCP) and normal tissue complication probability (NTCP) values. The variable RBE correction yields DVHs for the clinical target volumes (CTVs), a primary advanced hypopharynx cancer and subclinical disease in the lymph nodes, that are slightly higher than those achieved by multiplying the absorbed dose with RBE=1.1. Although, more importantly, the RBE weighted DVH for an organ at risk, the spinal cord is considerably increased for the variable RBE. As the spinal cord in this particular case is located 8 mm behind the planning target volume (PTV) and hence receives only low total doses, the NTCP values are zero in spite of the significant increase in the RBE weighted DVHs for the variable RBE. However, high NTCP values for the non-target normal tissue were obtained when applying the variable RBE correction. As RBE variations tend to be smaller for in vivo systems, this study-based on in vitro data since human tissue RBE values are scarce and have large uncertainties-can be interpreted as showing the upper limits of the possible effects of utilizing a variable RBE correction. In conclusion, the results obtained here still indicate a significant difference in introducing a variable RBE compared to applying a generic RBE of 1.1, suggesting it is worth considering such a correction in clinical proton therapy planning, especially when risk organs are located immediately behind the target volume.
Highlights
The patterns of practice for adaptive radiotherapy were evaluated for 177 centres.
Over half performed ad-hoc adaption but less than a third used specific protocols.
CBCT was the main imaging modality in general but MR was used for daily replanning.
2/3 centres wished to implement ART; 40% of them had plans to do it within 2 years.
The main barriers were human/material resources and technical limitations.
Highlights
Real-time respiratory motion management (RRMM) practice, evaluated for 200 centres.
Sixty-eight percent of respondents used RRMM for at least one tumour site.
Across all tumour sites, external marker was the main RRMM signal used.
Overall 71% of respondents wished to implement RRMM for a new treatment site.
The main barriers were human/financial resources and capacity on the machine.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.