The new MIDHS technique is a trustable procedure that may help the surgeon to perform DHS fixation in a proper way. It offers a better motoric function, less pain. However, further studies should be conducted to evaluate the validity of such radiological land marks in proximal femoral surgery.
Objective:Extracorporeal shockwave therapy (ESWT) has been used successfully in treatment of musculoskeletal disorders. Our objective was to assess the effectiveness of low versus middle-energy ESWT on snapping scapula bursitis.Methods:Thirty-five patients, divided into two groups, group (L), received low-energy ESWT, group (M) received middle-energy ESWT. Groups were evaluated at 1,3,6 and 12 months using the Visual Analogue Scale (VAS), the Constant-Murley scoring (CMS) and the Roles and Maudsley criteria.Results:In groups (L) and (M), VAS average values after 1,3,6 months and one year were (43±5.17, 38±4.33, 28±4.18 and 19±3.39) and (37±4.85, 26±4.74, 21±4.45 and 7±3.42) respectively. At six and twelve months, statistical difference was detected, P (0.034, 0.026) respectively. After one year of completing the treatment, the average values of CMS were (83.5±6.44 and 91±5.33) respectively, P=0.046. Roles and Maudsley criteria demonstrated that, patients in group (L), 6 (35%) excellent, 5 (29%) good, 4 (24%) acceptable and 2 (12%) had poor results. Whereas, patients in group (M), 11 (61%) excellent, 3 (17%) good, 3 (17%) acceptable and 1 (5%) had poor results.Conclusion:Although low-energy ESWT showed good early-term results, but middle-energy ESWT protocol demonstrated better early-term, Mid-term, and late-term results.
ObjectivesThe aim of this study was to analyze the effect of tibial tunnel positioning in single bundle and double bundle ACL reconstructions on lateral meniscus anterior root.MaterialsTwelve single knee cadavers were used, 6 for a single bundle ACL reconstruction, which were reamed gradually starting from 8 mm, 9 mm and ended with a 10 mm reamers, while the other 6 were prepared for a double bundle ACL reconstruction in which 7 mm reamer for the AM tunnel and 6 mm reamer for the PL tunnel were used. After drilling, changes of lengths and thicknesses of anterior horns of the lateral menisci were recorded.ResultsBefore drilling, the groups were homogenous for the lateral menisci dimensions. After drilling, no statistically significant difference was noticed between the two groups. However, in single bundle group, 2 anterior horns width injury (1.44 mm and 2.13 mm) with the 9 mm reamer and 3 anterior horns width injury (2.51 mm, 3.55 mm and 4.28 mm) with the 10 mm reamer were recorded. However in double bundle group a single anterior horn width injury (2.82 mm) was recorded.ConclusionUsing a greater size reamer in single bundle reconstruction, causes a relatively higher risk of lateral meniscal anterior root injury. Lateral meniscus stability should be examined arthroscopically after reaming with large reamers.
Background: Many studies in the literature focused on the proximal geometry of the femur using cadaveric samples, X-rays or computed tomography, demonstrated substantial differences in the proximal femoral geometry in different patient groups. Many radiological parameters have been introduced in the literature to aid in diagnosis and surgical interventions. Objectives: We aimed to assess the diameter of the femoral head fovea capitis in both genders with different age groups and to record their variant configurations. Patients and Methods: Six-hundred true pelvis anteroposterior radiographs of patients were divided into three different age groups.
Background: Bursitis of the snapping scapula is commonly a misdiagnosed problem. Extracorporeal shockwave therapy (ESWT) has been used successfully in the treatment of many chronic inflammatory conditions. The aim of this study was to assess and compare the effectiveness of ESWT in the treatment of scapulothoracic bursitis with the outcome of corticosteroid injection. Methods: Using the randomized controlled trials 43 patients with scapulothoracic bursitis were divided into two groups. Group 1 (n ¼ 22) received three sessions of ESWT. Group 2 (n ¼ 21) received a single local injection of 80 mg of methylprednisolone. Visual analogue scale (VAS) scores were recorded at each follow-up, whereas the level of satisfaction was evaluated using the Roles and Maudsley criteria. Results: In group 1, the average VAS scores after 1, 2, 3, and 6 months were 39, 30, 27, and 16, respectively, whereas, in group 2, the average VAS scores were 46, 44, 35, and 36, respectively. There was no statistical significance between the two groups in the first and second months. However, after 3 and 6 months, group 1 revealed lower average VAS scores compared to that of the second group with p-values (0.012 and 0.001), respectively. Roles and Maudsley criteria showed that first group patients were 46% excellent, 36% good, 14% acceptable, and 4% had poor results. However, second group patients were 24% excellent, 33% good, 19% acceptable, and 24% had poor results. Conclusion: We believe that ESWT is a beneficial and trustable method of treatment and can be strongly recommended in painful cases of scapulothoracic bursitis.
ObjectiveThe aim of this study was to assess the safety and stability of our novel anatomical patella plate and to compare its stability with tension band-wire technique.MethodsA total of 12 cadaveric preserved knees (six right and six left patellae) with close patellar size were chosen to form two groups of six samples. Each group received either plate or tension band-wiring fixation for an experimentally created patella fracture. Cyclic load of an average of 350 N was applied for all specimens and after accomplishing 50 cycles the displacements of all fracture edges were recorded.ResultsAfter completing 50 cycles in each group, the average fracture edges displacement measured in the plate group was 1.98 ± 0.299 mm, whereas the average fracture edges displacement measured in the tension band-wire group was 2.85 ± 0.768 mm (p = 0.016).ConclusionIn the operative treatment of displaced transverse patellar fractures, the strength of fixation obtained by titanium curved plates is highly stronger when compared to the fixation with a tension band-wire technique. Fixation with titanium curved plates provides satisfactory stability at the fracture site which allow withstanding the cyclic loads during the postoperative rehabilitation.
A case of a bilateral simultaneous traumatic obturator dislocation of both hip joints in an 18-year-old young man following a traffic accident is presented. We reduced the dislocated femoral heads immediately under general anesthesia followed by passive and active exercises and early full-weight bearing mobilization. After 5 years, the result was excellent.
Nailing of tibial shaft fractures is considered the gold standard surgical method by many surgeons. The aim of this retrospective study was to investigate and compare the clinical outcome of tibial shaft fractures treated with intramedullary nails compressed by proximal tube and conventional intramedullary interlocking nails. Fifty-seven patients with tibial shaft fractures, treated with intramedullary nails compressed by proximal tube (n = 32) and the conventional interlocking nails (n = 25), were reviewed. All fractures except for one were united without any additional surgical intervention in the proximal compression tube nail group, whereas in the conventional interlocking nail group, six patients needed dynamization surgery (p = 0.005) and three cases of nonunion were recorded. In the proximal compression tube nail group, faster union occurred in 20 ± 2 (16–24) weeks (mean ± SD; range) without failure of locking screws and proximal nail migration, whereas in the conventional interlocking nail group, union occurred in 22 ± 2.5 (17–27) weeks (p = 0.001) with two failures of locking screws and two proximal nail migration. The proximal compression tube nail system is safer than the conventional nailing methods for the treatment for transverse and oblique tibial shaft fractures with a less rate of nonunion, proximal locking screw failure and proximal nail migration.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.