In this research, new coated carbon electrodes were constructed and used for the determination of Sildenafil citrate (SILC) drug. The electrodes were constructed by preparing ion-pair for (SILC) with phosphotungstic acid (PTA) or phosphomolybdic (PMA) acid using dibutyl phthalate (DBP) as a plasticizer. These electrodes showed good sensitivity towards SILC with linear range of (1.010-7-1.010-2) M, correlation coefficient, (0.9990), the life time (120) days, optimum temperature range (23-65) o C and optimum pH range (2-5) for both electrodes, limit of detection (5.05510-8 and 5.11610-8) M, slope (57.29 and 59.10) mV/decadefor SILC-PTA and SILC-PMA electrodes respectively. These electrodes were successfully applied for determination of SILC in pure and pharmaceutical preparation form(tablets) with recovery of not less than 98%.
In this research, new graphite paste electrodes modified with silicon dioxide (SiO2) nano particle are constructed and used for the determination of Viagra drug (Sildenafil citrate, SILC). The electrodes are constructed by preparing ion-pair for (SILC) with phosphotungstic acid (PTA) or phosphomolybdic (PMA) acid using dibutyl phthalate (DBP) as a plasticizer. These electrodes show good sensitivity towards SILC with linear range of (1.0´10-7-1.0´10-2) M, correlation coefficient, (0.9990) and the life time (120) days for both electrodes, limit of detection (5.177´10-8 and 5.026´10-8) M, optimum temperature range (23-50 and 23-65)oC , slope (57.33 and 58.01) mV/decade and optimum pH range (2-6 and 2-5), for SILC-PTA and SILC-PMA electrodes respectively. These electrodes were successfully applied for determination of SILC in pure and pharmaceutical preparation form (tablets) with recovery of not less than 98% .
In this research, new graphite paste electrodes modified with silicon dioxide (SiO2) nano particle are constructed and used for the determination of Viagra drug (Sildenafil citrate, SILC). The electrodes are constructed by preparing ion-pair for (SILC) with phosphotungstic acid (PTA) or phosphomolybdic (PMA) acid using dibutyl phthalate (DBP) as a plasticizer. These electrodes show good sensitivity towards SILC with linear range of (1.0´10-7-1.0´10-2) M, correlation coefficient, (0.9990) and the life time (120) days for both electrodes, limit of detection (5.177´10-8 and 5.026´10-8) M, optimum temperature range (23-50 and 23-65)oC , slope (57.33 and 58.01) mV/decade and optimum pH range (2-6 and 2-5), for SILC-PTA and SILC-PMA electrodes respectively. These electrodes were successfully applied for determination of SILC in pure and pharmaceutical preparation form (tablets) with recovery of not less than 98% .
http://dx.doi.org/10.25130/tjps.24.2019.109
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.