OBJECTIVES
This study analysed the patterns of extraction ranges, characteristics, advantages and disadvantages of median sternotomy (MS) and subxiphoid (SX) approaches for extended thymectomy.
METHODS
This study included patients with anterior mediastinum tumour and myasthenia gravis who underwent extended thymectomy at our institution between 2015 and 2018. There were 5 MS and 6 SX extended thymectomy surgeries with the VINCENT software. On preoperative computed tomography, the thymus area and fat tissue surrounding the thymus, which were planned for extraction, were traced using VINCENT (Ver. 4.0). We then constructed three-dimensional images and calculated the volumes. Evaluation of the extended thymectomy approach based on the residual fat tissue was required to determine the area of extended thymectomy.
RESULTS
No significant differences in operation time (min) [SX: 197.3 ± 34.0, MS: 206.6 ± 91.4, drainage duration (days), SX: 2.2 ± 1.0, MS: 2.2 ± 0.4, hospital stay (days), SX: 11.8 ± 1.2, MS: 13.4 ± 2.1, residual rate (%), SX: 29.9 ± 17.5, MS: 58.7 ± 18.0 (P = 0.0519)] were observed between the 2 groups. Bleeding was significantly lower for SX than for MS. The residual rate was lower for SX than for MS.
CONCLUSIONS
Considering the amount of the residual fat tissue, the SX approach allows an adequate dissection area for extended thymectomy compared with the MS approach.
Background
Given the subtle pathological signs of adenocarcinoma in situ (AIS) and minimally invasive adenocarcinoma (MIA), effective differentiation between the two entities is crucial. However, it is difficult to predict these conditions using preoperative computed tomography (CT) imaging. In this study, we investigated whether histological diagnosis of AIS and MIA using quantitative three‐dimensional CT imaging analysis could be predicted.
Methods
We retrospectively analyzed the images and histopathological findings of patients with lung cancer who were diagnosed with AIS or MIA between January 2017 and June 2018. We used Synapse Vincent (v. 4.3) (Fujifilm) software to analyze the CT attenuation values and performed a histogram analysis.
Results
There were 22 patients with AIS and 22 with MIA. The ground‐glass nodule (GGN) rate was significantly higher in patients with AIS (p < 0.001), whereas the solid volume (p < 0.001) and solid rate (p = 0.001) were significantly higher in those with MIA. The mean (p = 0.002) and maximum (p = 0.025) CT values were significantly higher in patients with MIA. The 25th, 50th, 75th, and 97.5th percentiles (all p < 0.05) for the CT values were significantly higher in patients with MIA.
Conclusions
We demonstrated that quantitative analysis of 3D‐CT imaging data using software can help distinguish AIS from MIA. These analyses are useful for guiding decision‐making in the surgical management of early lung cancer, as well as subsequent follow‐up.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.