Retinal image registration is commonly required in order to combine the complementary information in different retinal modalities. In this paper, a new automatic scheme to register retinal images is presented and is currently tested in a clinical environment. The scheme considers the suitability and efficiency of different image transformation models and function optimization techniques, following an initial preprocessing stage. Three different transformation models--affine, bilinear and projective--as well as three optimization techniques--downhill simplex method, simulated annealing and genetic algorithms--are investigated and compared in terms of accuracy and efficiency. The registration of 26 pairs of Fluoroscein Angiography and Indocyanine Green Chorioangiography images with the corresponding Red-Free retinal images, showed the superiority of combining genetic algorithms with the affine and bilinear transformation models. A comparative study of the proposed automatic registration scheme against the manual method, commonly used in the clinical practice, is finally presented showing the advantage of the proposed automatic scheme in terms of accuracy and consistency.
In this paper, an automatic method for registering multimodal retinal images is presented. The method consists of three steps: the vessel centerline detection and extraction of bifurcation points only in the reference image, the automatic correspondence of bifurcation points in the two images using a novel implementation of the self organizing maps and the extraction of the parameters of the affine transform using the previously obtained correspondences. The proposed registration algorithm was tested on 24 multimodal retinal pairs and the obtained results show an advantageous performance in terms of accuracy with respect to the manual registration.
A simplified three-dimensional Monte Carlo simulation model of in vitro tumor growth and response to fractionated radiotherapeutic schemes is presented in this paper. The paper aims at both the optimization of radiotherapy and the provision of insight into the biological mechanisms involved in tumor development. The basics of the modeling philosophy of Duechting have been adopted and substantially extended. The main processes taken into account by the model are the transitions between the cell cycle phases, the diffusion of oxygen and glucose, and the cell survival probabilities following irradiation. Specific algorithms satisfactorily describing tumor expansion and shrinkage have been applied, whereas a novel approach to the modeling of the tumor response to irradiation has been proposed and implemented. High-performance computing systems in conjunction with Web technologies have coped with the particularly high computer memory and processing demands. A visualization system based on the MATLAB software package and the virtual-reality modeling language has been employed. Its utilization has led to a spectacular representation of both the external surface and the internal structure of the developing tumor. The simulation model has been applied to the special case of small cell lung carcinoma in vitro irradiated according to both the standard and accelerated fractionation schemes. A good qualitative agreement with laboratory experience has been observed in all cases. Accordingly, the hypothesis that advanced simulation models for the in silico testing of tumor irradiation schemes could substantially enhance the radiotherapy optimization process is further strengthened. Currently, our group is investigating extensions of the presented algorithms so that efficient descriptions of the corresponding clinical (in vivo) cases are achieved.
Image registration of multimodality images is an essential task in numerous applications in three-dimensional medical image processing. Medical diagnosis can benefit from the complementary information in different modality images. Surface-based registration techniques, while still widely used, were succeeded by volume-based registration algorithms that appear to be theoretically advantageous in terms of reliability and accuracy. Several applications of such algorithms for the registration of CT-MRI, CT-PET, MRI-PET, and SPECT-MRI images have emerged in the literature, using local optimization techniques for the matching of images. Our purpose in this work is the development of automatic techniques for the registration of real CT and SPECT images, based on either surface- or volume-based algorithms. Optimization is achieved using genetic algorithms that are known for their robustness. The two techniques are compared against a well-established method, the Iterative Closest Point-ICP. The correlation coefficient was employed as an independent measure of spatial match, to produce unbiased results. The repeated measures ANOVA indicates the significant impact of the choice of registration method on the magnitude of the correlation (F = 4.968, p = 0.0396). The volume-based method achieves an average correlation coefficient value of 0.454 with a standard deviation of 0.0395, as opposed to an average of 0.380 with a standard deviation of 0.0603 achieved by the surface-based method and an average of 0.396 with a standard deviation equal to 0.0353 achieved by ICP. The volume-based technique performs significantly better compared to both ICP (p<0.05, Neuman Keuls test) and the surface-based technique (p<0.05, Neuman-Keuls test). Surface-based registration and ICP do not differ significantly in performance.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.