BackgroundThe eye's unique anatomy and its physiological and anatomical barriers can limit effective drug delivery into the eye.MethodsAn in vivo study was designed to determine the effectiveness and safety of ultrasound application in enhancing drug delivery in a rabbit model. Permeability of a steroid ophthalmic drug, dexamethasone sodium phosphate, was investigated in ultrasound- and sham-treated cases. For this study, an eye cup filled with dexamethasone sodium phosphate was placed on the cornea. Ultrasound was applied at intensity of 0.8 W/cm2 and frequency of 400 or 600 kHz for 5 min. The drug concentration in aqueous humor samples, collected 90 min after the treatment, was determined using chromatography methods. Light microscopy observations were done to determine the structural changes in the cornea as a result of ultrasound application.ResultsAn increase in drug concentration in aqueous humor samples of 2.8 times (p < 0.05) with ultrasound application at 400 kHz and 2.4 times (p < 0.01) with ultrasound application at 600 kHz was observed as compared to sham-treated samples. Histological analysis showed that the structural changes in the corneas exposed to ultrasound predominantly consisted of minor epithelial disorganization.ConclusionsUltrasound application enhanced the delivery of an anti-inflammatory ocular drug, dexamethasone sodium phosphate, through the cornea in vivo. Ultrasound-enhanced ocular drug delivery appears to be a promising area of research with a potential future application in a clinical setting.
Delivery of sufficient amounts of therapeutic drugs into the eye is often a challenging task. In this study, ultrasound application (frequencies of 400 KHz to 1 MHz, intensities of 0.3–1.0 W/cm2 and exposure duration of 5 min) was investigated to overcome the barrier properties of cornea, which is a typical route for topical administration of ophthalmic drugs. Permeability of ophthalmic drugs, tobramycin and dexamethasone and sodium fluorescein, a drug-mimicking compound, was studied in ultrasound- and sham-treated rabbit corneas in vitro using a standard diffusion cell setup. Light microscopy observations were used to determine ultrasound-induced structural changes in the cornea. For tobramycin, an increase in permeability for ultrasound- and sham-treated corneas was not statistically significant. Increase of 46%–126% and 32%–109% in corneal permeability was observed for sodium fluorescein and dexamethasone, respectively, with statistical significance (p < 0.05) achieved at all treatment parameter combinations (compared with sham treatments) except for 1-MHz ultrasound applications for dexamethasone experiments. This permeability increase was highest at 400 kHz and appeared to be higher at higher intensities applied. Histologic analysis showed structural changes that were limited to epithelial layers of cornea. In summary, ultrasound application provided enhancement of drug delivery, increasing the permeability of the cornea for the anti-inflammatory ocular drug dexamethasone. Future investigations are needed to determine the effectiveness and safety of this application in in vivo long-term survival studies. (E-mail: mnabili@gwu.edu)
Skin breakdown is a prevalent and costly medical condition worldwide, with the etiologic and healing processes being complex and multifactorial. Quantitative assessment of wound healing is challenging due to the subjective measurement of wound size and related characteristics. We propose that in vivo spectral reflectance measurements can serve as valuable clinical monitoring tool/device in the study of wound healing. We have designed a multi spectral camera able to acquire 18 wavelength sensitive images in a single snapshot. A lenslets array in front of a digital camera is combined with narrowband filters (bandwidth 10 nm) ranging from 460 to 886 nm. Images taken with the spectroscopic camera are composed of 18 identical sub-images, each carrying different spectral information, that can be used in the assessment of skin chromophores. A clinical trial based on a repeated measures design was conducted at the National Rehabilitation Hospital on 15 individuals to assess whether Poly Carboxy Methyl Glucose Sulfate (PCMGS, CACIPLIQ20), a bio-engineered component of the extracellular matrix of the skin, is effective at promoting healing of a variety of wounds. Multi spectral images collected at different wavelengths combined with optical skin models were used to quantify skin oxygen saturation and its relation to the traditional measures of wound healing.
