Modeling different treatment options before a procedure is performed is a promising approach for surgical decision making and patient care in heart valve disease. This study investigated the hemodynamic impact of different prostheses through patient-specific MRI-based CFD simulations. Ten time-resolved MRI data sets with and without velocity encoding were obtained to reconstruct the aorta and set hemodynamic boundary conditions for simulations. Aortic hemodynamics after virtual valve replacement with a biological and mechanical valve prosthesis were investigated. Wall shear stress (WSS), secondary flow degree (SFD), transvalvular pressure drop (TPD), turbulent kinetic energy (TKE), and normalized flow displacement (NFD) were evaluated to characterize valve-induced hemodynamics. The biological prostheses induced significantly higher WSS (medians: 9.3 vs. 8.6 Pa, P 5 0.027) and SFD (means: 0.78 vs. 0.49, P 5 0.002) in the ascending aorta, TPD (medians: 11.4 vs. 2.7 mm Hg, P 5 0.002), TKE (means: 400 vs. 283 cm 2 /s 2 , P 5 0.037), and NFD (means: 0.0994 vs. 0.0607, P 5 0.020) than the mechanical prostheses. The differences between the prosthesis types showed great interpatient variability, however. Given this variability, a patientspecific evaluation is warranted. In conclusion, MRI-based CFD offers an opportunity to assess the interactions between prosthesis and patient-specific boundary conditions, which may help in optimizing surgical decision making and providing additional guidance to clinicians.
Self-inflating bags did not reliably provide the desired PEEP of 5 cmH (2)O, whereas T-piece resuscitators did reliably provide the set PEEP-level, with less variability. When using self-inflating bags with PEEP-valves, neonatologists should check the equipment regarding the reliability of PEEP provision.
BackgroundIn aortic coarctation, current guidelines recommend reducing pressure gradients that exceed given thresholds. From a physiological standpoint this should ideally improve the energy expenditure of the heart and thus prevent long term organ damage.ObjectivesThe aim was to assess the effects of interventional treatment on external and internal heart power (EHP, IHP) in patients with aortic coarctation and to explore the correlation of these parameters to pressure gradients obtained from heart catheterization.MethodsIn a collective of 52 patients with aortic coarctation 25 patients received stenting and/or balloon angioplasty, and 20 patients underwent MRI before and after an interventional treatment procedure. EHP and IHP were computed based on catheterization and MRI measurements. Along with the power efficiency these were combined in a cardiac energy profile.ResultsBy intervention, the catheter gradient was significantly reduced from 21.8±9.4 to 6.2±6.1mmHg (p<0.001). IHP was significantly reduced after intervention, from 8.03±5.2 to 4.37±2.13W (p < 0.001). EHP was 1.1±0.3 W before and 1.0±0.3W after intervention, p = 0.044. In patients initially presenting with IHP above 5W intervention resulted in a significant reduction in IHP from 10.99±4.74 W to 4.94±2.45W (p<0.001), and a subsequent increase in power efficiency from 14 to 26% (p = 0.005). No significant changes in IHP, EHP or power efficiency were observed in patients initially presenting with IHP < 5W.ConclusionIt was demonstrated that interventional treatment of coarctation resulted in a decrease in IHP. Pressure gradients, as the most widespread clinical parameters in coarctation, did not show any correlation to changes in EHP or IHP. This raises the question of whether they should be the main focus in coarctation interventions. Only patients with high IHP of above 5W showed improvement in IHP and power efficiency after the treatment procedure.Trial Registrationclinicaltrials.gov NCT02591940
Aims Although heart failure (HF) is a leading cause for hospitalization and mortality, normalized and comparable non-invasive assessment of haemodynamics and myocardial action remains limited. Moreover, myocardial deformation has not been compared between the guideline-defined HF entities. The distribution of affected and impaired segments within the contracting left ventricular (LV) myocardium have also not been compared. Therefore, we assessed myocardial function impairment by strain in patients with HF and control subjects by magnetic resonance imaging after clinically phenotyping these patients. Methods and results This prospective study conducted at two centres in Germany between 2017 and 2018 enrolled stable outpatient subjects with HF [n = 56, including HF with reduced ejection fraction (HFrEF), HF with mid-range ejection fraction (HFmrEF), and HF with preserved ejection fraction (HFpEF)] and a control cohort (n = 12). Parameters assessed included measures for external myocardial function, for example, cardiac index and myocardial deformation measurements by cardiovascular magnetic resonance imaging, left ventricular global longitudinal strain (GLS), the global circumferential strain (GCS) and the regional distribution of segment deformation within the LV myocardium, as well as basic phenotypical characteristics. Comparison of the cardiac indices at rest showed no differences neither between the HF groups nor between the control group and HF patients (one-way ANOVA P = 0.70). The analysis of the strain data revealed differences between all groups in both LV GLS (One-way ANOVA:
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.