This article provides a summary statement of recommended implementations of arterial spin labeling (ASL) for clinical applications. It is a consensus of the ISMRM Perfusion Study Group and the European ‘ASL in Dementia’ consortium, both of whom met to reach this consensus in October 2012 in Amsterdam. Although ASL continues to undergo rapid technical development, we believe that current ASL methods are robust and ready to provide useful clinical information, and that a consensus statement on recommended implementations will help the clinical community to adopt a standardized approach. In this article we describe the major considerations and tradeoffs in implementing an ASL protocol, and provide specific recommendations for a standard approach. Our conclusions are that, as an optimal default implementation we recommend: pseudo-continuous labeling, background suppression, a segmented 3D readout without vascular crushing gradients, and calculation and presentation of both label/control difference images and cerebral blood flow in absolute units using a simplified model.
This review provides a summary statement of recommended implementations of arterial spin labeling (ASL) for clinical applications. It is a consensus of the ISMRM Perfusion Study Group and the European ASL in Dementia consortium, both of whom met to reach this consensus in October 2012 in Amsterdam. Although ASL continues to undergo rapid technical development, we believe that current ASL methods are robust and ready to provide useful clinical information, and that a consensus statement on recommended implementations will help the clinical community to adopt a standardized approach. In this review, we describe the major considerations and trade‐offs in implementing an ASL protocol and provide specific recommendations for a standard approach. Our conclusion is that as an optimal default implementation, we recommend pseudo‐continuous labeling, background suppression, a segmented three‐dimensional readout without vascular crushing gradients, and calculation and presentation of both label/control difference images and cerebral blood flow in absolute units using a simplified model. Magn Reson Med 73:102–116, 2015. © 2014 Wiley Periodicals, Inc.
Purpose To investigate whether the blood-brain barrier (BBB) leaks blood-circulating substances in patients with early forms of Alzheimer disease (AD), and if so, to examine the extent and pattern of leakage. Materials and Methods This study was approved by the local medical ethical committees of the Maastricht University Medical Center and Leiden University Medical Center, and written informed consent was obtained from all subjects. For this pilot study, 16 patients with early AD and 17 healthy age-matched control subjects underwent dynamic contrast material-enhanced magnetic resonance (MR) imaging sequence with dual time resolution for 25 minutes. The Patlak graphical approach was used to quantify the BBB leakage rate and local blood plasma volume. Subsequent histogram analysis was used to determine the volume fraction of the leaking brain tissue. Differences were assessed with linear regression analysis, adjusted for confounding variables. Results The BBB leakage rate was significantly higher in patients compared with that in control subjects in the total gray matter (P < .05) and cortex (P = .03). Patients had a significantly higher volume fraction of the leaking brain tissue in the gray matter (P = .004), normal-appearing white matter (P < .04), deep gray matter (P = .01), and cortex (P = .004). When all subjects were considered, scores on the Mini-Mental State Examination decreased significantly with increasing leakage in the deep gray matter (P = .007) and cortex (P < .05). Conclusion The results of this study showed global BBB leakage in patients with early AD that is associated with cognitive decline. A compromised BBB may be part of a cascade of pathologic events that eventually lead to cognitive decline and dementia. RSNA, 2016 Online supplemental material is available for this article.