The aim of this study was to determine whether a skin-specific bioengineered regenerating agent (RGTA) heparan sulphate mimetic (CACIPLIQ20) improves chronic wound healing. The design of this article is a prospective within-subject study. The setting was an urban hospital. Patients were 16 African-American individuals (mean age 42 years) with 22 wounds (mean duration 2.5 years) because of either pressure, diabetic, vascular or burn wounds. Two participants each were lost to follow-up or removed because of poor compliance, resulting in 18 wounds analysed. Sterile gauze was soaked with CACIPLIQ20 saline solution, placed on the wound for 5 min, then removed twice weekly for 4 weeks. Wounds were otherwise treated according to the standard of care. Twenty-two percent of wounds fully healed during the treatment period. Wounds showed a 15.2-18.1% decrease in wound size as measured by the vision engineering research group (VERG) digital wound measurement system and total PUSH scores, respectively, at 4 weeks (P = 0.014 and P = 0.003). At 8 weeks there was an 18-26% reduction in wound size (P = 0.04) in the remaining patients. Wound-related pain measured by the visual analogue pain scale and the wound pain scale declined 60% (P = 0.024) and 70% (P = 0.001), respectively. Patient and clinician satisfaction remained positive throughout the treatment period. It is concluded that treatment with CACIPLIQ20 significantly improved wound-related pain and may facilitate wound healing. Patient and clinician satisfaction remained high throughout the trial.
The ocular temperatures reached at higher frequencies were considered unsafe based on current recommendations. At a frequency of 400 kHz and intensity of 0.8 W/cm(2) (parameters shown in the authors' previous in vivo studies to be optimal for ocular drug delivery), the temperature increase was small enough to be considered safe inside different ocular tissues. However, the impact of orbital bone and tissue perfusion should be included in future modeling efforts to determine the safety of this method in the whole orbit especially regarding potential adverse optic nerve heating at the location of the bone.
In the model studied, N-PFLPs were shown to have biomechanical properties that were at least equivalent to those of the blade plate. The fatigue failures of O-PFLPs mirrored our clinical experience. Use of the N-PFLP might be a viable alternative fixation method for comminuted subtrochanteric femoral fractures that currently are treated with blade plates.
Rapid detection and diagnosis of a traumatic brain injury (TBI) can significantly improve the prognosis for recovery. Helmet-mounted sensors that detect impact severity based on measurements of acceleration or pressure show promise for aiding triage and transport decisions in active, field environments such as professional sports or military combat. The detected signals, however, report on the mechanics of an impact rather than directly indicating the presence and severity of an injury. We explored the use of cortical somatosensory evoked electroencephalographic potentials (SSEPs) to detect and track, in real-time, neural electrophysiological abnormalities within the first hour following head injury in an animal model. To study the immediate electrophysiological effects of injury in vivo, we developed an experimental paradigm involving focused ultrasound that permits continuous, real-time measurements and minimizes mechanical artifact. Injury was associated with a dramatic reduction of amplitude over the damaged hemisphere directly after the injury. The amplitude systematically improved over time but remained significantly decreased at one hour, compared with baseline. In contrast, at one hour there was a concomitant enhancement of the cortical SSEP amplitude evoked from the uninjured hemisphere. Analysis of the inter-trial electroencephalogram (EEG) also revealed significant changes in low-frequency components and an increase in EEG entropy up to 30 minutes after injury, likely reflecting altered EEG reactivity to somatosensory stimuli. Injury-induced alterations in SSEPs were also observed using noninvasive epidermal electrodes, demonstrating viability of practical implementation. These results suggest cortical SSEPs recorded at just a few locations by head-mounted sensors and associated multiparametric analyses could potentially be used to rapidly detect and monitor brain injury in settings that normally present significant levels of mechanical and electrical noise.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.