Overall, all patients significantly improved their QoL irrespective of the AF type in all questionnaires 3 months and 4 years after ablation. The increase in QoL was significantly greater in patients who underwent a successful ablation than patients with unsuccessful ablation in the AFSS, AFSC, and MDI questionnaire.
The data once again emphasized that AKI following endovascular aortic repair is an infrequent but morbid complication. For both open and endovascular repair of the abdominal and thoracic aorta, acute kidney injury portends a worse short and long-term outcome even if the patient does not become dialysis dependent.
Background—
Because of the risk of associated complications, femoral pseudoaneurysm (PSA) formation implies further treatment. Ultrasound-guided thrombin injection (UGTI) is becoming the accepted gold standard, but manual compression (MC) represents an established treatment option including PSAs not feasible for UGTI. This study aims to assess our experience in PSA treatment using MC or UGTI according to a potential algorithm based on morphological properties in a large patient cohort.
Methods and Results—
Between January 2007 and January 2011, a total of 432 PSAs were diagnosed in 29091 consecutive patients (1.49%) undergoing femoral artery catheterization. When compressible, small PSAs (<20 mm), PSAs without clearly definable neck, PSAs directly adjacent to vessels, and PSAs with concomitant arteriovenous fistula were referred to MC (n=145, 34%). All other PSAs were treated by UGTI (n=287, 66%). Follow-up duplex scans were performed within 12 to 14 hours after manual compression therapy and within 4 to 6 hours after UGTI or by the next morning and were available for 428 patients (99.1%). The overall success rate of our institutional therapeutic approach was 97.2%, which was achieved by 178 MC- and 357 UGTI-procedures, respectively. Procedural complications occurred in 5 cases (1.4%) after UGTI and in 3 cases (1.7%) after MC, respectively. The treatment algorithm was not successful in 12 patients, whereas 2 PSAs (0.5%) were successfully excluded by implantation of a covered stent-graft, and 10 patients necessitated surgical intervention (2.3%), which was associated with a high complication rate (30%).
Conclusions—
The presented treatment algorithm facilitates effective and safe PSA elimination.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.