In bridge structures, concrete decks have a higher risk of damage than other components owing to the direct impact of traffic. This study aims to develop a comprehensive system for bridge inspection using passive infrared thermography (IRT). Experiments were conducted on a concrete specimen (assumed as the surface of the bridge deck) embedded artificial delaminations with different width-to-depth ratios (WTDRs). Both professional handheld IR camera (H-IRC) and a UAV mounted with an IR camera (UAV-IRC) were employed simultaneously to capture the surface temperature of the structure. The present work indicates that the passive IRT technique with an H-IRC can be used to detect delaminations located at depths of 4 cm or less from the structure surface if the WTDRs are not lesser than 1.9 for daytime and 2.5 for nighttime when testing on a sunny day. In addition, the larger the WTDR, the higher the temperature difference can be produced, thus delaminations could be observed more clearly. Furthermore, our study suggests that the concrete bridge deck inspection using passive IRT can produce appropriate results if the inspection is performed from 10:00 to 15:00 or from 19:30 to approximately 2:00 on a sunny day. Good agreement between the results obtained from tests using H-IRC and UAV-IRC was observed, which validates the application of UAV-IRC in real structure inspection.
In the present study, the overall stability of typical Korean composite caisson breakwaters that were initially designed following the conventional deterministic approach is investigated using reliability approaches. Therefore, the sensitivity of critical uncertainties regarding breakwater safety is analyzed. Uncertainty sources related to the structure, ocean conditions, and properties of the subsoil and rubble mound are considered in the reliability analysis. Sliding and overturning failures are presented as explicit equations, and three reliability methods, i.e., the mean value first-order second-moment, first-order reliability method, and Monte Carlo simulation, are applied in the evaluation process. Furthermore, the bearing capacity of the rubble mound and subsoil are analyzed using the discrete slice method conjugated with the Monte Carlo simulation. The results of this study establish that the sliding failure generally is the most frequent failure occurring among the above-mentioned overall stability failures (around 15 times more common than failures observed in the foundation). Additionally, it is found that the horizontal wave force primarily contributes to the sliding of the caisson body, whereas the friction coefficient is the main factor producing the resistance force. Furthermore, a much small probability of overturning failure implies that the overturning of a caisson around its heels uncommonly occurs during their lifetime, unlike other overall failure modes. Moreover, the failure in foundations may commonly encounter in the breakwater that has a high rubble mound structure compared with sliding mode. Particularly, the performance function of the all foundation bearing capacities presents a nonlinear behavior and positively skewed distribution when using the Monte Carlo simulation method. This phenomenon proves that simulation methods might be an appropriate approach to evaluate the bearing capacity of a breakwater foundation that can overcome several drawbacks of the conventional design approach.
In bridge structures worldwide, carbon fiber-reinforced polymer (CFRP) sheets are applied to strengthen weak components, especially concrete girders that are at a high risk of rapid degradation during the bridge’s operation owing to impacts from the superstructure’s weight and traffic loads. Regarding the thermography-based method (TM), although deteriorations in the concrete core are some of the main defects in concrete structures strengthened with CFRP, these do not receive as much attention as damage in the CFRP. Therefore, the interpretation of the structural health in terms of these defects using TM is still unclear. The problem presented in this work addresses the quantification of delamination inside the concrete part of a specimen with a CFRP sheet installed on the surface (assumed to be the girder surface strengthened with CFRP) via step heating thermography. Additionally, the empirical thermal diffusivity of concrete girders strengthened with a CFRP sheet (CSC girder), has not been provided previously, is proposed in the present study to predict delamination depths used for field investigations. Moreover, the effect of the CFRP sheet installed on the structure’s surface on the absolute contrast of delamination is clarified. Finally, advanced post-processing algorithms, i.e., thermal signal reconstruction and pulsed phase thermography, are applied to images obtained with step heating thermography to enhance the visibility of delamination in CSC girders.
While the container crane is an important part of daily port operations, it has received little attention in comparison with other infrastructures such as buildings and bridges. Crane collapses owing to earthquakes affect the operation of the port and indirectly impact the economy. This study proposes fragility analyses for various damage levels of a container crane, thus enabling the port owner and partners to better understand the seismic vulnerability presented by container cranes. A large number of nonlinear time-history analyses were applied for a three-dimensional (3D) finite element model to quantify the vulnerability of a Korean case-study container crane considering the uplift and derailment behavior. The uncertainty of the demand and capacity of the crane structures were also considered through random variables, i.e., the elastic modulus of members, ground motion profile, and intensity. The results analyzed in the case of the Korean container crane indicated the probability of exceeding the first uplift with or without derailment before the crane reached the structure’s limit states. This implies that under low seismic excitation, the crane may be derailed without any structural damage. However, when the crane reaches the minor damage state, this condition is always coupled with a certain probability of uplift with or without derailment. Furthermore, this study proposes fragility curves developed for different structural periods to enable port stakeholders to assess the risk of their container crane.
This study investigates the system stability of breakwater foundations subjected to earthquakes from a probabilistic point of view. A fully probabilistic approach, i.e., a combination of the Monte Carlo simulation and Bishop’s simplified method, has been developed to evaluate the system failure probability of foundation damage, one of the prevailing failures encountered during earthquakes. Twelve sections of perforated caisson breakwaters located around Korea were chosen as case studies. First, the reliability analysis was performed for all the breakwaters at existing conditions; then, the calibration process involving the estimation of load and resistance factors was conducted for 12 breakwaters at three levels of the target reliability index. As the performance function, used in the stability analysis of breakwater foundations, is defined based on an implicit shape with a high-dimensional space of variables, the calibration process of load and resistance factors becomes cumbersome and complicated. Therefore, this study has proposed a sensitivity analysis to be implemented prior to the calibration process to elicit the effects of variables on the stability of each breakwater, which, thereafter, effectively directs the calibration process. The results of this study indicate that the failures in the foundation of breakwaters frequently occur in different modes. Therefore, the failure probability should be estimated considering all possible failure modes of the foundation. The sensitivity results elucidate that the soil strength parameters are the dominant variables, contributing to the stability of foundations, whereas the seismic coefficient presents the negative effect, causing the insecurity of breakwaters. In particular, the deadweights, though directly contributing to the seismic forces, show a small effect on the stability of foundations. The calibration shows that the load factors slightly vary with an increase in the target reliability index and set 1.10 for three safety levels. In contrast, the resistance factor exhibits an inverse relationship with the specified reliability index. Especially when the load factor equals 1.10, the resistance factors are 0.90, 0.85, and 0.80, corresponding to the reliability index of 2.0, 2.5, and 3.0, respectively. Eventually, it is proved that the sensitivity analysis prior to the calibration process makes the procedure more efficient. Accordingly, the iteration of simulation execution is diminished, and the convergence is quickly accomplished.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.