In a retrospective study validated by a standardized clinical and radiological examination, the bone regeneration in 90 patients with cystic mandibular defects was examined. In 50 patients bony defect reconstructions with human demineralised bone matrix (HDBM) were carried out, while in a comparable group of 40 patients the hollow pockets were left to regenerate bone spontaneously. The bone regeneration after the implantation of human demineralised bone matrix (HDBM) was subjected to a comparative validation. Osteoinductive proteins present in HDBM (bone morphogenetic proteins) can diffuse into the implant seat and induce new bone formation (osteoinduction). A markedly faster and more thorough bone regeneration was demonstrated after the surgical therapy of cystic mandibular lesions with HDBM than without. HDBM also proved to be exceptionally biocompatible.
The purpose of this study was to determine the optimal scanning technique for lesion detection in a small bowel phantom and to evaluate the virtual endoscopy (VE) technique in patients. A small bowel phantom with a fold thickness of 7 mm and length of 115 cm was prepared with nine round lesions (3 x 1 mm, 2 x 2 mm, 2 x 3 mm, 2 x 4 mm). Spiral CT parameters were 7/7/4, 3/5/2, 3/5/1, 1.5/3/1 (slice thickness/table feed/reconstruction interval). VE was done using volume rendering technique with 1 cm distance between images and 120 degrees viewing angle. Two masked readers were asked to determine the number and location of the lesions. Seven patients underwent an abdominal CT during one breathhold after placement of a duodenal tube and filling of the small bowel with methyl cellulose contrast solution. VE images were compared with the axial slices with respect to detectability of pathology. With the 7/7/4 protocol only the 4-mm lesions were visualised with fuzzy contours. The 3/5/2 protocol showed both 4-mm lesions, one 3-mm lesion and one false positive lesion. The 3/5/1 protocol showed both 4-mm and both 3-mm (one uncertain) lesions with improved sharpness, and no false positive lesions. One 2-mm and one 1-mm lesion were additionally seen with the 1.5/3/1 protocol. Path definition was difficult in sharp turns or kinks in the lumen. In all patients, no difference was found between VE and axial slices for bowel pathology; however, axial slices showed 'outside' information that was not included in VE. We conclude that the 3/5/2 protocol may be regarded as an optimal compromise between lesion detection, coverage during one breathhold, and number of reconstructed images in patients; round lesions of 4 mm in diameter can be detected with high certainty.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.