The impact of the Tobacco Heating System 2.2 (THS 2.2) on indoor air quality was evaluated in an environmentally controlled room using ventilation conditions recommended for simulating "Office", "Residential" and "Hospitality" environments and was compared with smoking a lit-end cigarette (Marlboro Gold) under identical experimental conditions. The concentrations of eighteen indoor air constituents (respirable suspended particles (RSP) < 2.5 μm in diameter), ultraviolet particulate matter (UVPM), fluorescent particulate matter (FPM), solanesol, 3-ethenylpyridine, nicotine, 1,3-butadiene, acrylonitrile, benzene, isoprene, toluene, acetaldehyde, acrolein, crotonaldehyde, formaldehyde, carbon monoxide, nitrogen oxide, and combined oxides of nitrogen) were measured. In simulations evaluating THS 2.2, the concentrations of most studied analytes did not exceed the background concentrations determined when non-smoking panelists were present in the environmentally controlled room under equivalent conditions. Only acetaldehyde and nicotine concentrations were increased above background concentrations in the "Office" (3.65 and 1.10 μg/m(3)), "Residential" (5.09 and 1.81 μg/m(3)) and "Hospitality" (1.40 and 0.66 μg/m(3)) simulations, respectively. Smoking Marlboro Gold resulted in greater increases in the concentrations of acetaldehyde (58.8, 83.8 and 33.1 μg/m(3)) and nicotine (34.7, 29.1 and 34.6 μg/m(3)) as well as all other measured indoor air constituents in the "Office", "Residential" and "Hospitality" simulations, respectively.
An LC/MS/MS method is presented for the determination of hydrogen cyanide in cigarette mainstream smoke. Cyanide is derivatized with 2,3-naphthalenedicarboxaldehyde and taurine to form a benzo[f]isoindole derivative, which is then analyzed by LC/MS/MS. Isotopic KCN (K13C15N) was used as an internal standard. The regression equation was linear within the range 2.4331 ng/mL for cyanide with a correlation coefficient >0.999. The LOD was calculated as 4.1 ng/cigarette. The influence of the sodium hydroxide trapping solution concentration on the results is discussed. A 1 M solution showed the best results in terms of sample stability and trapping efficiency. The method proved to be robust, reliable, and more selective than current methods, making it a logical choice for determination of total cyanide in cigarette smoke.
Highlights SWATH-MS/MS analysis of artificial colours and illegal dyes in spices. Qualitative validation with forty-one compounds using matrix-matched samples. Application to spice and spice blends purchased in local markets. Sudan I, Sudan IV, Bixin (E160b) and Ponceau 4R (E124) identified in samples.
Ammonia in cigarette mainstream smoke was quantified by LC-MS/MS after derivatization. Two different reagents, fluorescamine and dansyl chloride, were investigated, but only the latter gave stable derivatives; therefore, it was considered the most appropriate choice. Smoke samples were collected on a Cambridge filter pad followed by an impinger containing a solution of hydrochloric acid. Ammonia was then derivatized with a 18.5 mM solution of dansyl chloride in acetonitrile at 70 °C for 30 min in a vial with the internal standard, (15)ND(4)Cl. The resulting derivative was analyzed by LC-MS/MS detection with an atmospheric pressure chemical ionization (APCI) interface in the positive ionization mode using multiple-reaction monitoring (MRM). Good linearity was obtained in the concentration range of 0.02-1.65 μg/mL (r(2) ≥ 0.999), and the limit of detection (LOD) was established at 0.006 μg/mL. This method has the advantage of being sensitive, efficient, and reliable and is not hindered by interferences from the sample matrix. It should thus be considered a reference method of choice for the determination of ammonia in smoke.
Studies in environmentally controlled rooms have been used over the years to assess the impact of environmental tobacco smoke on indoor air quality. As new tobacco products are developed, it is important to determine their impact on air quality when used indoors. Before such an assessment can take place it is essential that the analytical methods used to assess indoor air quality are validated and shown to be fit for their intended purpose. Consequently, for this assessment, an environmentally controlled room was built and seven analytical methods, representing eighteen analytes, were validated. The validations were carried out with smoking machines using a matrix-based approach applying the accuracy profile procedure. The performances of the methods were compared for all three matrices under investigation: background air samples, the environmental aerosol of Tobacco Heating System THS 2.2, a heat-not-burn tobacco product developed by Philip Morris International, and the environmental tobacco smoke of a cigarette. The environmental aerosol generated by the THS 2.2 device did not have any appreciable impact on the performances of the methods. The comparison between the background and THS 2.2 environmental aerosol samples generated by smoking machines showed that only five compounds were higher when THS 2.2 was used in the environmentally controlled room. Regarding environmental tobacco smoke from cigarettes, the yields of all analytes were clearly above those obtained with the other two air sample types.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.