Aims: To evaluate occupational exposure to toxic pollutants at municipal waste incinerators (MWIs). Methods: Twenty nine male subjects working near the furnaces in two MWIs, and 17 subjects not occupationally exposed to combustion generated pollutants were studied. Individual air samples were taken throughout the shift; urine samples were collected before and after. Stationary air samples were taken near potential sources of emission. Results: Occupational exposure did not result in the infringement of any occupational threshold limit value. Atmospheric exposure levels to particles and metals were 10-100 times higher in MWIs than at the control site. The main sources were cleaning operations for particles, and residue transfer and disposal operations for metals. MWI workers were not exposed to higher levels of polycyclic aromatic hydrocarbons than workers who are routinely in contact with vehicle exhaust. The air concentrations of volatile organic compounds and aldehydes were low and did not appear to pose any significant threat to human health. Only the measurement of chlorinated hydrocarbon levels would seem to be a reliable marker for the combustion of plastics. Urine metal levels were significantly higher at plant 1 than at plant 2 because of high levels of pollutants emanating from one old furnace.
Many workers and also the general population are exposed to polycyclic aromatic hydrocarbons (PAHs), and benzo[a]pyrene (BaP) was recently classified as carcinogenic for humans (group 1) by the International Agency for Research on Cancer. Biomonitoring of PAHs exposure is usually performed by urinary 1-hydroxypyrene (1-OHP) analysis. 1-OHP is a metabolite of pyrene, a non-carcinogenic PAH. In this work, we developed a very simple but highly sensitive analytical method of quantifying one urinary metabolite of BaP, 3-hydroxybenzo[a]pyrene (3-OHBaP), to evaluate carcinogenic PAHs exposure. After hydrolysis of 10 mL urine for two hours and concentration by automated off-line solid phase extraction, the sample was injected in a column-switching high-performance liquid chromatography fluorescence detection system. The limit of quantification was 0.2 pmol L(-1) (0.05 ng L(-1)) and the limit of detection was estimated at 0.07 pmol L(-1) (0.02 ng L(-1)). Linearity was established for 3-OHBaP concentrations ranging from 0.4 to 74.5 pmol L(-1) (0.1 to 20 ng L(-1)). Relative within-day standard deviation was less than 3% and relative between-day standard deviation was less than 4%. In non-occupationally exposed subjects, median concentrations for smokers compared with non-smokers were 3.5 times higher for 1-OHP (p<0.001) and 2 times higher for 3-OHBaP (p<0.05). The two urinary biomarkers were correlated in smokers (ρ=0.636; p<0.05; n=10) but not in non-smokers (ρ=0.09; p>0.05; n=21).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.