Background: Cardiac manifestation of COVID-19 has been reported during the COVID pandemic. The role of cardiac arrhythmias in COVID-19 is insufficiently understood. This study assesses the incidence of cardiac arrhythmias and their prognostic implications in hospitalized COVID-19-patients. Methods: A total of 166 patients from eight centers who were hospitalized for COVID-19 from 03/2020–06/2020 were included. Medical records were systematically analyzed for baseline characteristics, biomarkers, cardiac arrhythmias and clinical outcome parameters related to the index hospitalization. Predisposing risk factors for arrhythmias were identified. Furthermore, the influence of arrhythmia on the course of disease and related outcomes was assessed using univariate and multiple regression analyses. Results: Arrhythmias were detected in 20.5% of patients. Atrial fibrillation was the most common arrhythmia. Age and cardiovascular disease were predictors for new-onset arrhythmia. Arrhythmia was associated with a pronounced increase in cardiac biomarkers, prolonged hospitalization, and admission to intensive- or intermediate-care-units, mechanical ventilation and in-hospital mortality. In multiple regression analyses, incident arrhythmia was strongly associated with duration of hospitalization and mechanical ventilation. Cardiovascular disease was associated with increased mortality. Conclusions: Arrhythmia was the most common cardiac event in association with hospitalization for COVID-19. Older age and cardiovascular disease predisposed for arrhythmia during hospitalization. Whereas in-hospital mortality is affected by underlying cardiovascular conditions, arrhythmia during hospitalization for COVID-19 is independently associated with prolonged hospitalization and mechanical ventilation. Thus, incident arrhythmia may indicate a patient subgroup at risk for a severe course of disease.
The dentate gyrus is the main hippocampal input structure receiving strong excitatory cortical afferents via the perforant path. Therefore, inhibition at this 'hippocampal gate' is important, particularly during postnatal development, when the hippocampal network is prone to seizures. The present study describes the development of tonic GABAergic inhibition in mouse dentate gyrus. A prominent tonic GABAergic component was already present at early postnatal stages (postnatal day 3), in contrast to the slowly developing phasic postsynaptic GABAergic currents. Tonic currents were mediated by GABA(A) receptors containing α(5)- and δ-subunits, which are sensitive to low ambient GABA concentrations. The extracellular GABA level was determined by synaptic GABA release and GABA uptake via the GABA transporter 1. The contribution of these main regulatory components was surprisingly stable during postnatal granule cell maturation. Throughout postnatal development, tonic GABAergic signals were inhibitory. They increased the action potential threshold of granule cells and reduced network excitability, starting as early as postnatal day 3. Thus, tonic inhibition is already functional at early developmental stages and plays a key role in regulating the excitation/inhibition balance of both the adult and the maturing dentate gyrus.
The wearable cardioverter-defibrillator (WCD) was introduced to provide protection from sudden cardiac death (SCD) in patients with transiently elevated risk or during ongoing risk stratification. Benefits and clinical characteristics of routine WCD use remain to be assessed in larger patient populations. This study aims to identify determinants of WCD compliance, therapies, and inappropriate alarms in a real-life cohort. A total of 106 cases (68.9% male) were included between 11/2010 and 04/2016. WCD therapies, automatically recorded arrhythmia episodes, inappropriate WCD alarms, patient compliance, and outcome after WCD prescription were analyzed. Median duration of WCD use was 58.5 days. Average daily wearing time was 22.7 h. Compliance was reduced in patients ≤ 50 years. Three patients received WCD therapies (2.8%). In one case ventricular fibrillation (VF) was appropriately terminated with the first shock. Two patients received inappropriate WCD therapies due to WCD algorithm activation during ventricular pacemaker stimulation. One patient died of asystole while carrying a WCD (0.9%). Additional arrhythmias detected comprised self-terminating sustained ventricular tachycardia (VT; 2.8%), non-sustained VT (2.8%), and supraventricular arrhythmias (5.7%). Inappropriate WCD alarms due to over-/undersensing occurred in 77/106 patients (72.6%), of which 41 (38.7%) experienced ≥ 10 inappropriate WCD alarms during the prescription period. Thirteen patients (12.3%) displayed a mean of > 1 inappropriate alarms/day. WCD use was associated with high compliance and provided protection from VT/VF-related SCD. The majority of patients experienced inappropriate WCD alarms. Alterations in QRS morphology during pacemaker stimulation require consideration in WCD programming to prevent inappropriate alarms.
