Protein binding prevents uremic toxins from removal by conventional extracorporeal therapies leading to accumulation in maintenance dialysis patients. Weakening of the protein binding may enhance the dialytic elimination of these toxins. In ultrafiltration and equilibrium dialysis experiments, different measures to modify the plasma binding affinity and capacity were tested: (i), increasing the sodium chloride (NaCl) concentration to achieve a higher ionic strength; (ii), increasing the temperature; and (iii), dilution. The effects on the dissociation constant KD and the protein bound fraction of the prototypical uremic toxin indoxyl sulfate (IS) in plasma of healthy and uremic individuals were studied. Binding of IS corresponded to one site binding in normal plasma. KD increased linearly with the NaCl concentration between 0.15 (KD = 13.2 ± 3.7 µM) and 0.75 M (KD = 56.2 ± 2.0 µM). Plasma dilution further reduced the protein bound toxin fraction by lowering the protein binding capacity of the plasma. Higher temperatures also decreased the protein bound fraction of IS in human plasma. Increasing the NaCl concentration was effective to weaken the binding of IS also in uremic plasma: the protein bound fraction decreased from 89% ± 3% to 81% ± 3% at 0.15 and 0.75 M NaCl, respectively. Dilution and increasing the ionic strength and temperature enhance the free fraction of IS allowing better removal of the substance during dialysis. Applied during clinical dialysis, this may have beneficial effects on the long-term outcome of maintenance dialysis patients.
HDF-IPIS is technically and clinically feasible. More effective HDF-IPIS requires higher temporary plasma [Na ], but dialysate [Na ] has to be appropriately adapted to avoid sodium accumulation.
Metabolic stimuli, pressure, and fluid shear stress (FSS) are major mediators of vascular plasticity. The exposure of the vessel wall to increased laminar FSS is the main trigger of arteriogenesis, the remodelling of pre-existent arterio-arteriolar anastomoses to functional conductance arteries. In this study, we have used an in vitro bioreactor to investigate cell-specific interactions, molecular mechanisms as well as time-dependent effects under laminar FSS conditions. This bioreactor termed “artificial artery” can be used for screening potential arterio-protective substances, pro-arteriogenic factors, and for investigating biomarkers of cardiovascular diseases such as cardiac diseases. The bioreactor is built up out of 14 hollow fiber membranes colonized with endothelial cells (HUVECs) on the inside and smooth muscle cells (HUASMCs) on the outside. By means of Hoechst 33342 staining as well as immunocytochemistry of ß-catenin and α-smooth-muscle-actin, a microporous polypropylene membrane was characterized as being the appropriate polymer for co-colonization. Defined arterial flow conditions (0.1 N/m2 and 3 N/m2), metabolic exchange, and cross-talk of HUVECs and HUASMCs through hollow fibers mimic physiological in vivo conditions of the vasculature. Analysing mono- and co-culture secretomes by MALDI-TOF-TOF mass spectrometry, we could show that HUVECs secreted Up4A upon 3 N/m2. A constant cellular secretion of randomly chosen peptides verified viability of the “artificial artery” for a cultivation period up to five days. qRT-PCR analyses revealed an up-regulation of KLF2 and TIMP1 as mechano-regulated genes and demonstrated arterio-protective, homeostatic FSS conditions by a down-regulation of EDN1. Expression analyses of VWF and EDN1 furthermore confirmed that RNA of both cell types could separately be isolated without cross-contamination. CCND1 mRNA expression in HUVECs did not change upon FSS indicating a quiescent endothelial phenotype. Taken together, the “artificial artery” provides a solid in vitro model to test pharmacological active compounds for their impact on arterio-damaging or arterio-protective properties on vascular response.
The protein-bound uremic toxins para-cresyl sulfate (pCS) and indoxyl sulfate (IS) are associated with cardiovascular disease in chronic renal failure, but the effect of different dialysis procedures on their plasma levels over time is poorly studied. The present prospective, randomized, cross-over trial tested dialysis efficacy and monitored pre-treatment pCS and IS concentrations in 15 patients on low-flux and high-flux hemodialysis and high-convective volume postdilution hemodiafiltration over six weeks each. Although hemodiafiltration achieved by far the highest toxin removal, only the mean total IS level was decreased at week three (16.6 ± 12.1 mg/L) compared to baseline (18.9 ± 13.0 mg/L, p = 0.027) and to low-flux dialysis (20.0 ± 12.7 mg/L, p = 0.021). At week six, the total IS concentration in hemodiafiltration reached the initial values again. Concentrations of free IS and free and total pCS remained unaltered. Highest beta2-microglobulin elimination in hemodiafiltration (p < 0.001) led to a persistent decrease of the plasma levels at week three and six (each p < 0.001). In contrast, absent removal in low-flux dialysis resulted in rising beta2-microglobulin concentrations (p < 0.001). In conclusion, this trial demonstrated that even large differences in instantaneous protein-bound toxin removal by current extracorporeal dialysis techniques may have only limited impact on IS and pCS plasma levels in the longer term.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.