The effects of welding conditions such as the electrode type and welding current were investigated on the microstructure and joint strength of the resistance weld of A5052 and GA590. The reaction layer formed at the joint interface was inferred to consist of Fe-Al based intermetallic compounds (IMCs) which are FeAl, FeAl2, Fe2Al5 and FeAl3 by quantitative analysis. Although the thickness of the IMCs layer decreased from the center of the nugget towards the edge of it. When the DR type electrode was used, the cross tensile force became higher than those of the joints formed with the R type one. This is because the thickness of the reaction layer formed at the nugget end of A5052 was thin in the case of the DR type electrode. Also, it was found that cross tensile force increases when the thickness of the reaction layer is thin by multiple regression analysis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.