The aim of this study was to compare mandibular advancement device (MAd) therapy and continuous positive airway pressure (CPAP) for obstructive sleep apnoea/hypopnoea syndrome (OSAHS) after one-night polysomnographic (PSG) titration of both treatments.59 with MAd (p,0.001). Positive and negative predictive values of MAd titration PSG for treatment success were 85% and 45%, respectively. Both treatments significantly improved subjective and objective sleepiness, cognitive tests and HRQoL. The reported compliance was higher for MAd (p,0.001) with .70% of patients preferring this treatment. These results support titrated MAd as an effective therapy in moderately sleepy and overweight OSAHS patients. Although less effective than CPAP, successfully titrated MAd was very effective at reducing the AHI and was associated with a higher reported compliance. Both treatments improved functional outcomes to a similar degree. One-night titration of MAd had a low negative predictive value for treatment success.
The aim of this cross-sectional study was to evaluate the frequency of type-2 diabetes and impaired glucose tolerance (IGT) in a large clinic-based male population presenting various degrees of obstructive sleep apnoea syndrome (OSAS) and to analyse the relationship between OSAS and glucose-insulin metabolism.Male patients (n=595) with suspected OSAS underwent both nocturnal polysomnography and a 2-h oral glucose-tolerance test with measurements of fasting and postload blood glucose and plasma insulin. Insulin sensitivity was evaluated by the ratio of fasting glucose to fasting insulin.OSAS was diagnosed in 494 patients, while 101 patients were nonapnoeic snorers. Type-2 diabetes was present in 30.1% of OSAS patients and 13.9% of nonapnoeic snorers. IGT was diagnosed in 20.0% of OSAS patients and 13.9% of nonapnoeic snorers. Fasting and postload blood glucose increased with severity of sleep apnoea. Insulin sensitivity decreased with increasing severity of sleep apnoea. In addition to body mass index and age, the apnoea/hypopnoea index independently influenced postload blood glucose and insulin sensitivity.The authors conclude that in a clinic-based sample of patients, obstructive sleep apnoea syndrome is associated with a high frequency of type-2 diabetes and impaired glucose tolerance. The relationship between sleep-disordered breathing and impaired glucose-insulin metabolism is independent of obesity and age. Eur Respir J 2003; 22: 156-160.
Endothelial dysfunction is involved in vascular complications of obstructive sleep apnea (OSA). In this study, circulating microparticles (MPs) from patients with OSA-induced nocturnal desaturations were characterized and their effects on endothelial function were evaluated. Two age-matched groups of patients undergoing polysomnography for OSA were compared: 35 desaturators with a 3% oxyhemoglobin desaturation index (ODI) > or = 10 events per hour of sleep and 27 nondesaturators with ODI <10 events per hour. MPs were characterized by flow cytometry and then either used to treat in vitro human endothelial cells or to study endothelial function in mice. Circulating MPs did not differ between groups, but MPs from granulocytes and activated leukocytes (CD62L(+)) were found at higher levels in desaturators. In vitro, MPs from desaturators reduced endothelial nitric oxide (NO) production by enhancing phosphorylation of endothelial NO synthase at the site of inhibition and expression of caveolin-1. CD62L(+) MPs positively correlated with ODI. Endothelial NO production negatively correlated with both CD62L(+) MPs and ODI. MPs from desaturators increased expression of endothelial adhesion molecules including E-selectin, ICAM-1 and ITGA5, and cyclooxygenase 2. Moreover, injection of MPs from desaturators into mice impaired endothelium-dependent relaxation in aorta and flow-induced dilation in small mesenteric arteries. This study demonstrates an association between endothelial dysfunction and increased circulating levels of CD62L(+) MPs. This may initiate atherogenic processes in patients with OSA and severe nighttime hypoxia.
The aim of this study was to investigate in a large population of patients with obstructive sleep apnoea and on long-term treatment with continuous positive airway pressure (CPAP) the patients' perception of symptomatic improvement, side-effects and quality of life. Questionnaires were mailed via local respiratory homecare associations to 5,339 French patients who had been treated at home for at least 6 months with CPAP machines and who continued their treatment. In total, 3,225 questionnaires were analysable. More than 80% of the responding patients reported that CPAP treatment had greatly improved their symptoms. Despite discomfort related to nasal problems and excess noise from the blower, the mean rate of use for the whole population was 6 h 36 min+/-2 h 15 min. The perceived health evaluated by the Nottingham Health Profile was good (mean score <50) for at least 75% of the patients in each dimension explored. The perceived health was significantly related to the improvement in symptoms, the overall satisfaction and the objective compliance. This retrospective study indicates that patients who continued continuous positive airway pressure treatment for more than 6 months felt a great improvement in their symptoms, were satisfied with the treatment and had a relatively good perception of their health.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.