Surgery for cataracts with delayed presentation helps to regain functional vision, which can be used for navigation and low vision aids.
Purpose: To assess the use of smartphone-based direct ophthalmoscope photography for screening of diabetic retinopathy (DR) in known diabetic patients walking into a general practitioner's clinic and referring them to a vitreoretinal specialist for further evaluation and management if required. Methodos: The study included 94 eyes of 47 walk-in patients in a general practitioner's OPD who were known to have type 2 diabetes mellitus and were already on treatment for the same. Results: The study included 47 patients with diabetes with a mean age of 56.2 ± 9.4 years. The Cohen's kappa values revealed that the diagnosis related to the DR status made using a camera was in substantial agreement with the clinical diagnosis (Kappa value: 0.770). The Cohen's kappa values revealed that the diagnosis related to the DME made using a camera was in moderate agreement with the clinical diagnosis (Kappa value: 0.410). The agreement between the findings of the camera and clinical diagnosis was statistically significant ( P < 0.05). Conclusion: Direct ophthalmoscope-based smartphone imaging can be a useful tool in the OPD of a general practitioner. These images can be assessed for retinopathy, and patients can be referred to a vitreoretinal specialist for further evaluation and management if needed. Hence, the burden of vision loss due to complications of DR in the rural sector can be abridged.
Purpose: To compare readings of intraocular pressure (IOP) taken with the Goldmann applanation tonometer (GAT), the non-contact tonometer (NCT), and the rebound tonometer (RBT), and to compare their correlation with central corneal thickness (CCT). Methods: This was a prospective, cross-sectional, observational study to which patients above 18 years of age were enrolled. A total of 400 eyes of 200 non-glaucomatous patients underwent IOP recordings using the GAT, NCT, and RBT, and CCT was also noted. Informed consent of the patients was taken. The IOP readings taken via the three methods were compared and correlated with CCT. Paired t test was used to compare the two devices. Simple and multivariate linear regression analyses were used to study the relationship between factors. A P value less than 0.05 was considered significant. Correlation was determined using the Pearson correlation coefficient, and a Bland–Altman graph was plotted. Results: Mean IOP measured by the NCT was 15.65 ± 2.80 mmHg, by the RBT was 14.23 ± 3.05 mmHg, and by the GAT was 14.69 ± 2.97 mmHg. The mean CCT was 510.61 ± 33.83 microns. The difference between mean IOP recorded by the NCT and that by the RBT was 1.41 ± 2.39 mmHg, between the NCT and GAT was 0.95 ± 2.03 mmHg, and between the GAT and RBT was 0.45 ± 2.22 mmHg. The difference between the IO P values was statistically significant ( P < 0.005). All tonometers showed a statistically significant correlation with CCT, but it was observed that the NCT had a stronger correlation (0.4037). Conclusion: The IOP readings taken by all the three methods were comparable; however, RBT values were closer to GAT values. CCT did influence the IOP values, and this should be kept in mind while evaluating.
Purpose: The aim of this study was to examine the role of preoperative Nd:YAG laser anterior capsulotomy in preventing intraoperative complications in mature intumescent cataracts. Design: A prospective, interventional, observational study. Methods: A total of 52 eyes of 52 patients were selected in this prospective study. Preoperative Nd:YAG laser anterior capsulotomy was performed in all eyes with 1 shot of 1.2 mJ and a gush of the liquified cortex was noted. Anterior chamber depth was measured using anterior segment optical coherence tomography and intraocular pressure using Goldmann applanation tonometer were measured pre- and post-laser. Intraoperative complications and surgeon's operative comfort were noted. Results: There was a mean increase in anterior chamber depth by 0.24 mm and a mean decrease in intraocular pressure by 1.61 mm Hg postlaser. No intraoperative complications were noted except for capsulorhexis extension in 1 eye (1.92%). The surgeon experienced a good control while performing the capsulorhexis and overall an uneventful surgery. Conclusions: Preoperative Nd:YAG laser anterior capsulotomy is a safe and effective technique in reducing intralenticular pressure and avoiding intraoperative complications in mature intumescent cataracts.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.