Background While many authors have recommended surgery for patients with persistent symptoms of external snapping hip, it is unclear which one best relieves symptoms. Concerns with iliotibial band (ITB)-modifying techniques include altering the shape of the lateral thigh and overload of the contralateral abduction mechanism. We describe a new endoscopic technique that decreases the tension of the ITB complex by releasing the femoral insertion of the gluteus maximus tendon (GMT). Description of Technique Via an endoscopic approach, we tenotomize the GMT near its insertion at the linea aspera through two trochanteric portals, developing a space beneath the ITB. Methods We reviewed eight patients (nine hips) with external snapping hip nonresponsive to nonoperative treatment treated by endoscopic GMT release. There were seven women (one bilateral) and one man, with a mean ± SD age of 35 ± 13.1 years (range, 18-55 years). Mean symptom duration was 36 ± 20.3 months (range, 16-84 months). Minimum followup was 22 months (mean, 32 ± 9.3 months; range, 22-45 months). Results Snapping and pain resolved in seven patients after the initial procedure. We performed one revision procedure with complete relief of symptoms. All eight patients returned to their previous level of activity. Average modified Harris hip score was 61 points (range, 45-70 points) preoperatively and 78 points (range, 62-93 points) at latest followup. We observed no neurovascular complications. Conclusions Our small series suggests endoscopic release of the GMT resolves pain and snapping symptoms in most patients. Level of Evidence Level IV, therapeutic study. See Instructions for Authors for a complete description of levels of evidence.
Recent literature demonstrates that the main risk factors for a two-stage exchange failure are as follows: hemodialysis, obesity, multiple previous procedures, diabetes mellitus, corticosteroid therapy, hypoalbuminemia, immunosuppression, rheumatological conditions, coagulation disorders, and infection due to multidrug-resistant (MDR) bacteria or fungal species. Regarding microorganisms, besides Staphylococcus aureus, Streptococcus spp., Enterobacteriaceae species such as Klebsiella pneumoniae and Enterobacter sp., Pseudomonas aeruginosa, or Acinetobacter baumannii, and fungus including Candida sp. are also considered risk factors for a two-stage exchange failure. Resection arthroplasty, arthrodesis, and amputation have a limited role. Chronic suppression is an option for high-risk patients or unfeasible reconstruction. In summary, we report the main risk factors for a two-stage exchange failure and alternative procedures when it occurs. Future research on patient-specific risk factors for a two-stage exchange may aid surgical decision-making and optimization of outcomes.
Purpose of Review
Augmented reality (AR) is becoming increasingly popular in modern-day medicine. Computer-driven tools are progressively integrated into clinical and surgical procedures. The purpose of this review was to provide a comprehensive overview of the current technology and its challenges based on recent literature mainly focusing on clinical, cadaver, and innovative sawbone studies in the field of orthopedic surgery. The most relevant literature was selected according to clinical and innovational relevance and is summarized.
Recent Findings
Augmented reality applications in orthopedic surgery are increasingly reported. In this review, we summarize basic principles of AR including data preparation, visualization, and registration/tracking and present recently published clinical applications in the area of spine, osteotomies, arthroplasty, trauma, and orthopedic oncology. Higher accuracy in surgical execution, reduction of radiation exposure, and decreased surgery time are major findings presented in the literature.
Summary
In light of the tremendous progress of technological developments in modern-day medicine and emerging numbers of research groups working on the implementation of AR in routine clinical procedures, we expect the AR technology soon to be implemented as standard devices in orthopedic surgery.
Diagnoses of hip and pelvis disorders are based on the detailed medical history, physical examination and laboratory tests, as appropriate for each condition. Plain radiography is still the initial examination of choice and, because of its importance, there is a need to standardize radiographic studies, both in relation to execution and in radiographic series, according to the different pathological conditions. The aim of this paper was to propose standardization for the main radiographic views of the hip and pelvis, and with regard to performing specific series for different pathological conditions, and to provide technical guidance for achieving these aims.
Arthroscopic treatment of femoroacetabular impingement, at five years follow-up, revealed good results in terms of improved function, pain relief and satisfaction.
Objectiveto translate the Hip Outcome Score clinical evaluation questionnaire into Portuguese and culturally adapt it for Brazil.Methodsthe Hip Outcome Score questionnaire was translated into Portuguese following the methodology consisting of the steps of translation, back-translation, pretesting and final translation.Resultsthe pretesting was applied to 30 patients with hip pain without arthrosis. In the domain relating to activities of daily living, there were no difficulties in comprehending the translated questionnaire. In presenting the final translation of the questionnaire, all the questions were understood by more than 85% of the individuals.Conclusionthe Hip Outcome Score questionnaire was translated and adapted to the Portuguese language and can be used in clinical evaluation on the hip. Additional studies are underway with the objective of evaluating the reproducibility and validity of the Brazilian translation.
Objective: The purpose of this study is to evaluate the short-term follow-up results of arthroscopic treatment of femoroacetabular impingement. Our hypothesis is that arthroscopic treatment results are favorable. Methods: Between August 2003 and August 2007, 28 hips had femoroacetabular impingement treated by hip arthroscopy. The mean age was 34 years, with mean follow-up period of 27 months. Clinical results were graded with the modified Harris hip score, which was measured pre- and postoperatively. Patients had also their internal rotation analyzed. These parameters were calculated by using Wilcoxon's t test for analysis of nonparametric paired samples performed. Results: The mean preoperative Harris Hip Score was 54.2, improving to 94.8 postoperatively (p<0,001). The mean increase was 37.5 points. We had 4 good results (15%) and 24 excellent results (85%). Preoperatively, the patients had a mean internal rotation of 17°, and, postoperatively, 36°. The average internal rotation increase was 19° (p<0,001). Conclusions: The arthroscopic treatment of femoroacetabular impingement presents satisfactory results.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.