The addition of EEP may increase antibacterial properties without negatively modifying the mechanical properties of conventional GIC.
To investigate the levels of seven elements using an inductively coupled plasma-mass spectrometry (ICP-MS) method in rat organs after the implantation of Micro Mega Mineral Trioxide Aggregate (MM-MTA), Bioaggregate (BA) and Biodentine (BD) materials. MM-MTA, BA and BD were implanted into the subcutaneous tissue of 15 Wistar albino rats; three control animals had no operation. After 45 days, the rats were sacrificed and their brains, kidneys and livers were removed. The ICP-MS analysis was used to determine trace elements. Data were analysed using the Kruskal-Wallis and Connover post hoc tests. There was no significant difference between the control groups and the MM-MTA, BA and BD groups according to the concentration of aluminum, calcium, arsenic and lead in the rats' organs. Beryllium was not detected in all tissue samples. Chromium levels of these materials were higher than the control group in brain and kidney samples (P = 0.038 and P = 0.037); magnesium levels were higher than the control group in kidney and liver samples (P = 0.030 and P = 0.008). MM-MTA, BA and BD were nontoxic according to trace element levels in brain, kidney and liver samples of rats. Further investigation is required to understand the systemic effects of these materials.
The aim of this study was to evaluate the effectiveness of two retreatment techniques, in terms of the operating time and scanning electron microscopy (SEM) results, in removing three different root canal sealers from root canals that were previously filled with gutta-percha. Sixty extracted single-rooted human premolars were divided into three groups and filled with iRoot SP, MM Seal, and AH Plus sealers, along with gutta-percha, through a lateral compaction technique. Root canal fillings of the samples were removed by ESI ultrasonic tips or R-Endo files. The time to reach the working length was recorded. Longitudinally sectioned samples were examined under SEM magnification. Each picture was evaluated in terms of the residual debris. Data were statistically analyzed with the Kruskall-Wallis test. No statistically significant differences were found in terms of operating time (p>0.05). Significant differences in the number of debris-free dentinal tubules were found among the root canal thirds, but this finding was not influenced by the experimental group (p<0.05). Resin sealer tags were observed inside the dentinal tubules in the MM Seal group. Under the conditions of this study, it may be established that there was no difference among the sealers and retreatment techniques.
The aim of this study was to evaluate the efficiencies of the self-adjusting file (SAF) system, passive ultrasonic irrigation (PUI), and conventional irrigation (CI) in removing calcium hydroxide (CH) from root canals. Fifty-one mandibular premolars were used. After root canals were instrumented and filled with a CH paste, 45 teeth were randomly assigned to three experimental groups according to CH removal technique: SAF system, PUI, or CI. The remaining 6 teeth served as positive and negative controls. All samples were evaluated by scanning electron microscopy (SEM) and scored. None of the techniques removed CH completely. However, results at coronal, middle and apical thirds showed that PUI technique was significantly more effective than SAF and CI in removing CH dressing residues from root canal walls.
Objectives:To evaluate effectiveness of the apical negative pressure irrigation (EndoVac), passive ultrasonic irrigation (PUI), and conventional needle irrigation (CI) systems on smear layer (SR) removal.Materials and Methods:Sixty single-rooted canines were prepared using NiTi rotary files and subjected to different irrigation regimens: EndoVac with NaOCl (Group 1) or NaOCl/EDTA (Group 2); PUI with NaOCl (Group 3) or NaOCl/EDTA (Group 4); CI with NaOCl (Group 5) or NaOCl/EDTA (Group 6). The roots were split longitudinally. SEM images were taken to evaluate the amount of residual SR.Results:In Groups 1, 3, and 5, there was no removal of SR (P > 0.05). The coronal thirds within Groups 2, 4, and 6 were cleaned completely, but the middle and the apical thirds was achieved partially or completely (P > 0.05).Conclusion:Regardless of which irrigation system was used, the use of NaOCl alone failed to remove the SR. In NaOCl/EDTA combination groups, the SR was removed partially or completely and no statistical significance. This study demonstrated that in order to remove the SR should be used EDTA solution for final irrigation in the root canal, regardless of the technique in each of the three.
The term taurodontism is derived from the Latin word tauros, for “bull,” and the Greek term odus, for “tooth,” or “bull tooth.” Taurodontism is a morpho-anatomical developmental anomaly, which is seen infrequently in teeth only. It is characterized by a deficiency in the constriction at the cement-enamel junction, with lengthened pulp chambers and apical displacement of the pulpal floor. This gives the tooth a quadrilateral or cylindrical look. This report presents a case of multiple bilateral taurodontism and the successful endodontic treatment of the tooth that had hypertaurodontism. A male patient was referred to the endodontic clinic with decayed left maxillary first molar. Hypertaurodontism was confirmed after clinical and radiographic examination. Panaromic X-rays revealed that all of the patient's molar teeth were taurodontic. Taurodontism offers challenges to the practitioner during shaping and disinfection and at the time of filling the root canals.
Following root canal treatment, sealers may contact periapical tissue. The purpose of this study was to evaluate the systemic toxic effects of epoxy resin-based sealers (AH Plus and Obtuseal). Inductively coupled plasma-mass spectrometry (ICP-MS) was used to measure levels of trace elements (beryllium, magnesium, aluminium, calcium, chromium, arsenic and lead) in the brain, kidney and liver of rats. Twenty sterilized polyethylene tubes were then filled with AH Plus and Obtuseal and implanted into the dorsal subcutaneous tissue of 10 rats; three unoperated animals were used as a control group. After 45 days, the rats were sacrificed by cervical dislocation following anaesthesia, and brains, kidneys and livers were removed from all experimental animals. ICP-MS analysis was used to determine levels of trace elements. Data were analysed using KruskalWallis and Connover post hoc tests. No significant differences were found in aluminium and calcium levels, but brains, kidneys and livers showed significantly higher amounts of magnesium and chromium than the corresponding controls. In the kidney and liver samples, arsenic levels were found to be higher than in the control group. Lead was detected at higher levels only in liver samples from the AH Plus group. Beryllium was not detected in any organ. It was concluded that AH Plus and Obtuseal release minimal quantities of trace elements when in contact with subcutaneous tissue, and further studies are needed to understand the systemic effects of these materials.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.