Adenovirus, a waterborne pathogen responsible for causing bronchitis, pneumonia, and gastrointestinal infections, is highly resistant to UV disinfection and therefore drives the virus disinfection regulations set by the U.S. Environmental Protection Agency. Polychromatic UV irradiation has been shown to be more effective at inactivating adenovirus and other viruses than traditional monochromatic irradiation emitted at 254 nm; the enhanced efficacy has been attributed to UV-induced damage to viral proteins. This research shows UV-induced damage to adenoviral proteins across the germicidal UV spectrum at wavelength intervals between 200 and 300 nm. A deuterium lamp with bandpass filters and UV light-emitting diodes (UV LEDs) isolated wavelengths in approximate 10 nm intervals. Sodium dodecyl sulfate polyacrylamide gel electrophoresis and image densitometry were used to detect signatures for the hexon, penton, fiber, minor capsid, and core proteins. The greatest loss of protein signature, indicating damage to viral proteins, occurred below 240 nm. Hexon and penton proteins exposed to a dose of 28 mJ/cm emitted at 214 nm were approximately 4 times as sensitive and fiber proteins approximately 3 times as sensitive as those exposed to a dose of 50 mJ/cm emitted at 254 nm. At 220 nm, a dose of 38 mJ/cm reduced the hexon and penton protein quantities to approximately 33% and 31% of the original amounts, respectively. In contrast, a much higher dose of 400 mJ/cm emitted at 261 and 278 nm reduced the original protein quantity to between 66-89% and 80-93%, respectively. No significant damage was seen with a dose of 400 mJ/cm at 254 nm. This research directly correlates enhanced inactivation at low wavelengths with adenoviral protein damage at those wavelengths, adding fundamental insight into the mechanisms of inactivation of polychromatic germicidal UV irradiation for improving UV water disinfection.
BackgroundA wide variety of specialty textiles are used in health care settings for bedding, clothing, and privacy. The ability of textiles to host or otherwise sequester microbes has been well documented; however, their reciprocal potential for liberating airborne bacteria remains poorly characterized. In response, a multi-season survey of bacterial bioaerosols was conducted in the origin and terminus of residual paths which are specifically designed to isolate soiled hospital textiles as they are moved to laundering. This survey used conventional optical particle counting which incorporated multi-channel fluorescence in conjunction with molecular phylogenetic analyses to characterize the bioaerosols liberated during soiled textile storage—immediately before and after the occupation of a modern hospital. Although outfitted with a HEPA filtration system, the number of airborne particles presenting fluorescing optical signatures consistent with airborne bacteria and fungi significantly increased in textile holding rooms soon after the hospital’s commissioning, even though these isolated residual areas rarely host personnel. The bioaerosol liberated during textile storage was characterized using Illumina MiSeq sequencing of bacterial 16S ribosomal ribonucleic acid (rRNA) genes. Gene copies recovered by quantitative PCR from aerosol collected in co-located impingers were consistent with fluorescence gated optical particle counting.ResultsThe relative abundance patterns of proximal bacterial bioaerosol were such that the air in the origin and terminus of textile storage rooms could not be differentiated once the hospital began processing soiled linens. Genes from microbes typically associating with human skin, feces, and hair—Staphylococcus, Propionibacteria, Corynebacteria, Lactobacillus, and Streptococcus spp.—dominated the aerosol abundance profiles in textile holding rooms, which were generally far less diverse than communities recovered from surfaces in patient rooms.ConclusionsThese results suggest that aerosol partitioning from the routine handling of soiled textiles can contribute to airborne exposures in the health care environment.
This work critically evaluates the current paradigm of water distribution system management and juxtaposes that with the potential benefits of employing UV irradiation, which we hope will catalyze a critical re-evaluation of the current practices in water distribution system management and spur critical research and a new way of thinking about secondary disinfection across the extent of distribution systems. Given the recent advances in UV technology and the efficacy of UV disinfection against all pathogen classes, we now see UV applications for disinfection in many aspects of consumers lives: in water coolers, dishwashers, coffee makers, and disinfection of personal items like gym bags, water bottles, and toothbrushes. Public and regulatory concern over water quality and pathogens, especially the recent interest in building plumbing, calls out for new approaches to disinfection and distribution system management. We envision a new model for secondary disinfection in water distribution systems utilizing emerging germicidal UV LED-based disinfection. UV irradiation in water treatment can achieve high levels of disinfection of all pathogens and minimize or eliminate the formation of regulated disinfection by-products. So why is UV not considered as a secondary disinfectant for distribution systems? In this paper, we lay out the logic as to the benefits and practicality of adding distributed UV treatment to assist in protection of distribution systems and protect water quality for human exposure.
