A novel flow sensor is presented to measure the flow rate within microchannels in a real-time, noncontact and nonintrusive manner. The microfluidic device is made of a fluidic microchannel sealed with a thin polymer layer interfacing the fluidics and microwave electronics. Deformation of the thin circular membrane alters the permittivity and conductivity over the sensitive zone of the microwave resonator device and enables high-resolution detection of flow rate in microfluidic channels using noncontact microwave as a standalone system. The flow sensor has the linear response in the range of 0-150 µl/min for the optimal sensor performance. The highest sensitivity is detected to be 0.5 µl/min for the membrane with the diameter of 3 mm and the thickness of 100 µm. The sensor is reproducible with the error of 0.1% for the flow rate of 10 µl/min. Furthermore, the sensor functioned very stable for 20 hrs performance within the cell culture incubator in 37 °C and 5% CO 2 environment for detecting the flow rate of the culture medium. This sensor does not need any contact with the liquid and is highly compatible with several applications in energy and biomedical engineering, and particularly for microfluidic-based lab-on-chips, micro-bioreactors and organ-on-chips platforms.Microfluidic techniques have been extensively used for efficient manipulation of fluid flow in microscale for biomedical research and analytical chemistry. The control of flow in microfluidic networks is crucial for cell sorting, cell collection, flow mixing, cell adhesion and culture, droplet manipulation and flow driving 1 . Moreover, the flow rate needs to be accurately quantified to determine the concentration of cells 2 , and production of hollow microspheres . A slight change in flow rate may lead to a size variation in the products. To precisely handle fluids at the microscale, the real-time detection of flow rate in microfluidic environment is essential and urgently needed though challenging.Organ-on-a-chip (OOC) technology, in particular, aims to build biomimetic in vitro physiological micro-organs to compliment animal models in biological systems and benefit the pharmaceutical industry for drug discovery 7,8 . Many groups including ours have developed OOC platforms made of microbioreactors and integrated sensors for long-term and real-time monitoring the microenvironment, screening the status of miniaturized organs, and characterizing the response of micro-tissues to drugs [9][10][11][12][13] . The real-time measurement of heat transfer 14 , differential pressure 15 , pH and oxygen 11 and biomarkers 10 are central to biomimetic performance of OOC systems. Miniaturized biosensors provide favorable features like low-cost reagents consumption, decreased processing time, reduced sample volume, laminar flow to cells, parallel detection for multiple samples as well as portability 12,13,16 . However, the OOC systems still need on-chip integrated flow sensors compatible with their fabrication processes and functions 17. The OOC platforms require the...
Infection diagnosis and antibiotic susceptibility testing (AST) are time-consuming and often laborious clinical practices. This paper presents a microwave-microfluidic biosensor for rapid, contactless and non-invasive device for testing the concentration and growth of Escherichia Coli (E. Coli) in medium solutions of different pH to increase the efficacy of clinical microbiology practices. The thin layer interface between the microfluidic channel and the microwave resonator significantly enhanced the detection sensitivity. The microfluidic chip, fabricated using standard soft lithography, was injected with bacterial samples and incorporated with a microwave microstrip ring resonator sensor with an operation frequency of 2.5 GHz and initial quality factor of 83 for detecting the concentration and growth of bacteria. The resonator had a coupling gap area on of 1.5 × 1.5 mm2 as of its sensitive region. The presence of different concentrations of bacteria in different pH solutions were detected via screening the changes in resonant amplitude and frequency responses of the microwave system. The sensor device demonstrated near immediate response to changes in the concentration of bacteria and maximum sensitivity of 3.4 MHz compared to a logarithm value of bacteria concentration. The minimum prepared optical transparency of bacteria was tested at an OD600 value of 0.003. The sensor’s resonant frequency and amplitude parameters were utilized to monitor bacteria growth during a 500-minute time frame, which demonstrated a stable response with respect to detecting the bacterial proliferation. A highly linear response was demonstrated for detecting bacteria concentration at various pH values. The growth of bacteria analyzed over the resonator showed an exponential growth curve with respect to time and concurred with the lag-log-stationary-death model of cell growth. This biosensor is one step forward to automate the complex AST workflow of clinical microbiology laboratories for rapid and automated detection of bacteria as well as screening the bacteria proliferation in response to antibiotics.
