Introduction: Either cryoenergy or radiofrequency can be used during atrioventricular nodal reentrant tachycardia (AVNRT) ablation. There are still limited data comparing their respective long-term efficacy (>1 year). This study sought to compare the very long-term outcomes of AVNRT ablation using radiofrequency or cryotherapy. Methods: We retrospectively included all patients who had undergone a first AVNRT ablation in our institution between January 2010 and December 2017. The primary endpoint was recurrence of documented AVNRT. Results: The study population consisted of 409 patients (274 females; mean age, 49.9 years). Ablation was performed using cryoenergy in 260 patients and radiofrequency in 149. High acute procedural success rate (>98%) was obtained and no permanent AV block was observed using both techniques. During a mean follow-up of 3.3 ± 2.3 years, documented AVNRT recurrence occurred in 24 (9.2%) and 4 patients (2.7%) in the cryoablation (CA) and radiofrequency (RF) group, respectively. The risk of AVNRT recurrence was significantly higher in the CA group as compared with the RF group (hazard ratio [HR] = 3.7; 95% confidence interval [CI], 1.3-5.9). Most of the recurrences after CA occurred between 1-and 6-year follow-up (14/24; 58.3%), with one-third of late recurrences after 3-year follow-up. In multivariable analysis, only Koch's triangle anatomical variant was associated with AVNRT recurrence after CA (HR = 6.7; 95% CI, 2.7-16.3). Conclusion: While AVNRT recurrence rates were similar at 1 year of follow-up regardless of the energy used, long-term efficacy appeared higher after radiofrequency ablation. Strikingly, recurrences occured much later after cryotherapy compared with radiofrequency ablation.
In the post-TAVI period, our data support PPI in patients with CAVB even if paroxysmal. Our data also suggest PPI may be considered in patients with NOP-LBBB associated with either prolonged PR or HV interval.
RFA was predominantly targeted at the endocardial surface. Ventricular tachycardia recurrences were common, but few ARVC patients experienced major clinical events during follow-up. Further studies should investigate the benefit of extensive substrate ablation combined with endo-epicardial strategies.
Background
Right ventricular pacing (RVP) induces ventricular asynchrony in patients with normal QRS and increases the risk of heart failure and atrial fibrillation in long term. His bundle pacing (HBP) is a physiological alternative to RVP, and could overcome its drawbacks. Recent studies assessed the feasibility and safety of HBP in expert centers with a vast experience of this technique. These results may not apply to less experienced centers. We aim to evaluate the feasibility and safety of permanent HBP performed by physicians who are new to this technique.
Methods
We included all patients who underwent pacemaker implantation with attempt of HBP in three hospitals between September 2017 and January 2020. Indication for HBP was left to operators' discretion. All the operators were new for HBP. His bundle (HB) electrical parameters were recorded at implant, 3‐ and 12‐month follow‐up.
Results
HBP was successful in 141 of 170 patients (82.9%); selective HBP was obtained in 96 patients and nonselective HBP in 45. The mean procedure and fluoroscopy durations were 67.0 ± 28.8 min, and 7.3 ± 8.1 min (3.1 ± 4.1 Gy·cm2), respectively. The mean HB paced QRS duration was 106 ± 18 ms. The mean HB capture threshold was 1.29 ± 0.77 V and did not increase at 3‐ and 12‐month follow‐up. The ventricular lead revision was required in five patients. Our results showed a rapid technical learning allowing a high procedure success rate (89.8%) after 15 procedures.
Conclusion
HBP performed by operators new to this technique appeared feasible and safe. This should encourage HBP to be performed in patients expected to experience high RVP burden.
Aims
Left bundle branch area pacing (LBBAP) is a recent technique aiming at preservation of physiological ventricular electrical activation. Our goal was to assess mechanical synchrony parameters in relation to electrocardiographic features during LBBAP performed in routine practice.
Methods and results
From June 2020 to August 2021, all patients of our institution with permanent pacemaker implantation indication were eligible for LBBAP. A ‘qR’ pattern in V1 and a delay from pacing spike to the peak of the R-wave in V6 < 80 ms defined a successful LBBAP. Electrocardiogram and echocardiography were performed during spontaneous rhythm and LBBAP: left ventricular mechanical synchrony (LVMS) parameters using 2D Speckle tracking and interventricular mechanical delay (IVMD) were collected. LBBAP was attempted with success in 134/163 patients (82.2%). During LBBAP, the mean QRS width was 104 ± 12 ms. In patients with left bundle branch block (n = 47), LBBAP provided a significant decrease of QRS width from 139 ± 16 to 105 ± 12 ms (P < 0.001) with reduction of LVMS (53 ± 21 vs. 90 ± 46 ms, P = 0.009), and IVMD (14 ± 13 vs. 49 ± 18 ms, P < 0.001). In patients with right bundle branch block (n = 38), LBBAP led to a significant decrease of QRS width from 134 ± 14 to 106 ± 13 ms (P < 0.001) with no effect on LVMS and a reduction of IVMD (17 ± 14 vs. 50 ± 16 ms, P < 0.001).
Conclusion
LBBAP in routine practice preserved intra-ventricular mechanical synchrony in patients with narrow and RBBB QRS and improved asynchrony parameters in patients with LBBB.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.