Primary biological aerosol particles (PBAP) encompass many particle types that are derived from several biological kingdoms. These aerosol particles can be composed of both whole living units such as pollen, bacteria, and fungi, as well as from mechanically formed particles, such as plant debris. They constitute a significant proportion of the overall atmospheric particle load and have been linked with adverse health issues and climatic effects on the environment. Traditional methods for their analysis have focused on the direct capture of PBAP before subsequent laboratory analysis. These analysis types have generally relied on direct optical microscopy or incubation on agar plates, followed by time-consuming microbiological investigation. In an effort to address some of these deficits, real-time fluorescence monitors have come to prominence in the analysis of PBAP. These instruments offer significant advantages over traditional methods, including the measurement of concentrations, as well as the potential to simultaneously identify individual analyte particles in real-time. Due to the automated nature of these measurements, large data sets can be collected and analyzed with relative ease. This review seeks to highlight and discuss the extensive literature pertaining to the most commonly used commercially available real-time fluorescence monitors (WIBS, UV-APS and BioScout). It discusses the instruments operating principles, their limitations and advantages, and the various environments in which they have been deployed. The review provides a detailed examination of the ambient fluorescent aerosol particle concentration profiles that are obtained by these studies, along with the various strategies adopted by researchers to analyze the substantial data sets the instruments generate. Finally, a brief reflection is presented on the role that future instrumentation may provide in revolutionizing this area of atmospheric research.
Throughout the COVID-19 pandemic, meat processing plants have been vulnerable to outbreaks of SARS-CoV-2 infection. Transmission of the virus is difficult to control in these settings because of a combination of factors including environmental conditions and the specific nature of the work. This paper describes a retrospective outbreak investigation in a meat processing plant, a description of the measures taken to prevent or contain further outbreaks, and insights on how those with specific knowledge of the working environment of these plants can collaborate with public health authorities to ensure optimal outbreak control. The plant experienced 111 confirmed positive asymptomatic cases in total with an estimated attack rate of 38% during a five-week period. 4 weeks after the first case, mass screening of all workers was conducted by the public health authorities. Thirty-two workers tested positive, of which 16 (50%) worked in one particular area of the plant, the boning hall (n = 60). The research team prepared and carried out semi-structured interviews with the plant personnel who were charged with COVID control within the plant. They carried out assessments of operational risk factors and also undertook air quality monitoring in the boning hall and abattoir. The air quality measurements in the boning hall showed a gradual build-up of carbon dioxide and aerosol particles over the course of a work shift, confirming that this poorly ventilated area of the plant had an environment that was highly favorable for aerosol transmission of SARS-CoV-2. Assessment of operational conditions incorporated visual surveys of the plant during the working day. Prior to and during the first 2 weeks of the outbreak, multiple measures were introduced into the plant by management, including physical distancing, provision of educational material to workers, visitor restrictions, and environmental monitoring. After the implementation of these measures and their progressive refinement by plant management, the factory had no further linked cases (clusters) or outbreaks for the following 198 days. The tailored approach to risk mitigation adopted in this meat processing plant shows that generic risk mitigation measures, as recommended by public health authorities, can be successfully adapted and optimized by designated plant emergency response teams.
Flushing toilets generate visible droplets from turbulent flow, but also produce numerous smaller airborne droplets (∼micrometres in size) through atomisation. Flushing may aerosolise pathogens from stool or urine, spreading disease. This study continuously monitored aerosols in a shared office lavatory over a week using a biological particle detector, the Wideband Integrated Bioaerosol Sensor (WIBS). This instrument monitors individual particle sizes and numbers and identifies fluorescent particles likely to be droplets containing bacteria. The toilet was a standard wash-down design, (Armitage Shanks), with a lid. No statistically significant variation between fluorescent particle counts was found between periods prior to flushing. Fluorescent particle numbers and intensity increased with toilet flushing, remaining above background for 5 minutes post-flushing on average. Placing the toilet lid down significantly (P<0.001) reduced total and fluorescent particle counts during and after flushing by 30-50%. Lid usage significantly increased (P<0.001) particle diameter from 1.5 μm to 2.1 μm and increased particle fluorescence intensity (P<0.001) during flushing and after flushing, intensity remaining above background for 16 minutes. This suggests standard lid usage reduces but does not eliminate flush-related bioaerosols. Lid-use changes their characteristics and apparently prolongs their residence time in room air. The aerosol change could represent particle agglomeration by a pressure-related Kelvin effect or particle re-aerosolisation from different surfaces in the toilet rather than exclusively originating from droplet generation. Previous studies reporting the effect of toilet lids have found that they prevent the spread of visible droplets on flushing, however the effect on smaller particles is less clear cut.
Background: Several medical procedures involving the respiratory tract are considered as 'aerosol-generating procedures'. Aerosols from these procedures may be inhaled by bystanders, and there are consequent concerns regarding the transmission of infection or, specific to nebulized therapy, secondary drug exposure. Aim: To assess the efficacy of a proprietary high-efficiency-particulate-air-filtering extractor tent on reducing the aerosol dispersal of nebulized bronchodilator drugs. Methods: The study was conducted in an unoccupied outpatient room at St. James's Hospital, Dublin, Ireland. A novel real-time, fluorescent particle counter, the Wideband Integrated Bioaerosol Sensor (WIBS), monitored room air continuously for 3 h. Baseline airborne particle count and count during nebulization of bronchodilator drug solutions were recorded. Findings: Nebulization within the tent prevented any increase over background level. Nebulization directly into room air resulted in mean fluorescent particle counts of 4.75 x 10 5 /m 3 and 4.21 x 10 5 /m 3 for Ventolin and Ipramol, respectively, representing more than 400-fold increases over mean background level. More than 99.3% of drug particles were <2
Throughout the COVID-19 pandemic, meat processing plants have been vulnerable to outbreaks of SARS-CoV-2 infection. Transmission of the virus is difficult to control in these settings because of a combination of factors including environmental conditions and the specific nature of the work. This paper describes a retrospective outbreak investigation in a meat processing plant, a description of the measures taken to prevent or contain further outbreaks, and insights on how those with specific knowledge of the working environment of these plants can collaborate with public health authorities to ensure optimal outbreak control. The plant experienced 111 confirmed positive asymptomatic cases in total with an estimated attack rate of 38% during a five-week period. Four weeks after the first case, mass screening of all workers was conducted by the public health authorities. Thirty-two workers tested positive, of which 16 (50%) worked in one particular area of the plant, the boning hall (n=60). The research team prepared and carried out semi-structured interviews with the plant personnel who were charged with COVID control within the plant. They carried out assessments of operational risk factors and also undertook air quality monitoring in the boning hall and abattoir. The air quality measurements in the boning hall showed a gradual build-up of carbon dioxide and aerosol particles over the course of a work shift, confirming that this poorly ventilated area of the plant had an environment that was highly favourable for aerosol transmission of SARS-CoV-2. Assessment of operational conditions incorporated visual surveys of the plant during the working day. Prior to and during the first two weeks of the outbreak, multiple measures were introduced into the plant by management, including physical distancing, provision of educational material to workers, visitor restrictions, and environmental monitoring. After the implementation of these measures and their progressive refinement by plant management, the factory has not had any further linked cases (clusters) or outbreaks to date. The tailored approach to risk mitigation adopted in this meat processing plant shows that generic risk mitigation measures, as recommended by public health authorities, can be successfully adapted and optimized by designated plant emergency response teams.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.