We report here the chemical modification of poly(methyl methacrylate) (PMMA) surfaces by their reaction with the monoanion of alpha,omega-diaminoalkanes (aminolysis reaction) to yield amine-terminated PMMA surfaces. It is found that the amine functionalities are tethered to the PMMA backbone through an alkane bridge to amide bonds formed during the aminolysis of the surface ester functionalities. The distribution of the amine termini is quite uniform as judged by fluorescence micrographs. It is found that the electroosmotic flow in aminated PMMA microchannels is reversed when compared to that in unmodified channels. In addition, it is demonstrated that enzymes can be immobilized onto the amine-terminated PMMA surfaces and are effective in the restriction digestion of dsDNAs. Finally, the availability of the surface amine groups is further demonstrated by their reaction with n-octadecane-1-isocyanate to form PMMA surfaces terminated with well-ordered and highly crystalline octadecane chains.
An on-column contact conductivity detector was developed for the analysis of various mono- and polyanionic compounds separated by electrophoresis chips fabricated in poly(methyl methacrylate) (PMMA) using hot embossing techniques from Ni electroforms. The detector consisted of a pair of Pt wires (127 microm diameter) with an end-to-end spacing of approximately 20 microm and situated within the fluidic channel. The waveform applied to the electrode pair was a bipolar pulse with a frequency of 5.0 kHz and was used to reduce the charging current from measurement so that the current recorded at the end of one pulse is more representative of the solution conductivity. Using the detector, separations of amino acids, peptides, proteins, and oligonucleotides were demonstrated. For the amino acids and peptides, free-solution zone electrophoresis was performed. A calibration plot for the amino acid alanine was found to be linear from approximately 10 to 100 nM in a carrier electrolyte consisting of 10 mM triethylamonium acetate. The concentration detection limit was found to be 8.0 nM, with the corresponding mass detection limit equal to 3.4 amol (injection volume = 425 pL). The protein separations with conductivity detection were performed using MEKC, in which the carrier electrolyte contained the anionic surfactant sodium dodecyl sulfate (SDS) above its cmc. Near baseline resolution was achieved in the PMMA microchip for a solution containing 8 different proteins. In the case of the DNA fragments, capillary electrochromatography was used with a C18-modified PMMA chip and a carrier electrolyte containing an ion-pairing agent.
A 16-channel microfluidic chip with an integrated contact conductivity sensor array is presented. The microfluidic network consisted of 16 separation channels that were hot-embossed into polycarbonate (PC) using a high-precision micromilled metal master. All channels were 40 microm deep and 60 microm wide with an effective separation length of 40 mm. A gold (Au) sensor array was lithographically patterned onto a PC cover plate and assembled to the fluidic chip via thermal bonding in such a way that a pair of Au microelectrodes (60 microm wide with a 5 microm spacing) was incorporated into each of the 16 channels and served as independent contact conductivity detectors. The spacing between the corresponding fluidic reservoirs for each separation channel was set to 9 mm, which allowed for loading samples and buffers to all 40 reservoirs situated on the microchip in only five pipetting steps using an 8-channel pipettor. A printed circuit board (PCB) with platinum (Pt) wires was used to distribute the electrophoresis high-voltage to all reservoirs situated on the fluidic chip. Another PCB was used for collecting the conductivity signals from the patterned Au microelectrodes. The device performance was evaluated using microchip capillary zone electrophoresis (mu-CZE) of amino acid, peptide, and protein mixtures as well as oligonucleotides that were separated via microchip capillary electrochromatography (mu-CEC). The separations were performed with an electric field (E) of 90 V/cm and were completed in less than 4 min in all cases. The conductivity detection was carried out using a bipolar pulse voltage waveform with a pulse amplitude of +/-0.6 V and a frequency of 6.0 kHz. The conductivity sensor array concentration limit of detection (SNR = 3) was determined to be 7.1 microM for alanine. The separation efficiency was found to be 6.4 x 10(4), 2.0 x 10(3), 4.8 x 10(3), and 3.4 x 10(2) plates for the mu-CEC of the oligonucleotides and mu-CZE of the amino acids, peptides, and proteins, respectively, with an average channel-to-channel migration time reproducibility of 2.8%. The average resolution obtained for mu-CEC of the oligonucleotides and mu-CZE of the amino acids, peptides, and proteins was 4.6, 1.0, 0.9, and 1.0, respectively. To the best of our knowledge, this report is the first to describe a multichannel microchip electrophoresis device with integrated contact conductivity sensor array.
We describe the development of an integrated microelectrophoretic system consisting of a contact conductivity detector mounted on-chip for monitoring the separation of double-stranded (ds) DNA fragments produced via the polymerase chain reaction (PCR) using microcapillary electrochromatography as the separation mode. The separation was carried out in a polymer-based microfluidic device, hot-embossed into poly(methylmethacrylate) (PMMA), whose walls were functionalized to produce a C(18)-terminated surface to act as the stationary phase (open channel format). The carrier electrolyte contained the ion-pairing agent, triethylammonium acetate (TEAA) to allow the separation to be carried out using reverse-phase ion-pair capillary electrochromatography (RP-IPCEC). The microelectrophoretic separations were investigated utilizing various solvent strengths (acetonitrile/water) with 25 mM TEAA to observe the effects on the separation efficiency as well as the chromatographic development time and detector performance. The field strength significantly affected the quality of the separation, with no separation observed at 333 V/cm for a low mass dsDNA sizing ladder, but baseline separation achieved using a field strength of 67 V/cm. It was observed that the solvent strength affected the retention behavior of the polyanionic molecules as well as the electroosmotic mobility. Higher acetonitrile compositions in the run buffer resulted in reduced plate numbers, which produced lower chromatographic resolution. The use of conductivity detection allowed mass detection sensitivities in the range of 10(-21) mol with a separation efficiency of 10(4) plates and the performance of the detector independent of the acetonitrile content used in the carrier electrolyte.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.