RSA wear measurements with or without markers in total hip arthroplasty

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

8
80
2

Year Published

2008
2008
2020
2020

Publication Types

Select...
10

Relationship

2
8

Authors

Journals

citations
Cited by 71 publications
(90 citation statements)
references
References 14 publications
8
80
2
Order By: Relevance
“…Femoral head penetration was calculated using UmRSA 1 software (v6.0, RSA Biomedical TM ). An edge-detecting ellipse algorithm in this software was used to outline the outer diameter and the opening of the metal backing of the cup [2]. The ellipse algorithm was used in conjunction with between one and five liner beads visible in consecutive radiographs to form a reference segment.…”
Section: Methodsmentioning
confidence: 99%
“…Femoral head penetration was calculated using UmRSA 1 software (v6.0, RSA Biomedical TM ). An edge-detecting ellipse algorithm in this software was used to outline the outer diameter and the opening of the metal backing of the cup [2]. The ellipse algorithm was used in conjunction with between one and five liner beads visible in consecutive radiographs to form a reference segment.…”
Section: Methodsmentioning
confidence: 99%
“…The precision for translation and rotation was expressed by the mean of the absolute value of the difference between two double examinations + t (nÀ1)0.005 9 SD Absolute value where t follows the Student's t-distribution with n À 1 degrees of freedom and 99% level of confidence. Some authors have used the expression limit of significance (LOS) [1,4,6] as an alternate way to express this precision. When a movement beyond this limit is found, an actual movement between the segments has occurred and the detected movement is larger than what can be explained by the measurement error.…”
Section: Methodsmentioning
confidence: 99%
“…The program identifies the center of the outer ellipse of the femoral head and acetabular cup with an edge detection algorithm used in conjunction with tantalum markers placed in the outer rim of the polyethylene liner. This combined measurement technique using edge detection in conjunction with marker beads was proven to have the highest precision clinically in a study by Borlin et al [4] with a conservative detectable limit for measuring wear of 80 lm.…”
Section: Methodsmentioning
confidence: 99%