Short-term results suggest that intravitreally administered bevacizumab (Avastin) is effective in minimally classic and occult CNV due to AMD. Significant improvements in VA, CFT and TMV were obtained and maintained during follow-up. In some patients, however, recurrence of leakage requiring additional intravitreal injection occurred. Maintenance of the effect of bevacizumab and its safety after repeated and prolonged administration have to be investigated in well-controlled studies.
Dexamethasone intravitreal implant may present an alternative option in the treatment of chronic diabetic macular edema nonresponsive to three consecutive monthly bevacizumab injections administered previously. However, IOP measures were only slightly increased. It seems that the effect of dexamethasone may last till 4 months after initial injection.
PURPOSE:
To evaluate the clinical outcomes including patient-reported outcome measures in a sample of eyes undergoing bilateral cataract surgery with implantation of a new model of presbyopia-correcting intraocular lens (IOL).
METHODS:
This non-randomized prospective case series enrolled 206 eyes of 103 patients undergoing phacoemulsification cataract surgery with bilateral implantation of the TECNIS Synergy IOL (Johnson & Johnson Vision). High and low contrast visual acuity, refractive, defocus curve, and patient-reported visual performance (Catquest-9SF questionnaire) outcomes were evaluated during a 3-month follow-up.
RESULTS:
A total of 96.1% (99 of 103) and 91.3% (94 of 103) of patients achieved binocular postoperative uncorrected distance (UDVA) and near visual acuity (UNVA) of 0.00 logMAR (20/20), respectively. Mean postoperative mesopic UNVA for both eyes was 0.14 ± 0.03 logMAR. Likewise, mean binocular UDVA and UNVA were 0.00 ± 0.03 and 0.04 ± 0.02 logMAR. An almost flat mean defocus curve was obtained, with visual acuities between 0.00 and 0.10 logMAR for most defocus levels in both eyes. A reduction of contrast led to a limited but statistically significant change in UNVA in both eyes (
P
< .001). The Rasch calibrated scoring of item 2 and the Rasch calibrated mean score of the Catquest-9SF questionnaire increased significantly with surgery (
P
< .001).
CONCLUSIONS:
This new presbyopia-correcting IOL provides a continuous range of functional focus, with a limited deterioration under mesopic conditions, which is perceived as a satisfactory outcome by the patient if proper patient selection is performed.
[
J Refract Surg
. 2021;37(4):256–262.]
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.