Aim: To characterize Bordetella pertussis vaccine strains in comparison with current circulating bacteria.
Methods and Results: Genomic and proteomic analyses of Bp137 were performed in comparison with other vaccine strains used in Latin America (Bp509 and Bp10536) and with the clinical Argentinean isolate Bp106. Tohama I strain was used as reference strain. Pulse‐field gel electrophoresis (PFGE) and pertussis toxin promoter (ptxP) sequence analysis revealed that Bp137 groups with Bp509 in PFGE group III and contains ptxP2 sequence. Tohama I (group II) and Bp10536 (group I) contain ptxP1 sequence, while Bp106 belongs to a different PFGE cluster and contains ptxP3. Surface protein profiles diverged in at least 24 peptide subunits among the studied strains. From these 24 differential proteins, Bp10536 shared the expression of ten proteins with Tohama I and Bp509, but only three with Bp137. In contrast, seven proteins were detected exclusively in Bp137 and Bp106.
Conclusions: Bp137 showed more features in common with the clinical isolate Bp106 than the other vaccine strains here included.
Significance and Impact of the Study: The results presented show that the old strains included in vaccines are not all equal among them. These findings together with the data of circulating bacteria should be taken into account to select the best vaccine to be included in a national immunization programme.
Systolic blood pressure (SBP) is frequently measured in rats by the tail cuff method, which usually comprises pulse/flow disappearance and reappearance during cuff inflation (Inf) and deflation (Def), separated by an interval between cycles (IBC). Although Def values are habitually used to estimate SBP, in 58 Wistar rats we found (Def-Inf) to be -6 +/- 1 mmHg, indicating that Def < Inf in most cases. When the IBC was lengthened to 2 min, (Def-Inf) was increased to -17 +/- 2 mmHg, indicating the probable accumulation of a vasodilating metabolite. This increase of (Def-Inf) was prevented by papaverine, indicating its relation to smooth muscle contractility. Adrenergic blockade did not prevent the increase of (Def-Inf), but pretreatment with L-NAME decreased it to -5 +/- 2 mmHg (p < 0.05). Simultaneous measurement of SBP by tail-cuff method and carotid cannulation revealed that the Inf value was the most accurate estimation of intravascular SBP. We conclude that: (1) the Inf value should be taken as representative of SBP, since depending on the duration of suprasystolic compression the Def value can underestimate it, and (2) nitric oxide accumulation due to flow deprivation was the main cause of SBP underestimation by Def values.
Los principales objetivos a alcanzar fueron los siguientes: a) Estudio de las condiciones óptimas para la toma de presión, sobre todo temperatura e inmovilización del animal. b) Sistemas especiales para controlar la presión en el manguito oclusor de flujo. c) Adaptación del sistema de adquisición para la toma y procesamiento de las señales de presión. d) Toma de presión por métodos directos, utilizando catéteres flexibles, implantados mediante un equipamiento que permita el libre movimiento del animal. e) Evaluación y comparación de sistemas menos convencionales de detección del pulso arterial, como el fotoeléctrico.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.