Purpose The aim of the underlying study was to present a new surgical method in PreserFlo MicroShunt surgery for glaucoma. A removable polyamide suture was placed into the lumen of the MicroShunt during implantation to prevent early postoperative hypotony. Methods Thirty-one patients undergoing stand-alone glaucoma surgery with implantation of a PreserFlo MicroShunt and an intraluminal occlusion were retrospectively reviewed and compared to a control group without occlusion. Inclusion criteria were diagnosis of primary open-angle glaucoma or secondary open-angle glaucoma due to pseudoexfoliation or pigment dispersion. Patients with a history of filtrating glaucoma surgery were excluded. Results IOP decreased from 26.9 ± 6.6 to 18.0 ± 9.5 mmHg at the first postoperative day after PreserFlo MicroShunt implantation. Postoperative removal of the occluding suture resulted in a mean IOP reduction in 11.1 ± 7.6 mmHg. Mean visual acuity was 0.43 ± 0.24 logMAR during the first postoperative examination. The interval with the occluding intraluminal suture in place varied from days to 2–3 weeks. Patients were followed up to 1 year. Conclusion Implantation of a PreserFlo MicroShunt combined with an intraluminal suture prevented postoperative hypotony in all patients. Mean postoperative pressure was reduced despite the occluding suture in place.
Central subendothelial geographic deposits are formed as a fibrillar layer (FL) in advanced Fuchs endothelial corneal dystrophy (FECD). Previous studies demonstrated a significant decrease in corneal endothelial cell (CEC) density and an increase in focal corneal backscatter in the FL area. The present study investigated the association of the FL with edema formation and its localization. Patients (n = 96) presenting for Descemet membrane endothelial keratoplasty (DMEK) for advanced FECD were included. Slit-lamp biomicroscopy with FECD grading was followed by Scheimpflug imaging with en face backscatter analysis and pachymetric analysis. FL dimensions were measured, and correlation with pachymetric values was performed. An FL was detected in 74% of all eyes (n = 71). Pachymetric values in FL-positive versus FL-negative eyes were for corneal thickness at the apex (ACT) 614 ± 52 µm and 575 ± 46 µm (p = 0.001), for peripheral corneal thickness at 1 mm (PCT1mm) 616 ± 50 µm and 580 ± 44 µm (p = 0.002), for PCT2mm 625 ± 48 µm and 599 ± 41 µm (p = 0.017), for PCT3mm 651 ± 46 µm and 635 ± 40 µm (p = 0.128) and for PCT4mm 695 ± 52 µm and 686 ± 43 µm (p = 0.435), respectively. Correlation analysis indicated a weak correlation for the FL maximum vertical caliper diameter with ACT and PCT1mm values but no further relevant correlations. In FL-positive eyes, increased focal corneal backscatter and increased corneal thickness showed primarily central and inferotemporal localization. In conclusion, Scheimpflug imaging shows an association of the FL with increased corneal thickness in advanced FECD and shows localization of the FL and increased corneal thickness in the central and inferotemporal region. This may provide important information for progression assessment and therapeutic decision making in FECD patients in the future.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.