The mammalian hippocampus expresses several types of network oscillations which entrain neurons into transiently stable assemblies. These groups of co-active neurons are believed to support the formation, consolidation and recall of context-dependent memories. Formation of new assemblies occurs during theta- and gamma-oscillations under conditions of high cholinergic activity. Memory consolidation is linked to sharp wave-ripple oscillations (SPW-R) during decreased cholinergic tone. We hypothesized that increased cholinergic tone supports plastic changes of assemblies while low cholinergic tone favors their stability. Coherent spatiotemporal network patterns were measured during SPW-R activity in mouse hippocampal slices. We compared neuronal activity within the oscillating assemblies before and after a transient phase of carbachol-induced gamma oscillations. Single units maintained their coupling to SPW-R throughout the experiment and could be re-identified after the transient phase of gamma oscillations. However, the frequency of SPW-R-related unit firing was enhanced after muscarinic stimulation. At the network level, these changes resulted in altered patterns of extracellularly recorded SPW-R waveforms. In contrast, recording of ongoing SPW-R activity without intermittent cholinergic stimulation revealed remarkably stable repetitive activation of assemblies. These results show that activation of cholinergic receptors induces plasticity at the level of oscillating hippocampal assemblies, in line with the different role of gamma- and SPW-R network activity for memory formation and –consolidation, respectively.
Background: Coexistence of atrial fibrillation (AF) and heart failure with preserved ejection fraction (HFpEF) is common, affecting morbidity and prognosis. This study evaluates outcome after cryoballoon ablation for AF in HFpEF compared with patients without heart failure. Methods: A total of 102 AF patients with left ventricular ejection fraction ≥50% undergoing cryoballoon ablation were prospectively enrolled. Baseline evaluation included echocardiography, stress echocardiography, 6-minute walk test, biomarkers, and quality of life assessment (Short-Form-36). Procedural parameters and clinical, functional and echocardiographic end points at follow-up ≥12 months after AF ablation were compared between patients with and without HFpEF. Results: Patients with HFpEF (n=24) were older (median, 74 years versus 65 years; P =0.001) more often female (83% versus 28%; P <0.001) and characterized by more pronounced AF-related symptoms (median European Heart Rhythm Association score 3 versus 2; P <0.001), higher left atrial pressures (median, 14 mm Hg versus 10 mm Hg; P =0.008), reduced left atrial-appendage velocity (median, 36 cm/s versus 59 cm/s; P <0.001), and reduced distance in the 6-minute walk test (median, 488 m versus 539 m; P <0.001). Patients with HFpEF more often experienced AF recurrence (57% versus 23%; P =0.003), repeat AF ablation (39% versus 14%; P =0.01) and AF-related rehospitalization (26% versus 7%; P =0.016). Heart failure symptoms and elevated cardiac biomarkers persisted, even in patients with HFpEF with successful rhythm control at follow-up. Echocardiographic follow-up showed progression of adverse left atrial remodeling and no relevant improvement in diastolic function in HFpEF. Quality of life improved in patients without HFpEF, whereas patients with HFpEF still exhibited a lower physical component summary score (median, 41.5 versus 53.4; P <0.004). Conclusions: Patients with HFpEF constitute a distinct subgroup with elevated risk for AF recurrence after cryoballon ablation. Functional hallmarks of HFpEF persist, irrespective of rhythm status at follow-up. Future research is needed to optimize treatment strategies in patients with HFpEF. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04317911.
Background: Hypertension (HTN) constitutes a risk factor for the development of atrial fibrillation (AF), as well as for thromboembolic and bleeding events. We analysed the outcome after catheter ablation of AF in HTN in a cohort from the prospective multicenter German Ablation Registry. Methods: Between 03/2008 and 01/2010, 626 patients undergoing AF-ablation were analysed. Patients diagnosed with HTN (n = 386) were compared with patients without HTN (n = 240) with respect to baseline, procedural and long-term outcome parameters. Results: Patients with HTN were older and more often presented with persistent forms of AF and cardiac comorbidities. Major and moderate in-hospital complications were low. At long-term follow-up, major cardiovascular events were rare in both groups. Rates of AF-recurrence, freedom from antiarrhythmic medication and repeat ablation were not statistically different between groups. Most patients reported improvement of symptoms and satisfaction with the treatment. However, patients with HTN more frequently complained of dyspnea of New York Heart Association (NYHA) class ≥ II and angina. They were more often rehospitalized, particularly when persistent AF had been diagnosed. Conclusion: Catheter ablation of AF is associated with low complication rates and favorable arrhythmia-related results in patients with HTN. Residual clinical symptoms may be due to cardiac comorbidities and require additional attention in this important subgroup of AF-patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.