Cataract surgery with the AcrySof ReSTOR SA60D3 IOL provided good, stable distance and near visual acuities over a 3-year follow-up, leading to low spectacle independence and high patient satisfaction.
Levels of intraocular straylight log(s) were significantly lower for both types of IOL than in age-matched subjects from the normal population. The mean level of intraocular straylight 6 months postoperatively was higher in patients with an AcrySof ReSTOR SA60D3 IOL than in patients with a monofocal AcrySof SA60AT IOL. Implantation of the former IOL would therefore result in a smaller gain in contrast sensitivity and a smaller reduction in glare and halos than implantation of the latter IOL.
In patients with a history of implantation of an iris-claw pIOL for the correction of myopia, cataract surgery combined with explantation of the pIOL yielded acceptable predictability of the postoperative SE and minimal loss of ECD, resulting in a gain in BCVA.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.