There is a need for standardization of radiostereometric (RSA) investigations to facilitate comparison of outcome reported from different research groups. In this document, 6 research centers have agreed upon standards for terminology, description and use of RSA arrangement including radiographic set-up and techniques. Consensus regarding minimum requirements for marker stability and scatter, choice of coordinate systems, and preferred way of describing prosthetic micromotion is of special interest. Some notes on data interpretation are also presented. Validation of RSA should be standardized by preparation of protocols for assessment of accuracy and precision. Practical issues related to loading of the joint by weight bearing or other conditions, follow-up intervals, length of follow-up, radiation dose, and the exclusion of patients due to technical errors are considered. Finally, we present a checklist of standardized output that should be included in any clinical RSA paper.This document will form the basis of a detailed standardization protocol under supervision of ISO and the European Standards Working Group on Joint Replacement Implants (CEN/TC 285/WG4). This protocol will facilitate inclusion of RSA in a standard protocol for implant testing before it is released for general use. Such a protocol-also including other recognized clinical outcome parameters-will reduce the risk of implanting potentially inferior prostheses on a large scale.
The purpose of this study was to develop and test a phantom model based on actual total hip replacement (THR) components to simulate the true penetration of the femoral head resulting from polyethylene wear. This model was used to study both the accuracy and the precision of radiostereometric analysis, RSA, in measuring wear. We also used this model to evaluate optimum tantalurbead configuration for this particular cup design when used in a clinical setting.A physical model of a total hip replacement ( a phantom) was constructed which could simulate progressive, three-dimensional (3-D) penetration of the femoral head into the polyethylene component of a THR. Using a coordinate measuring machine (CMM) the positioning of the femoral head using the phantom was measured to be accurate to within 7 pm. The accuracy and precision of an RSA analysis system was determined from five repeat examinations of the phantom using various experimental set-ups of the phantom. The ac-curucy of the radiostereometric analysis, in this optimal experimental set-up studied was 33 pm for the medial direction, 22 pm for the superior direction, 86 pm for the posterior direction and 55 pm for the resultant 3-D vector length. The corresponding precision at the 95% confidence interval of the test results for repositioning the phantom five times, measured 8.4 pm for the medial direction, 5.5 pm for the superior direction, 16.0 pm for the posterior direction, and 13.5 pm for the resultant 3-D vector length. This in vitro model is proposed as a useful tool for developing a standard for the evaluation of radiostereometric and other radiographic methods used to measure in vivo wear. 0 1003 Orthopaedic Research Society. Published by Elsevier Science Ltd.All rights reserved.
Abstract:We propose a novel photogrammetric method for field plot inventory, designed for simplicity and time efficiency on-site. A prototype multi-camera rig was used to acquire images from field plot centers in multiple directions. The acquisition time on-site was less than two minutes. From each view, a point cloud was generated using a novel, rig-based matching of detected SIFT keypoints. Stems were detected in the merged point cloud, and their positions and diameters were estimated. The method was evaluated on 25 hemi-boreal forest plots of a 10-m radius. Due to difficult lighting conditions and faulty hardware, imagery from only six field plots was processed. The method performed best on three plots with clearly visible stems with a 76% detection rate and 0% commission. Diameters could be estimated for 40% of the stems with an RMSE of 2.8-9.5 cm. The results are comparable to other camera-based methods evaluated in a similar manner. The results are inferior to TLS-based methods. However, our method is easily extended to multiple station image schemas, something that could significantly improve the results while retaining low commission errors and time on-site. Furthermore, with smaller hardware, we believe this could be a useful technique for measuring stem attributes in the forest.
The least squares adjustment (LSA) method is studied as an optimisation problem and shown to be equivalent to the undamped Gauss–Newton (GN) optimisation method. Three problem‐independent damping modifications of the GN method are presented: the line search method of Armijo (GNA); the Levenberg–Marquardt algorithm (LM); and Levenberg–Marquardt with Powell dogleg (LMP). Furthermore, an additional problem‐specific “veto” damping technique, based on the chirality condition, is suggested. In a perturbation study on a terrestrial bundle adjustment problem, the GNA and LMP methods with veto damping can increase the size of the pull‐in region compared to the undamped method; the LM method showed less improvement. The results suggest that damped methods can, in many cases, provide a solution where undamped methods fail and should be available in any LSA software package. Matlab code for the algorithms discussed is available from the authors.
Therapeutic Level I. See the Guidelines for Authors for a complete description of levels of evidence.
Close-range photogrammetry as a technique to acquire reality-based 3D data has, in recent times, seen a renewed interest due to developments in sensor technologies. Furthermore, the strong democratization of UAVs (Unmanned Aerial Vehicles) or drones means that close-range photogrammetry can now be used as a viable low-cost method for 3D mapping. In terms of software development, this led to the creation of many commercial black-box solutions (PhotoScan, Pix4D, etc.). This paper aims to demonstrate how the open source toolbox DBAT (Damped Bundle Adjustment Toolbox) can be used to generate detailed photogrammetric network diagnostics to help assess the quality of surveys processed by the commercial software, PhotoScan. In addition, the Apero module from the MicMac software suite was also used to provide an independent assessment of the results. The assessment is performed by the careful examination of some of the bundle adjustment metrics generated by both open source solutions. A UAV project was conducted on a historical church in the city center of Strasbourg, France, in order to provide a dataset with a millimetric level of precision. Results showed that DBAT can be used to reprocess PhotoScan projects under similar conditions and derive useful metrics from them, while Apero provides a completely independent verification of the results of commercial solutions. Overall, this paper shows that an objective assessment of photogrammetric results is important. In cases where problems are encountered in the project, this assessment method can be useful to detect errors that may not be explicitly presented by PhotoScan.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.