SPECTROPHOTOMETRIC DETERMINATION OF MOLYBDENUM CONTENT IN 99m Tc SOLUTION VIA Mo-TGA-KSCN COMPLEXES FORMATION. Quality of Technetium-99m solution is determined from its radiochemical, radionuclidic and chemical purity. One of the major concern about chemical purity of Tc-99m from irradiated natural molybdenum is its molybdenum content or Mo breaktrough. Spectrophotometric method is one of method that could be applied for Mo determination in Tc-99m solution. Molybdenum (V) could form a colored complexes with potassium thiocyanate (KSCN) but Molybdenum (VI) must be reduced before formed a complexes with KSCN. Thioglycolic Acid (TGA) was used as reducing agent to obtain reduced Mo (Mo(V)). A series of optimization process was carried out to find optimum condition of complex formation for analysis purposes. Optimized condition were 3 mL of 25% HCl was added into a volume of Mo sample, followed by 200 µL of 10% TGA, 1 mL of 10% KSCN, and water addition up to 10 mL total volume. The method is linear over 2 ppm to 30 ppm Mo with regression coeffisient 0.9988±0.0007. The detection limit was 0.212 ppm Mo. Color of the complex has a stability of absorbance up to 120 minutes while stored at room temperature. No significant deviation occured when 1000 ppm of oxalic acid, methyl ethyl ketone and iron added into sample solution. This complexing method is suitable for spectrophotometric determination of molybdenum content in Tc-99m solution as a part of quality control process.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.