Our LDI is applicable in clinical otological practice and serves as a valuable addition to the routine audiological investigations for preoperative evaluation of the mobility and integrity of the ossicular chain.
A method is described that allows, for the first time, intraoperative vibration modes assessment of the acoustically stimulated stapes by means of scanning laser Doppler interferometry (LDI). The study was designed to answer the following questions: 1) Is LDI practical for taking measurements during surgery? 2) Are the results comparable to the findings in temporal bone preparations? and 3) Do the vibration characteristics of the stapes change after the posterior incudal ligament is detached from the incus? Seven patients with profound bilateral hearing loss who were undergoing cochlear implantation were included in the study. The measurement system was easily applicable for intraoperative measurements and allowed contact-free analysis with very high accuracy. No major differences in the results from the live human subjects and temporal bone preparations were observed. The stapes movement was predominantly pistonlike at the lower frequencies and became complex at higher frequencies. Sacrificing the posterior incudal ligament had no statistically significant effect on stapes vibration.KEY WORDS -laser Doppler interferometry, middle ear mechanics, posterior incudal ligament.
time was double in the open system (7:52±1:47 vs 3:12±1:20 min). Poor image quality in the open system prevented assessment of interspinous and intertuberous diameters in one woman and all measurements in another, both pregnant, with abdominal circumferences >120 cm. The open system was much more acceptable in terms of claustrophobia and confinement (both p<0.01). Claustrophobia interrupted one closed examination. Thirty-three percent of pregnant women in both systems reported fear of fetal harm. Sixty percent of all women preferred the open system, 7% the closed system, and 33% had no preference. Limits of agreement of 3-5% from the mean for all diameters confirmed good pelvimetric reproducibility. Women's preference for open-system MR pelvimetry is feasible with abdominal circumferences ≤120 cm.
AbstractOur objective was to compare maternal pelvimetry and patient acceptability between open low-field (0.5-T) and closed 1.5-T MR systems. Thirty women referred for pelvimetry (pregnant: n=15) were scanned twice in the supine position, once in the vertical open system and once in the closed system. Each patient completed a comfort and acceptability questionnaire. Pelvimetric and questionnaire data were compared between systems. Total scan
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.