The composition and metabolic activities of microbes in drinking water distribution systems can affect water quality and distribution system integrity. In order to understand regional variations in drinking water microbiology in the upper Ohio River watershed, the chemical and microbiological constituents of 17 municipal distribution systems were assessed. While sporadic variations were observed, the microbial diversity was generally dominated by fewer than 10 taxa, and was driven by the amount of disinfectant residual in the water. Overall, Mycobacterium spp. (Actinobacteria), MLE1-12 (phylum Cyanobacteria), Methylobacterium spp., and sphingomonads were the dominant taxa. Shifts in community composition from Alphaproteobacteria and Betaproteobacteria to Firmicutes and Gammaproteobacteria were associated with higher residual chlorine. Alpha- and beta-diversity were higher in systems with higher chlorine loads, which may reflect changes in the ecological processes structuring the communities under different levels of oxidative stress. These results expand the assessment of microbial diversity in municipal distribution systems and demonstrate the value of considering ecological theory to understand the processes controlling microbial makeup. Such understanding may inform the management of municipal drinking water resources.
Ongoing disease surveillance is a critical tool to mitigate viral outbreaks, especially during a pandemic. Environmental monitoring has significant promise even following widespread vaccination among high-risk populations. The goal of this work is to demonstrate molecular severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) monitoring in bulk floor dust and related samples as a proof of concept of a noninvasive environmental surveillance methodology for coronavirus disease 2019 (COVID-19) and potentially other viral diseases. Surface swab, passive sampler, and bulk floor dust samples were collected from the rooms of individuals positive for COVID-19, and SARS-CoV-2 was measured with quantitative reverse transcription-PCR (RT-qPCR) and two digital PCR (dPCR) methods. Bulk dust samples had a geometric mean concentration of 163 copies/mg of dust and ranged from nondetects to 23,049 copies/mg of dust detected using droplet digital PCR (ddPCR). An average of 89% of bulk dust samples were positive for the virus by the detection methods compared to 55% of surface swabs and fewer on the passive sampler (19% carpet, 29% polystyrene). In bulk dust, SARS-CoV-2 was detected in 76%, 93%, and 97% of samples measured by qPCR, chip-based dPCR, and droplet dPCR, respectively. Detectable viral RNA in the bulk vacuum bags did not measurably decay over 4 weeks, despite the application of a disinfectant before room cleaning. Future monitoring efforts should further evaluate RNA persistence and heterogeneity in dust. This study did not measure virus infectivity in dust or potential transmission associated with dust. Overall, this work demonstrates that bulk floor dust is a potentially useful matrix for long-term monitoring of viral disease in high-risk populations and buildings. IMPORTANCE Environmental surveillance to assess pathogen presence within a community is proving to be a critical tool to protect public health, and it is especially relevant during the ongoing COVID-19 pandemic. Importantly, environmental surveillance tools also allow for the detection of asymptomatic disease carriers and for routine monitoring of a large number of people as has been shown for SARS-CoV-2 wastewater monitoring. However, additional monitoring techniques are needed to screen for outbreaks in high-risk settings such as congregate care facilities. Here, we demonstrate that SARS-CoV-2 can be detected in bulk floor dust collected from rooms housing infected individuals. This analysis suggests that dust may be a useful and efficient matrix for routine surveillance of viral disease.
Now is an opportune time to fund and foster collaborations across sectors and geographical boundaries to enable development of best practices for drinking water (DW) microbiome research, focusing on accuracy and reproducibility of meta-omic techniques (while learning from past microbiome projects). A large-scale coordinated effort that builds on this foundation will enable the urgently needed comprehensive spatiotemporal understanding and control of DW microbiomes by engineering interventions to protect public health. This opinion paper highlights the need to initiate and conduct a large-scale coordinated DW microbiome project by addressing key knowledge gaps, and recommends a roadmap for this effort.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.