A collaborative multicenter study was conducted to evaluate the sensitivity, specificity, and precision of a three-step, fully automated, qualitative microparticle-based enzyme-linked immunoassay (AxSYM HIV Ag/Ab Combo; Abbott Laboratories), designed to simultaneously detect (i) antibodies against human immunodeficiency virus type 1 (HIV-1) and/or type 2 (HIV-2) and (ii) HIV p24 antigen. A significant reduction in the HIV seroconversion window was achieved by combining detection of HIV antibodies and antigen into a single assay format. For 22 selected, commercial HIV seroconversion panels, the mean time of detection with the combinedformat HIV antigen-antibody assay was reduced by 6.15 days compared to that with a similar third-generation single-format HIV antibody assay. The quantitative sensitivity of the combination assay for the p24 antigen (17.5 pg/ml by use of the p24 quantitative panel VIH SFTS96) was nearly equivalent to that of single-format antigen tests. The combination assay demonstrated sensitive (100%) detection of anti-HIV immunoglobulin in specimens from individuals in CDC stages A, B, and C and from individuals infected with different HIV-1 group M subtypes, group O, or HIV-2. The apparent specificity for hospitalized patients (n ؍ 1,938) was 99.90%. In a random population of 7,900 volunteer blood donors, the specificity (99.87%) was comparable to that of a third-generation single-format HIV antibody assay (99.92%) on the same donor specimens. In addition, the combination assay was robust to potential interfering specimens. The precision of the combination was high, with intra-and interrun variances of <9.3% for each precision panel specimen or assay control and <5.3% for the negative assay control.
The PRISM HIV antigen-antibody combination assay demonstrated a significant reduction of the window period for diagnosis of HIV infection. The assay demonstrated enhanced specificity and sensitivity along with broad subtype detection. The assay performance represents the "state-of-the art" technology for serologic blood screening of HIV infection.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.