Fixation of the removed femoral segment with a cable provided adequate rotational stability and decreased the operating time, leading to early union at the osteotomy site.
This study aimed to determine the fate of the lateral femoral cutaneous nerve (LFCN) after anterior reduction of the hip with or without pelvic or proximal femoral osteotomy for acetabular dysplasia. Using the antidromic technique, recording the response using standard electromyography equipment, evaluation was made of the LFCN in 36 hips of 24 patients (18 female and six male). The response was absent in six patients (25%) and nine patients (37.5%) had a somatosensory evoked potential latency greater than 40 ms. There was no relationship between somatosensory evoked potential latency or absent response with the type of incision or procedure (P=0.229 and 0.794, respectively). LFCN injury after anterior open reduction of the hip has an unexpectedly high incidence in the young paediatric age group. Exposure of the nerve during surgery can negatively affect the nerve nutrition leading to neuropraxia.
Background:Crowe type IV developmental dysplasia of hip (DDH), subtrochanteric shortening osteotomy is required to restore the hip joint. Several approaches have been described for subtrochanteric shortening osteotomy. Several osteotomy fixation techniques have been defined for Crowe type IV DDH. This study evaluates the outcomes of subtrochanteric shortening osteotomy fixed with a combination of split onlay autograft and distal fluted femoral stem.Materials and Methods:A retrospective study was carried out on 41 hips of 37 patients treated with total hip replacement for Crowe type IV developmental dysplasia of the hip by subtrochanteric transverse osteotomy and fixed with split intercalary autograft by two cables. A femoral stem with proximal coated and distally fluted was used. The patients were evaluated at a mean of 34 months (range 12–68 months) for union time, leg equalization, and clinical outcomes. Results:Mean time of union was 13.5 ± 4.6 weeks (range 6–24 weeks). Intraoperative instability of the osteotomy site (n = 16) that was encountered at the trial stage was restored properly by this surgical protocol. Leg length discrepancies were improved to 1.4 ± 0.8 cm (range 0–3 cm). Harris scores were improved from 47.7 ± 10.8 (range 30–68) to 88 ± 5.6 (range 72–98) (P < 0.05) points. There was no nonunion.Conclusions:Distally well-fitted stem and strengthening of fixation with split intercalary autograft promote additional rotational stability and improve bone union.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.