Ankylosing spondylitis (AS) is a chronic inflammatory disease, which typically begins in early decades of life with primarily axial joints involvement. This disease rarely affects patients older than 50 years of age. The aim of this study was to compare and evaluate the demographic, clinical, and laboratory features of late onset and early onset AS patients who were followed up in a single rheumatology center. A total of 339 patients who have been diagnosed with AS according to modified New York criteria were included in the study. The patients whose initial symptoms were observed after 50 years of age were accepted as late onset AS. Out of 339 patients, 27 (7.9%) were diagnosed as late onset AS and 312 (92.3%) patients were evaluated as early onset AS. Of 27 late onset patients, 10 were male and 17 were female. Delay in the diagnosis was 5.8 years for early onset AS, while it was 3.8 years for late onset AS (p = 0.001). Higher levels of acute phase reactants and more methotrexate (MTX) use were detected in early onset AS patients compared to late onset AS (p = 0.001, p = 0.007, respectively). Statistically, there was no difference between these two groups, with regard to disease clinical activity indexes, anthropometric measurement parameters, uveitis and peripheral joint involvement. In this study, we showed that early and late onset AS patients may present with different clinical, genetic, and laboratory features. Late onset AS patients are characterized with lower human leukocyte antigen-B27 sequence, less inflammatory sign, delayed diagnosis, and less MTX and anti-tumor necrosis factor alpha drug usage.
Background:Proximal locking screw deformation and screw fracture is a frequently seen problem for femur interlocking nailing that affects fracture healing. We realized that there is lack of literature for the right level for the proximal locking screw. We investigated the difference of locking screw bending resistance between the application of screws on different proximal femoral levels.Materials and Methods:We used a total of 80 proximal locking screws for eight groups, 10 screws for each group. Three-point bending tests were performed on four types of screws in two different trochanteric levels (the lesser trochanter and 20 mm proximal). We determined the yield points at three-point bending tests that a permanent deformation started in the locking screws using an axial compression testing machine.Results:The mean yield point value of 5 mm threaded locking screws applied 20 mm proximal of lesser trochanter was 1022 ± 49 (range 986–1057) (mean ± standard deviation, 95% confidence interval). On the other hand, the mean yield point value of the same type of locking screws applied on the lesser trochanteric level was 2089 ± 249 (range 1911–2268). Which means 103% increase of screw resistance between two levels (P = 0.000). In all screw groups, on the lesser trochanter line we determined 98–174% higher than the yield point values of the same type of locking screws in comparison with 20 mm proximal to the lesser trochanter (P = 0.000).Conclusion:According to our findings, there is twice as much difference in locking screw bending resistance between these two application levels. To avoid proximal locking screw deformation, locking screws should be placed in the level of the lesser trochanter in nailing of 1/3 middle and distal femur fractures.
Nailing of tibial shaft fractures is considered the gold standard surgical method by many surgeons. The aim of this retrospective study was to investigate and compare the clinical outcome of tibial shaft fractures treated with intramedullary nails compressed by proximal tube and conventional intramedullary interlocking nails. Fifty-seven patients with tibial shaft fractures, treated with intramedullary nails compressed by proximal tube (n = 32) and the conventional interlocking nails (n = 25), were reviewed. All fractures except for one were united without any additional surgical intervention in the proximal compression tube nail group, whereas in the conventional interlocking nail group, six patients needed dynamization surgery (p = 0.005) and three cases of nonunion were recorded. In the proximal compression tube nail group, faster union occurred in 20 ± 2 (16–24) weeks (mean ± SD; range) without failure of locking screws and proximal nail migration, whereas in the conventional interlocking nail group, union occurred in 22 ± 2.5 (17–27) weeks (p = 0.001) with two failures of locking screws and two proximal nail migration. The proximal compression tube nail system is safer than the conventional nailing methods for the treatment for transverse and oblique tibial shaft fractures with a less rate of nonunion, proximal locking screw failure and proximal nail migration.
To avoid locking screw deformation, high threaded screws must not be used as locking screws. In cases of unreliable patients, 5-mm low threaded screws should not be used in the nailing of comminuted or oblique femur shaft fractures. All 5-mm unthreaded screws and 5.5-mm low threaded stainless steel screws can be used safely in full weight-bearing conditions of unreliable patients.
An anti-rotational novel nail is superior to the conventional interlocking nail in terms of maximum inter-fragmentary rotational and axial stabilities in complex and comminuted femur shaft fractures.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.