Abstract. Hydroxyl (OH) radical reactivity (k OH ) has been measured for 18 years with different measurement techniques. In order to compare the performances of instruments deployed in the field, two campaigns were conducted performing experiments in the atmospheric simulation chamber SAPHIR at Forschungszentrum Jülich in October 2015 and April 2016. Chemical conditions were chosen either to be representative of the atmosphere or to test potential limitations of instruments. All types of instruments that are currently used for atmospheric measurements were used in one of the two campaigns. The results of these campaigns demonstrate that OH reactivity can be accurately measured for a wide range of atmospherically relevant chemical conditions (e.g. water vapour, nitrogen oxides, various organic compounds) by all instruments. The precision of the measurements (limit of detection < 1 s −1 at a time resolution of 30 s to a few minutes) is higher for instruments directly detecting hydroxyl radicals, whereas the indirect comparative reactivPublished by Copernicus Publications on behalf of the European Geosciences Union. H. Fuchs et al.: OH reactivity comparison in SAPHIRity method (CRM) has a higher limit of detection of 2 s −1 at a time resolution of 10 to 15 min. The performances of the instruments were systematically tested by stepwise increasing, for example, the concentrations of carbon monoxide (CO), water vapour or nitric oxide (NO). In further experiments, mixtures of organic reactants were injected into the chamber to simulate urban and forested environments. Overall, the results show that the instruments are capable of measuring OH reactivity in the presence of CO, alkanes, alkenes and aromatic compounds. The transmission efficiency in Teflon inlet lines could have introduced systematic errors in measurements for low-volatile organic compounds in some instruments. CRM instruments exhibited a larger scatter in the data compared to the other instruments. The largest differences to reference measurements or to calculated reactivity were observed by CRM instruments in the presence of terpenes and oxygenated organic compounds (mixing ratio of OH reactants were up to 10 ppbv). In some of these experiments, only a small fraction of the reactivity is detected. The accuracy of CRM measurements is most likely limited by the corrections that need to be applied to account for known effects of, for example, deviations from pseudo first-order conditions, nitrogen oxides or water vapour on the measurement. Methods used to derive these corrections vary among the different CRM instruments. Measurements taken with a flowtube instrument combined with the direct detection of OH by chemical ionisation mass spectrometry (CIMS) show limitations in cases of high reactivity and high NO concentrations but were accurate for low reactivity (< 15 s −1 ) and low NO (< 5 ppbv) conditions.
Abstract. The hydroxyl (OH) radical is an important oxidant in the troposphere, which controls the lifetime of most air quality- and climate-related trace gases. However, there are still uncertainties concerning its atmospheric budget, and integrated measurements of OH sinks have been valuable to improve this aspect. Among the analytical tools used for measuring total OH reactivity in ambient air, the comparative reactivity method (CRM) is spreading rapidly in the atmospheric community. However, measurement artifacts have been highlighted for this technique, and additional work is needed to fully characterize them. In this study, we present the new Mines Douai CRM instrument, with an emphasis on the corrections that need to be applied to ambient measurements of total OH reactivity. Measurement artifacts identified in the literature have been investigated, including (1) a correction for a change in relative humidity between the measurement steps leading to different OH levels, (2) the formation of spurious OH in the sampling reactor when hydroperoxy radicals (HO2) react with nitrogen monoxide (NO), (3) not operating the CRM under pseudo-first-order kinetics, and (4) the dilution of ambient air inside the reactor. The dependences of these artifacts on various measurable parameters, such as the pyrrole-to-OH ratio and the bimolecular reaction rate constants of ambient trace gases with OH, have also been studied. Based on these observations, parameterizations are proposed to correct ambient OH reactivity measurements. On average, corrections of 5.2 ± 3.2, 9.2 ± 15.7, and 8.5 ± 5.8 s−1 were respectively observed for (1), (2) and (3) during a field campaign performed in Dunkirk, France (summer 2014). Numerical simulations have been performed using a box model to check whether experimental observations mentioned above are consistent with our understanding of the chemistry occurring in the CRM reactor. Two different chemical mechanisms have been shown to reproduce the magnitude of corrections (2) and (3). In addition, these simulations reproduce their dependences on the pyrrole-to-OH ratio and on bimolecular reaction rate constants of gases reacting with OH. The good agreement found between laboratory experiments and model simulations gives us confidence in the proposed parameterizations. However, it is worth noting that the numerical values given in this study are suitable for the Mines Douai instrument and may not be appropriate for other CRM instruments. It is recommended that each group characterize its own instrument following the recommendations given in this study. An assessment of performances for the Mines Douai instrument, including a propagation of errors from the different corrections, indicates a limit of detection of 3.0 s−1 and total uncertainties of 17–25 % for OH reactivity values higher than 15 s−1 and NOx mixing ratios lower than 30 ppbv.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.