Background-Three trials demonstrated recently that a long detection window reduces implantable cardioverter-defibrillator (ICD) therapy in primary prevention patients. Avoid Delivering Therapies for Nonsustained Arrhythmias in ICD Patients III (ADVANCE III) was the only trial that enrolled both primary and secondary prevention patients. Methods and Results-Of the 1902 patients enrolled in the ADVANCE III trial, 477 received a defibrillator for secondary prevention; 248 patients were randomly assigned to a long detection setting (30 of 40 intervals) and 229 to the nominal setting (18 of 24 intervals) for ventricular arrhythmias with cycle length ≤320 ms. Eight-five percent of patients were men, with a mean age of 65±12 years, a previous history of ventricular fibrillation in 37% of the cases, and a mean ejection fraction of 38±13%. The ICD device mix was 37% single chamber, 47% dual chamber, and 16% triple chamber. Over a median period of 12 months, the long detection period was associated with a 25% reduction in the number of overall therapies (115.6 versus 86.8 per 100 patient-years; incidence rate ratio, 0.75; 95% confidence interval, 0.
Among patients implanted with a VVI ICD, programming with the long detection interval significantly reduced appropriate therapies, shocks, and all-cause mortality. (Avoid DeliVering TherApies for Non-sustained Arrhythmias in ICD PatiEnts III [ADVANCEIII]; NCT00617175).
AimsA long-detection interval (LDI) (30/40 intervals) has been proved to be superior to a standard-detection interval (SDI) (18/24 intervals) in terms of reducing unnecessary implantable cardioverter defibrillator (ICD) therapies. To better evaluate the different impact of LDI and anti-tachycardia pacing (ATP) on reducing painful shocks, we assessed all treated episodes in the ADVANCE III trial.Methods and resultsA total of 452 fast (200 ms < cycle length ≤ 320 ms) arrhythmic episodes were recorded: 284 in 138 patients in the SDI arm and 168 in 82 patients in the LDI arm (106/452 inappropriate detections). A total of 346 fast ventricular tachycardias (FVT) were detected in 169 patients: 208 in 105 patients with SDI and 138 in 64 patients with LDI. Setting LDI determined a significant reduction in appropriate but unnecessary therapies [208 in SDI vs. 138 in LDI; incidence rate ratio (IRR): 0.61 (95% CI 0.45–0.83), P = 0.002]. Anti-tachycardia pacing determined another 52% reduction in unnecessary shocks [208 in SDI with hypothetical shock-only programming vs. 66 in LDI with ATP; IRR: 0.37 (95% CI 0.25–0.53, P < 0.001)]. The efficacy of ATP in terminating FVT was 63% in SDI and 52% in LDI (P = 0.022). No difference in the safety profile (acceleration/degeneration and death/cardiovascular hospitalizations) was observed between the two groups.ConclusionThe combination of LDI and ATP during charging is extremely effective and significantly reduces appropriate but unnecessary therapies. The use of LDI alone yielded a 39% reduction in appropriate but unnecessary therapies; ATP on top of LDI determined another 52% reduction in unnecessary shocks. The strategy of associating ATP and LDI could be considered in the majority of ICD recipients.
ICD is effective in nearly half the patient population; however, the early and late complication rates are high. Although the number of unnecessary ICD shocks and reimplant procedures may be lowered by modern programming and increased longevity of newer ICD generators, other adverse events are less likely to be reduced.
Dual-site right ventricular pacing in comparison to RVA pacing improved cardiac systolic function. RVOT appeared to be more advantageous than RVA pacing in patients with impaired, but not in those with preserved left ventricular function. No clear hemodynamic benefit of DuRV in comparison to RVOT pacing in patients with impaired systolic function was observed.
ObjectiveIn implantable cardiac defibrillators (ICDs), long-detection times safely reduce unnecessary and inappropriate therapies. We aimed to evaluate ICD treatment of ventricular arrhythmias in women, compared with men, also taking into account ICD detection.MethodsThe Advance III trial randomised patients implanted with an ICD for primary or secondary prevention in two arms—long and nominal ventricular arrhythmias detection times before therapy delivering (number of intervals needed to detect (NID) 30/40 and 18/24, respectively). The main endpoint of this post hoc analysis was the incidence of ICD therapies evaluated through Kaplan-Meier method and univariate Cox regression models.ResultsOverall, 1902 patients (304 women, 65±11 years) were randomised. Women showed a lower risk of ICD therapy (HR 0.63, 95% CI 0.43 to 0.93, p=0.022); this difference was observed only in the long-detection arm (HR 0.37, p=0.013) and not in the short detection arm (HR 0.82, p=0.414). No significant sex differences were observed concerning inappropriate therapies and mortality rate. Long-detection settings significantly reduced overall ICD therapies and appropriate ICD therapies, both in women (overall HR 0.31, p=0.007; appropriate HR 0.33, p=0.033) and in men (overall HR 0.69, p=0.006; appropriate HR 0.73, p=0.048).ConclusionsIn patients with ICDs, the strategy of setting a long-detection time to treat ventricular arrhythmias (NID 30/40) reduces overall delivered therapies, both in women and men, when compared with nominal setting (NID 18/24). The reduction was significantly higher in women. Overall, women were less likely to experience ICD therapies than men; this result was only observed in the long-detection arm.Clinical trial registrationNCT00617175.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.