A distance 9 cm from the tip of the coccyx is a reasonable starting landmark for in-office blind PNE. However, given the variability in coccyx length, caution should be taken; also, sensory-motor response is necessary to confirm proper placement.
The portable bladder scanner accurately measures PVR in patients with pelvic organ prolapse and could be considered as an alternative to catheterized assessment. However, stage III/IV prolapse is associated with increased bladder scanner error, which should be considered when determining appropriate candidates for bladder scanner PVR assessment.This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
Robotic Burch colposuspension can be completed in a safe and effective manner and should be considered as an option for patients in whom an anti-incontinence procedure is indicated and who are already undergoing robotic surgery.
Aims
The objective of this study was to investigate sacral electrical stimulation (SES) and gastric electrical stimulation (GES) by comparing upper and lower gastrointestinal (GI) and genitourinary (GU) symptoms and quality of life, before treatment and in the long term after treatment. We hypothesized that dual-device treatment would greatly improve upper and lower gastrointestinal and genitourinary symptoms, as well as quality of life.
Methods
Fifty-four patients who underwent dual-device treatment (GES and SES) were enrolled in this study. Patients who had surpassed 24 months since the second-device insertion were included. Patients were evaluated before and after both devices were implanted and given a symptom questionnaire regarding their upper GI, lower GI, and GU symptoms and their quality of life.
Results
With combined treatment, a statistically significant improvement was seen in upper GI, lower GI, and GU symptoms and quality of life. However, fecal incontinence and fecal urgency improvements did not reach statistical significance, likely due to the small sample size.
Conclusion
The implantation of two stimulators appears to be safe and effective to improve patients’ quality of life for those with upper GI symptoms, bowel problems, and bladder dysfunction.
SUMMARYThis study sought to investigate whether isolated abnormal strict morphology (<5% normal forms) and very low strict morphology (0-1% normal forms) affects pregnancy rates in intrauterine insemination (IUI). This was a retrospective study performed at an Academic Medical Center/Reproductive Medicine Center. Four hundred and eight couples were included for 856 IUI cycles. 70 IUI cycles were performed in couples with abnormal strict morphology and otherwise normal semen parameters. Outcomes were measured as clinical pregnancy rate per IUI cycle as documented by fetal heart activity on maternal ultrasound. Clinical pregnancy rate did not significantly differ between the group with abnormal strict morphology [11/70 (15.7%)] and the normal morphology group [39/281 (13.9%)]. Additionally, there was no significant difference between the pregnancy rate in the abnormal morphology group compared to that of our overall institutional IUI pregnancy rate [145/856 (16.9%)]. Furthermore, there was no significant difference between pregnancy rate in the very low morphology group [3/14 (21.4%)] compared to those with normal morphology or the overall IUI pregnancy rate. Patients with isolated abnormal strict morphology have clinical pregnancy rates similar to those with normal morphology for IUI. Even in those with very low normal forms, consideration of IUI for assisted reproduction should not be excluded.
Based on CT measurements, the aorta-sacral promontory distance is decreased in elderly and hypertensive patients. Heavier patients have an increased aorta-sacral promontory distance. These potential anatomical variants should be considered before operating in the presacral space.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.