Steady-state (SRMC) and time-resolved microwave photoconductivity (TRMC) are key techniques used to perform the contact-less determination of carrier density, transport, trapping, and recombination parameters in charge transport materials such as organic semiconductors and dyes, inorganic semiconductors, and metal−insulator composites, which find use in conductive inks, thin film transistors, lightemitting diodes, photocatalysts, and photovoltaics. We present the theory, design, simulation, and fabrication of a planar microwave ring resonator operating at 5.25 GHz with a quality factor of 224, to perform SRMC and TRMC measurements. Our method consists of measuring the resonance frequency (f 0 ) and Q-factor of the microwave resonator with the sample to be probed placed in a defined sensitive region of the resonator where the microwave field is highly concentrated. We also provide proof of concept measurements of the time-resolved microwave photoresponse of anatase-phase TiO 2 nanotube array membranes (TNTAMs) using the planar microstrip resonator. An unusual observation was the persistence of charged pair states in TNTAMs for several hours at room temperature under ambient conditions. Fast (120−220 s), slow (1300−2850 s), and very slow (6−26 h) components were extracted from the long-lived photoconductive decays of TNTAMs in response to 365, 250, and 405 nm illumination and assigned to various trap-mediated processes in TiO 2 nanotubes.
Sensing of molecular analytes by probing the effects of their interaction with microwaves is emerging as a cheap, compact, label-free and highly sensitive detection and quantification technique. Microstrip ring-type resonators are particularly favored for this purpose due to their planar sensing geometry, electromagnetic field enhancements in the coupling gap and compatibility with established printed circuit board manufacturing. However, the lack of selectivity in what is essentially a permittivity-sensing method is an impediment to wider adoption and implementation of this sensing platform. By placing a polycrystalline anatase-phase TiO2 nanotube membrane in the coupling gap of a microwave resonator, we engineer selectivity for the detection and differentiation of methanol, ethanol and 2-propanol. The scavenging of reactive trapped holes by aliphatic alcohols adsorbed on TiO2 is responsible for the alcohol-specific detection while the different short chain alcohols are distinguished on the basis of differences in their microwave response. Electrodeless microwave sensors which allow spectral and time-dependent monitoring of the resonance frequency and quality factor provide a wealth of information in comparison with electrode-based resistive sensors for the detection of volatile organic compounds. A high dynamic range (400 ppm-10,000 ppm) is demonstrated for methanol detection.
A microbead-assisted planar microwave resonator for organic vapor sensing applications is presented. The core of this sensor is a planar microstrip split-ring resonator, integrated with an active feedback loop to enhance the initial quality factor from 200 to $1 M at an operational resonance frequency of 1.42 GHz. Two different types of microbeads, beaded activated carbon (BAC) and polymer based (V503) beads, are investigated in non-contact mode for use as gas adsorbents in the gas sensing device. 2-Butoxyethanol (BE) is used in various concentrations as the target gas, and the transmitted power (S21) of the two port resonator is measured. The two main microwave parameters of resonance frequency and quality factor are extracted from S21 since these parameters are less susceptible to environmental and instrumental noise than the amplitude. Measured results demonstrate a minimum resonance frequency shift of 10 kHz for a 35 ppm concentration of BE exposure to carbon beads and 160 kHz for the polymer based adsorbent at the same concentration. The quality factor of the resonator also changed for different concentrations, but a distinguishable variation is observed for the BAC adsorbents. The high quality factor of the sensor provides the opportunity of real time monitoring of the adsorbent behaviors in remote sensing mode with very high resolution. V C 2015 AIP Publishing LLC. [http://dx.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.