Background-Treatment of in-stent restenosis with paclitaxel-coated balloon catheter as compared with plain balloon angioplasty has shown surprisingly low late lumen loss at 6 months and fewer major adverse cardiac events up to 2 years. We compared the efficacy and safety of a paclitaxel-coated balloon with a paclitaxel-eluting stent as the current standard of care. Methods and Results-One hundred thirty-one patients with coronary in-stent restenosis were randomly assigned to treatment by a paclitaxel-coated balloon (3 g/mm 2 ) or a paclitaxel-eluting stent. The main inclusion criteria encompassed diameter stenosis of Ն70% and Յ22 mm in length, with a vessel diameter of 2.5 to 3.5 mm. The primary end point was angiographic in-segment late lumen loss. Quantitative coronary angiography revealed no differences in baseline parameters. At 6 months follow-up, in-segment late lumen loss was 0.38Ϯ0.61 mm in the drug-eluting stent group versus 0.17Ϯ0.42 mm (Pϭ0.03) in the drug-coated balloon group, resulting in a binary restenosis rate of 12 of 59 (20%) versus 4 of 57 (7%; Pϭ0.06). At 12 months, the rate of major adverse cardiac events were 22% and 9%, respectively (Pϭ0.08). This difference was primarily due to the need for target lesion revascularization in 4 patients (6%) in the coated-balloon group, compared with 10 patients (15%) in the stent group (Pϭ0.15).
Conclusions-Treatment
Treatment of coronary stenosis in small coronary vessels with the paclitaxel-coated balloon was well tolerated. It may offer an alternative to the implantation of a drug-eluting stent (ClinicalTrials.gov Identifier: NCT00404144).
Percutaneous treatment of bifurcation lesions with a drug-eluting balloon resulted in a procedural success of 100%. Follow-up angiography at nine months showed DES-like results in MB and SB. However, when the DEB was used in combination with a BMS (MB), the possibility of late stent thrombosis cannot be ruled out.
Treatment of small vessel coronary artery disease with a paclitaxel-iopromide-coated balloon exhibited good six-month angiographic and one-year clinical data that persisted during the three-year follow-up period. Randomised trials will clarify its role as an alternative to drug-eluting stents in the treatment of small vessel coronary artery disease. (ClinicalTrials.gov Identifier: NCT00404144).
The six-month superiority of the paclitaxel-coated balloon compared to the paclitaxel-eluting stent in the treatment of bare metal coronary in-stent restenosis persisted throughout the three-year clinical follow-up period indicating stability of the lesions treated. (ClinicalTrials.gov Identifier: NCT00393315).
ObjectiveThe objective of this study was to assess the safety and efficacy of a polymer-free sirolimus coated, ultrathin strut drug-eluting stent (PF-SES) in an unselected patient population with a focus on acute coronary syndrome (ACS). Furthermore, stable coronary artery disease (CAD) with short (≤6 months) versus long (>6 months) dual antiplatelet therapy (DAPT) were also studied.MethodsPatients who received PF-SES were investigated in an unselected large-scale international, single-armed, multicenter, ‘all comers’ observational study. The primary endpoint was the 9-month target lesion revascularisation (TLR) rate, whereas secondary endpoints included the 9-month major adverse cardiac events (MACE) and procedural success rates. A priori defined subgroups such as patients with ACS, diabetes, lesion subsets and procedural characteristics relative to DAPT were investigated.ResultsA total of 2877 patients of whom 1084 had ACS were treated with PF-SES (1.31±0.75 stents per patient). At 9 months, the accumulated overall TLR rate was 2.3% (58/2513). There was no significant difference between ACS and stable CAD (2.6% vs 2.1%, p=0.389). However, the overall MACE rate was 4.3% (108/2513) with a higher rate in patients with ACS when compared with the stable CAD subgroup (6.1%, 58/947 vs 3.2%, 50/1566, p<0.001).ConclusionsPF-SES angioplasty is safe and effective in the daily clinical routine with low rates of TLR and MACE in an unselected patient population. Our data are in agreement with prior clinical findings that extended DAPT duration beyond 6 months do not improve clinical outcomes in patients with stable CAD (ClinicalTrials.gov Identifier NCT02629575).Trial registration numberNCT02629575.
The clinical and angiographic outcome of the combination of the drug-eluting balloon SeQuent Please with a cobalt chromium stent compared to the drug eluting Taxus stent are similar.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.