When planning to place implants in the posterior region of the maxilla, the location of the maxillary sinus floor is influencing the available bone height and the implant length chosen. The aim of the present study was to evaluate in vitro the spiral tomographic technique that could be used for pre-operative implant planning. Tomographs were taken of 6 dry human skulls using the Cranex Tome multifunctional unit (Orion Corporation Soredex, Helsinki, Finland). Three sites were selected in the left posterior maxilla and marked with gutta percha meaning a total of 18 sites (6 x 3 = 18) for interpretation. Bone height and width were measured on the tomographs and after sectioning also on the skulls. The values obtained from the measurements on tomographs were divided by an enlargement factor of 1.5 (as defined by the manufacturer) and then compared with those from the real measurements on the skulls. Real measurements were on average 0.24 mm (SD 0.19) lower than the tomographic measurements (P < 0.05). From the present results it could be concluded that spiral tomography using the recently developed Cranex Tome reveals sufficient information and detail for pre-operative planning of a limited edentulous region.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.