Pseudocontinuous arterial spin labeling MRI is a new arterial spin labeling technique that has the potential of combining advantages of continuous arterial spin labeling and pulsed arterial spin labeling. However, unlike continuous arterial spin labeling, the labeling process of pseudocontinuous arterial spin labeling is not strictly an adiabatic inversion and the efficiency of labeling may be subject specific. Here, three experiments were performed to study the labeling efficiency in pseudocontinuous arterial spin labeling MRI. First, the optimal labeling position was determined empirically to be approximately 84 mm below the anterior commissure-posterior commissure line in order to achieve the highest sensitivity. Second, an experimental method was developed to utilize phase-contrast velocity MRI as a normalization factor and to estimate the labeling efficiency in vivo, which was founded to be 0.86 6 0.06 (n 5 10, mean 6 standard deviation). Third, we compared the labeling efficiency of pseudocontinuous arterial spin labeling MRI under normocapnic and hypercapnic (inhalation of 5% CO 2 ) conditions and showed that a higher flow velocity in the feeding arteries resulted in a reduction in the labeling efficiency. In summary, our results suggest that labeling efficiency is a critical parameter in pseudocontinuous arterial spin labeling MRI not only in terms of achieving highest sensitivity but also in quantification of absolute cerebral blood flow in milliliters per minute per 100 g. We propose that the labeling efficiency should be estimated using phase-contrast velocity MRI on a subject-specific basis. Magn Reson Med 63:765-771,
In the evaluation of cerebrovascular CO2 reactivity measurements, it is often assumed that the diameter of the large intracranial arteries insonated by transcranial Doppler remains unaffected by changes in arterial CO2 partial pressure. However, the strong cerebral vasodilatory capacity of CO2 challenges this assumption, suggesting that there should be some changes in diameter, even if very small. Data from previous studies on effects of CO2 on cerebral artery diameter [middle cerebral artery (MCA)] have been inconsistent. In this study, we examined 10 healthy subjects (5 women, 5 men, age 21-30 yr). High-resolution (0.2 mm in-plane) MRI scans at 7 Tesla were used for direct observation of the MCA diameter during hypocapnia, -1 kPa (-7.5 mmHg), normocapnia, 0 kPa (0 mmHg), and two levels of hypercapnia, +1 and +2 kPa (7.5 and 15 mmHg), with respect to baseline. The vessel lumen was manually delineated by two independent observers. The results showed that the MCA diameter increased by 6.8 ± 2.9% in response to 2 kPa end-tidal P(CO2) (PET(CO2)) above baseline. However, no significant changes in diameter were observed at the -1 kPa (-1.2 ± 2.4%), and +1 kPa (+1.4 ± 3.2%) levels relative to normocapnia. The nonlinear response of the MCA diameter to CO2 was fitted as a continuous calibration curve. Cerebral blood flow changes measured by transcranial Doppler could be corrected by this calibration curve using concomitant PET(CO2) measurements. In conclusion, the MCA diameter remains constant during small deviations of the PET(CO2) from normocapnia, but increases at higher PET(CO2) values.
The measurement of the arterial input function by use of gradient echo sequences was investigated by in vitro and in vivo experiments. First, calibration curves representing the influence of the concentration of Gd-DTPA on both the phase and the amplitude of the MR signal were measured in human blood by means of a slow-infusion experiment. The results showed a linear increase in the phase velocity and a quadratic increase in ⌬R* 2 as a function of the Gd-DTPA concentration. Next, the resultant calibration curves were incorporated in a partial volume correction algorithm for the arterial input function determination. The algorithm was tested in a phantom experiment and was found to substantially improve the accuracy of the concentration measurement. Finally, the reproducibility of the arterial input function measurement was estimated in 16 patients by considering the input function of the left and the right sides as replicate measurements. This in vivo study showed that the reproducibility of the arterial input function determination using gradient echo sequences is improved by employing a partial volume correction algorithm based on the calibration curve for the contrast agent used. Magn Reson
Cerebral small vessel disease (cSVD) comprises pathological processes of the small vessels in the brain that may manifest clinically as stroke, cognitive impairment, dementia, or gait disturbance. It is generally accepted that endothelial dysfunction, including blood-brain barrier (BBB) failure, is pivotal in the pathophysiology. Recent years have seen increasing use of imaging, primarily dynamic contrast-enhanced magnetic resonance imaging, to assess BBB leakage, but there is considerable variability in the approaches and findings reported in the literature. Although dynamic contrast-enhanced magnetic resonance imaging is well established, challenges emerge in cSVD because of the subtle nature of BBB impairment. The purpose of this work, authored by members of the HARNESS Initiative, is to provide an in-depth review and position statement on magnetic resonance imaging measurement of subtle BBB leakage in clinical research studies, with aspects requiring further research identified. We further aim to provide information and consensus recommendations for new investigators wishing to study BBB failure in cSVD and dementia.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.