2022
DOI: 10.1016/j.ajo.2021.08.019
|View full text |Cite
|
Sign up to set email alerts
|

Scheimpflug Backscatter Imaging of the Fibrillar Layer in Fuchs Endothelial Corneal Dystrophy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
9
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(11 citation statements)
references
References 28 publications
2
9
0
Order By: Relevance
“…Slit-lamp biomicroscopy with confirmation of FECD diagnosis and modified Krachmer grading was performed by one of four corneal specialists (OO, CC, BB, MMa): Grade 1: 1–12 non-confluent central guttae; Grade 2: >12 non-confluent central guttae; Grade 3: confluent guttae over 1–2 mm in diameter; Grade 4: confluent guttae over 2–5 mm in diameter; Grade 5: >5 mm diameter confluent guttae; Grade 6: >5 mm diameter confluent guttae and corneal edema [ 8 , 11 ]. Scheimpflug imaging (Pentacam, Oculus GmbH) was performed as part of the routine diagnostic workup, including en face Scheimpflug backscatter analysis (Densitometry display, Pentacam software version 1.22r09) and Scheimpflug pachymetry analysis (Pachymetry display, Pentacam software version 1.22r09) [ 10 ]. Because previous studies have demonstrated the diurnal dependence of pachymetry values in advanced FECD [ 3 , 12 ], the time of day of Pentacam imaging was recorded as AM or PM.…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…Slit-lamp biomicroscopy with confirmation of FECD diagnosis and modified Krachmer grading was performed by one of four corneal specialists (OO, CC, BB, MMa): Grade 1: 1–12 non-confluent central guttae; Grade 2: >12 non-confluent central guttae; Grade 3: confluent guttae over 1–2 mm in diameter; Grade 4: confluent guttae over 2–5 mm in diameter; Grade 5: >5 mm diameter confluent guttae; Grade 6: >5 mm diameter confluent guttae and corneal edema [ 8 , 11 ]. Scheimpflug imaging (Pentacam, Oculus GmbH) was performed as part of the routine diagnostic workup, including en face Scheimpflug backscatter analysis (Densitometry display, Pentacam software version 1.22r09) and Scheimpflug pachymetry analysis (Pachymetry display, Pentacam software version 1.22r09) [ 10 ]. Because previous studies have demonstrated the diurnal dependence of pachymetry values in advanced FECD [ 3 , 12 ], the time of day of Pentacam imaging was recorded as AM or PM.…”
Section: Methodsmentioning
confidence: 99%
“…Scheimpflug imaging data were analyzed by a single cornea specialist (OO) following instruction and joint grading of a pilot series with another experienced grader and cornea specialist (MMa). In the Densitometry display (Pentacam software version 1.22r09), the en face Scheimpflug backscatter plane with the highest backscatter gray scale unit (GSU) at the corneal apex within the posterior corneal 100 µm was selected as described before [ 10 ]. The image was exported in high-resolution quality.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations