Background: Idiopathic normal pressure hydrocephalus and PSP share several clinical and radiological features, making differential diagnosis, at times, challenging. Objectives: To differentiate idiopathic normal pressure hydrocephalus from PSP using MR volumetric and linear measurements. Methods: Twenty-seven idiopathic normal pressure hydrocephalus patients, 103 probable PSP patients, and 43 control subjects were consecutively enrolled. Automated ventricular volumetry was performed using Freesurfer 6 on MR T 1-weighted images. Linear measurements, such as callosal angle and a new measure, termed MR Hydrocephalic Index, were calculated on MR T 1-weighted images. Receiver operating characteristic analyses were used for differentiating between patient groups. Generalizability and reproducibility of the results were validated, dividing each participant group in two cohorts used as training and testing subsets. Results: Ventricular volumes and linear measurements (callosal angle and Magnetic Resonance Hydrocephalic Index) revealed greater ventricular enlargement in patients with idiopathic normal pressure hydrocephalus than in PSP patients and controls. PSP patients had ventricular volume larger than controls. Automated ventricular volumetry and Magnetic Resonance Hydrocephalic Index were the most accurate measures (98.5%) in differentiating patients with idiopathic normal pressure hydrocephalus from PSP patients, whereas callosal angle misclassified several PSP patients and showed low positive predictive value (70.0%) in differentiating between these two diseases. All measurements accurately differentiated idiopathic normal pressure hydrocephalus patients from controls. Accuracy values obtained in the training set (automated ventricular volumetry, 98.4%; Magnetic Resonance Hydrocephalic Index, 98.4%; callosal angle, 87.5%) were confirmed in the testing set. Conclusions: Our study demonstrates that AVV and Magnetic Resonance Hydrocephalic Index were the most accurate measures for differentiation between idiopathic normal pressure hydrocephalus and PSP patients. Magnetic Resonance Hydrocephalic Index is easy to measure and can be used in clinical practice to prevent misdiagnosis and ineffective shunt procedures in idiopathic normal pressure hydrocephalus mimics.
The demand of glucose monitoring devices and even of updated guidelines for the management of diabetic patients is dramatically increasing due to the progressive rise in the prevalence of diabetes mellitus and the need to prevent its complications. Even though the introduction of the first glucose sensor occurred decades ago, important advances both from the technological and clinical point of view have contributed to a substantial improvement in quality healthcare. This review aims to bring together purely technological and clinical aspects of interest in the field of glucose devices by proposing a roadmap in glucose monitoring and management of patients with diabetes. Also, it prospects other biological fluids to be examined as further options in diabetes care, and suggests, throughout the technology innovation process, future directions to improve the follow-up, treatment, and clinical outcomes of patients.
A BS TRACT: Background: Enlargement of the third ventricle has been reported in atypical parkinsonism. We investigated whether the measurement of third ventricle width could distinguish Parkinson's disease (PD) from progressive supranuclear palsy (PSP). Methods: We assessed a new MR T1-weighted measurement (third ventricle width/internal skull diameter) in a training cohort of 268 participants (98 PD, 73 PSP, 98 controls from our center) and in a testing cohort of 291 participants (82 de novo PD patients and 133 controls from the Parkinson's Progression Markers Initiative, 76 early-stage PSP from an international research group). PD diagnosis was confirmed after a 4-year follow-up. Diagnostic performance of the third ventricle/internal skull diameter was assessed using receiver operating characteristic curve with bootstrapping; the area under the curve of the training cohort was compared with the area under the curve of the testing cohort using the De Long test. Results: In both cohorts, third ventricle/internal skull diameter values did not differ between PD and controls but were significantly lower in PD than in PSP patients (P < 0.0001). In PD, third ventricle/internal skull diameter values did not change significantly between baseline and follow-up evaluation. Receiver operating characteristic analysis accurately differentiated PD from PSP in the training cohort (area under the curve, 0.94; 95% CI, 91.1-97.6; cutoff, 5.72) and
Background Differentiating progressive supranuclear palsy‐parkinsonism (PSP‐P) from Parkinson's disease (PD) is clinically challenging. Objective This study aimed to develop an automated Magnetic Resonance Parkinsonism Index 2.0 (MRPI 2.0) algorithm to distinguish PSP‐P from PD and to validate its diagnostic performance in two large independent cohorts. Methods We enrolled 676 participants: a training cohort (n = 346; 43 PSP‐P, 194 PD, and 109 control subjects) from our center and an independent testing cohort (n = 330; 62 PSP‐P, 171 PD, and 97 control subjects) from an international research group. We developed a new in‐house algorithm for MRPI 2.0 calculation and assessed its performance in distinguishing PSP‐P from PD and control subjects in both cohorts using receiver operating characteristic curves. Results The automated MRPI 2.0 showed excellent performance in differentiating patients with PSP‐P from patients with PD and control subjects both in the training cohort (area under the receiver operating characteristic curve [AUC] = 0.93 [95% confidence interval, 0.89–0.98] and AUC = 0.97 [0.93–1.00], respectively) and in the international testing cohort (PSP‐P versus PD, AUC = 0.92 [0.87–0.97]; PSP‐P versus controls, AUC = 0.94 [0.90–0.98]), suggesting the generalizability of the results. The automated MRPI 2.0 also accurately distinguished between PSP‐P and PD in the early stage of the diseases (AUC = 0.91 [0.84–0.97]). A strong correlation (r = 0.91, P < 0.001) was found between automated and manual MRPI 2.0 values. Conclusions Our study provides an automated, validated, and generalizable magnetic resonance biomarker to distinguish PSP‐P from PD. The use of the automated MRPI 2.0 algorithm rather than manual measurements could be important to standardize measures in patients with PSP‐P across centers, with a positive impact on multicenter studies and clinical trials involving patients from different geographic regions. © 2022 The Authors. Movement Disorders published by Wiley Periodicals LLC on behalf of International Parkinson and Movement Disorder Society
We developed and investigated a particular geometry of transducers, emulating the shape of bats’ cochlea, to transmit and receive ultrasounds in the air. Their design involved the use of polyvinylidene fluoride (PVDF) as a piezoelectric material, thanks to its excellent conformability and flexibility. This material offers the primary requirements for sensing devices in applications such as sonar system or energy harvesting technology. The piezo film was folded according to both the Archimedean and Fibonacci spirals, and their performances were investigated in the frequency range from 20 kHz up to more than 80 kHz. The finite element analysis (FEA) of the proposed transducers highlighted the presence of multiple resonance vibrations, proved by the experimental measurements of the equivalent electric impedance and frequency response. Far-field radiation patterns demonstrated, horizontally and vertically, omnidirectional properties both as transmitters and receivers. All was enough to establish the best validity of the spiral shaped transducers for applications based on the bio sonar principle.
Apnea in the pediatric population is associated with increased morbidity and mortality in a large number of developed as well as developing countries. It is even more prominent in preterm newborn infants and is commonly referred to as apnea of prematurity. Its current diagnosis and therapy involve the use of traditional technologies, which often result in discomfort to the infants due to the use of invasive devices attached to their sensitive skin, especially in overnight clinical sleep analysis (for over a 12- or 24-h period). Emerging trends for the point-of-care diagnosis of this sleep disorder are focused on the design of integrated devices for less complex and noninvasive monitoring. This paper presents a review of the state of the art of clinical technologies and methodologies for sleep apnea detection and their pros and cons, with particular focus on their working principles and relevance to pediatrics. Moreover, an in-depth discussion on emerging future technologies envisioned to be integral parts of the daily home-based applications is included in the paper.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.