2021
DOI: 10.3928/1081597x-20210209-01
|View full text |Cite
|
Sign up to set email alerts
|

Clinical Outcomes With a New Continuous Range of Vision Presbyopia-Correcting Intraocular Lens

Abstract: PURPOSE: To evaluate the clinical outcomes including patient-reported outcome measures in a sample of eyes undergoing bilateral cataract surgery with implantation of a new model of presbyopia-correcting intraocular lens (IOL). METHODS: This non-randomized prospective case series enrolled 206 eyes of 103 patients undergoing phacoemulsification cataract surgery with bilateral implantation of the TECNIS Synergy IOL (Johnson & Johnson Vision). High and … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

3
33
0
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 23 publications
(37 citation statements)
references
References 34 publications
3
33
0
1
Order By: Relevance
“…This indicates that the 3 trifocal IOLs evaluated have a similar performance at near (40 cm), with mean UNVA and CNVA values similar to those reported in previous studies. 2,4,5,16,25–28 Specifically, the mean binocular postoperative logMAR UNVA values of 0.01 ± 0.09, 0.01 ± 0.07, and 0.01 ± 0.10 logMAR were found in the Synergy, PanOptix, and Finevision groups of this study, respectively. Kohnen et al reported a mean binocular postoperative UNVA of 0.07 ± 0.11 logMAR in a sample of eyes implanted with the PanOptix trifocal IOL, whereas Gabric et al reported a mean value monocular UNVA of 0.10 ± 0.07 and 0.09 ± 0.06 for right and left eyes implanted with the Synergy IOL, respectively.…”
Section: Discussionmentioning
confidence: 47%
See 4 more Smart Citations
“…This indicates that the 3 trifocal IOLs evaluated have a similar performance at near (40 cm), with mean UNVA and CNVA values similar to those reported in previous studies. 2,4,5,16,25–28 Specifically, the mean binocular postoperative logMAR UNVA values of 0.01 ± 0.09, 0.01 ± 0.07, and 0.01 ± 0.10 logMAR were found in the Synergy, PanOptix, and Finevision groups of this study, respectively. Kohnen et al reported a mean binocular postoperative UNVA of 0.07 ± 0.11 logMAR in a sample of eyes implanted with the PanOptix trifocal IOL, whereas Gabric et al reported a mean value monocular UNVA of 0.10 ± 0.07 and 0.09 ± 0.06 for right and left eyes implanted with the Synergy IOL, respectively.…”
Section: Discussionmentioning
confidence: 47%
“…These results are consistent with those from other series reporting an incidence of disabling glare or halo below 10% for different types of trifocal IOLs. 9,26–28 Monaco et al confirmed in a comparative study that the QoV questionnaire results showed no differences in dysphotopsia between 2 presbyopia-correcting IOLs (PanOptix and Symfony IOLs). 31 Recently, Gabric et al found that disturbing halos were only reported by 1.9% of a sample of 103 patients bilaterally implanted with the Synergy IOL.…”
Section: Discussionmentioning
confidence: 95%
See 3 more Smart Citations