Brain tissue analysis is highly desired in neurosurgery, such as tumor resection. To guarantee best life quality afterward, exact navigation within the brain during the surgery is essential. So far, no method has been established that perfectly fulfills this need. Optical coherence tomography (OCT) is a promising three-dimensional imaging tool to support neurosurgical resections. We perform a preliminary study toward in vivo brain tumor removal assistance by investigating meningioma, healthy white, and healthy gray matter. For that purpose, we utilized a commercially available OCT device (Thorlabs Callisto) and measured eight samples of meningioma, three samples of healthy white, and two samples of healthy gray matter ex vivo directly after removal. Structural variations of different tissue types, especially meningioma, can already be seen in the raw OCT images. Nevertheless, an automated differentiation approach is desired, so that neurosurgical guidance can be delivered without a-priori knowledge of the surgeon. Therefore, we employ different algorithms to extract texture features and apply pattern recognition methods for their classification. With these postprocessing steps, an accuracy of nearly 98% was found.
Purpose A precise resection of the entire tumor tissue during surgery for brain metastases is essential to reduce local recurrence. Conventional intraoperative imaging techniques all have limitations in detecting tumor remnants. Therefore, there is a need for innovative new imaging methods such as optical coherence tomography (OCT). The purpose of this study is to discriminate brain metastases from healthy brain tissue in an ex vivo setting by applying texture analysis and machine learning algorithms for tissue classification to OCT images. Methods Tumor and healthy tissue samples were collected during resection of brain metastases. Samples were imaged using OCT. Texture features were extracted from B-scans. Then, a machine learning algorithm using principal component analysis (PCA) and support vector machines (SVM) was applied to the OCT scans for classification. As a gold standard, an experienced pathologist examined the tissue samples histologically and determined the percentage of vital tumor, necrosis and healthy tissue of each sample. A total of 14.336 B-scans from 14 tissue samples were included in the classification analysis. Results We were able to discriminate vital tumor from healthy brain tissue with an accuracy of 95.75%. By comparing necrotic tissue and healthy tissue, a classification accuracy of 99.10% was obtained. A generalized classification between brain metastases (vital tumor and necrosis) and healthy tissue was achieved with an accuracy of 96.83%. Conclusions An automated classification of brain metastases and healthy brain tissue is feasible using OCT imaging, extracted texture features and machine learning with PCA and SVM. The established approach can prospectively provide the surgeon with additional information about the tissue, thus optimizing the extent of tumor resection and minimizing the risk of local recurrences.
OBJECTIVEBecause of their complex topography, long courses, and small diameters, peripheral nerves are challenging structures for radiological diagnostics. However, imaging techniques in the area of peripheral nerve diseases have undergone unexpected development in recent decades. They include MRI and high-resolution sonography (HRS). Yet none of those imaging techniques reaches a resolution comparable to that of histological sections. Fascicles are the smallest discernable structure. Optical coherence tomography (OCT) is the first imaging technique that is able to depict a nerve’s ultrastructure at micrometer resolution. In the current study, the authors present an in vivo assessment of human peripheral nerves using OCT.METHODSOCT measurement was performed in 34 patients with different peripheral nerve pathologies, i.e., nerve compression syndromes. The nerves were examined during surgery after their exposure. Only the sural nerve was twice examined ex vivo. The Thorlabs OCT systems Callisto and Ganymede were used. For intraoperative use, a hand probe was covered with a sterile foil. Different postprocessing imaging techniques were applied and evaluated. In order to highlight certain structures, five texture parameters based on gray-level co-occurrence matrices were calculated according to Haralick.RESULTSThe intraoperative use of OCT is easy and intuitive. Image artifacts are mainly caused by motion and the sterile foil. If the artifacts are kept at a low level, the hyporeflecting bundles of nerve fascicles and their inner parts can be displayed. In the Haralick evaluation, the second angular moment is most suitable to depict the connective tissue.CONCLUSIONSOCT is a new imaging technique that has shown promise in peripheral nerve surgery for particular questions. Its resolution exceeds that provided by recent radiological possibilities such as MRI and HRS. Since its field of view is relatively small, faster acquisition times would be highly desirable and have already been demonstrated by other groups. Currently, the method resembles an optical biopsy and can be a supplement to intraoperative sonography, giving high-resolution insight into a suspect area that has been located by sonography in advance.
Abstract:In this paper we demonstrate that optical coherence tomography (OCT) is a powerful tool for the non-destructive investigation of transparent coatings on metal substrates. We show that OCT provides additional information which the common practice electrical impedance spectroscopy (EIS) cannot supply. First, coating layer thicknesses were measured and compared with reference measurements using a magnetic inductive (MI) measurement technique. After this validation of the OCT measurements, a customized sectioned sample was created to test the possibility to measure coating thicknesses with underlying corrosion, which cannot be analyzed accurately by MI or EIS measurements. Finally, we demonstrate the benefit of OCT on a standard sample. The OCT measurements provide the correct coating layer thickness with high lateral resolution and even enable metal and corrosion layers to be distinguished from each other.
While it is known that the degenerated intervertebral disc (IVD) is one of the primary reasons for low-back pain and subsequent need for medical care, there are currently no established effective methods for direct treatment. Nuclear factor-κB (NF-κB) is a transcription factor that regulates various genes’ expression, among which are inflammatory cytokines, in many tissues including the IVD. NF-κB decoy is an oligodeoxynucleotide containing the NF-κB binding site that entraps NF-κB subunits, resulting in suppression of NF-κB activity. In the present preclinical study, NF-κB decoy was injected into degenerated IVDs using the rabbit anular-puncture model. In terms of distribution, NF-κB decoy persisted in the IVDs up to at least 4 weeks after injection. The remaining amount of NF-κB decoy indicated that it fit a double-exponential-decay equation. Investigation of puncture-caused degeneration of IVDs showed that NF-κB decoy injection recovered, dose-dependently, the reduced disc height that was associated with reparative cell cloning and morphological changes, as assessed through histology. Gene expression, by quantitative real-time polymerase chain reaction (qRT-PCR), showed that NF-κB decoy attenuated inflammatory gene expression, such as that of interleukin-1 and tumor necrosis factor-α, in rabbit degenerated IVDs. NF-κB decoy also reduced the pain response as seen using the “pain sensor” nude rat xenograft-radiculopathy model. This is the first report demonstrating that NF-κB decoy suppresses the inflammatory response in degenerated IVDs and restores IVD disc height loss. Therefore, the intradiscal injection of NF-κB decoy may have the potential as an effective therapeutic strategy for discogenic pain associated with degenerated IVDs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.