Perhaps because of reduced myocardial injury, inflammation, and activation of coagulation, patients undergoing the hybrid procedure had better perioperative outcomes and satisfaction, with excellent patency at 1 year's follow-up. These promising preliminary findings warrant further investigation of this procedure.
).q RSNA, 2015 Purpose:To investigate the utility of a free-breathing ultrashort echo time (UTE) sequence for the evaluation of small pulmonary nodules in oncology patients by using a hybrid positron emission tomography (PET)/magnetic resonance (MR) imaging system and to compare the nodule detection rate between UTE and a conventional three-dimensional gradient-recalled-echo (GRE) technique.
Materials and Methods:In this HIPAA-compliant, institutional review board-approved prospective study, 82 pulmonary nodules were identified in eight patients with extrathoracic malignancies. Patients underwent free-breathing UTE and dual-echo three-dimensional GRE imaging of the lungs in a hybrid PET/MR imaging unit immediately after clinical PET/computed tomography (CT). CT was considered the reference standard for nodule detection. Two reviewers identified nodules and obtained measurements on MR images. The McNemar test was used to evaluate differences in nodule detection rate between MR techniques, and interrater agreement was assessed by using Bland-Altman plots.
Results:Mean nodule diameter 6 standard deviation was 6.2 mm 6 2.7 (range, 3-17 mm). The detection rate was higher for UTE imaging than for dual-echo GRE imaging for nodules of at least 4 mm (82% vs 34%, respectively; P , .001), with the largest difference in detection noted in the 4-8-mm nodule group (79% vs 21%, P , .001). UTE imaging displayed a higher detection rate than dual-echo GRE imaging for nodules without fluorodeoxyglucose avidity (68% vs 22%, respectively; P , .001). Interrater reliability of nodule detection with MR imaging was high (k = 0.90 for UTE imaging and k = 0.92 for dual-echo GRE imaging).
Conclusion:A free-breathing UTE sequence has high sensitivity for the detection of small pulmonary nodules (4-8 mm) and outperformed a three-dimensional dual-echo GRE technique for the detection of small, non-fluorodeoxyglucose-avid nodules.q RSNA, 2015
Systolic flow displacement calculated from conventional 2D PC-MRI in the ascending aorta correlates with future aortic growth in patients undergoing routine surveillance imaging for BAV. With a cutoff valve of 0.2, flow displacement may be used to identify a subset of patients likely to have elevated growth rates and may better risk-stratify patients with BAV for aortic disease progression than vessel diameter alone.
By enabling the quantification of this issue as never before possible, optical coherence tomography screening revealed that intraluminal saphenous vein clot is frequently found after endoscopic vein harvest. Systemic heparinization before harvest or an open carbon dioxide endoscopic vein harvest system are benign changes in practice that can significantly lessen this complication.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.