Prevention of industrial machineries against internal and external faults is mandatory for uninterrupted operation. Identifying the exact faults or anomalies in the system and predicting the machine’s health continuously is an essential preventive measure. To realize the protection system, pre-analysis of various faults under different load conditions is mandatory and hence, paper analysis a critical fault “Inter turn fault” in the wound rotor induction machine (WRIM). Inter turn fault is developed experimentally in 2.2 kW WRIM with 20 percent of internal windings shorted under different load conditions (0 to 1 per unit load). Obtained results are analysed for various electrical and mechanical parameters, and the faulty effects are revealed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.