Subclinical visual dysfunction was observed in patients with PD with good structural-functional correlation. GCL-IPL thinning may be a more reliable parameter than RNFL thickness for structural alterations of the retina in patients with PD.
PurposeTo compare femtosecond laser-assisted capsulotomy with conventional manual capsulorhexis in cases of white cataract.Patients and methodsThe prospective comparative study enrolled 80 eyes (80 patients) with white cataract that underwent either femtosecond laser-assisted cataract surgery (Group I, n=40) or conventional manual phacoemulsification (Group II, n=40) at a tertiary care ophthalmic institution. The groups were divided based on the patient’s choice and affordability of the procedure. Capsulotomy/capsulorhexis was evaluated in terms of size, circularity index (4Π [area/perimeter2]), intraocular lens coverage, and continuity. Each group was further subdivided based on the release of white milky fluid on initiation of the capsulotomy/capsulorhexis, and the “fluid” cases were compared with the “no-fluid” cases. The primary outcome measure was capsulotomy/capsulorhexis characteristics in the two groups. The secondary outcome measures were intraoperative phacoemulsification parameters, intraoperative complications, and postoperative visual acuity.ResultsThe size of the capsulotomy/capsulorhexis was 4.9±0.1 mm in Group I and 5.3±0.4 mm in Group II (P<0.001). Mean circularity index was 0.996±0.003 and 0.909±0.047 in Groups I and II, respectively (P<0.001). In Group I, free-floating circular capsulotomies were obtained in 52.5% (21/40) eyes; 37.5% (15/40) eyes had microadhesions; and 10% (4/40) eyes had incomplete capsulotomy in 1–2 clock hours. The incidence of residual adhesions was more in cases with release of white milky fluid (P=0.003). In Group II, a multistep capsulorhexis was performed in 70% (28/40) of the eyes. There was no difference in terms of visual outcomes and intraoperative complications.ConclusionFemtosecond laser-assisted cataract surgery has the advantage of creating a circular and optimally sized capsulotomy in cases of white cataract. The release of white milky fluid during femtosecond laser delivery is the most important factor affecting the creation of a free-floating capsulotomy.
Intraoperative optical coherence tomography (iOCT) is a noninvasive imaging modality that provides a real-time dynamic feedback of the various surgical steps. Comprehensive literature search was performed in MEDLINE using “intraoperative optical coherence tomography” and “iOCT” as keywords. The use of iOCT as an aid to decision-making has been successfully reported in cases undergoing keratoplasty, implantable Collamer lens (ICL) implantation as well as cataract surgery. iOCT helps to assess the graft-host relationship in penetrating keratoplasty. It helps confirm the presence of a big bubble, detect subclinical big bubbles and guide layer by layer stromal dissection in cases of deep anterior lamellar keratoplasty. It acts as a guide during crucial surgical steps in endothelial keratoplasty, right from scoring of the Descemet membrane to ensuring graft apposition at the end of surgery. The morphological features of the corneal incision in phacoemulsification may be assessed. iOCT is a useful tool in assessing the status of the posterior capsule and may help identify preexisting posterior capsular defects during cataract surgery in various clinical scenarios such as posterior polar cataract, traumatic cataract, and vitrectomized eyes. It allows on-table assessment of the ICL vault and potentially facilitates exchange of ICL in the same sitting in extremes of vault. Ocular surface disorders such as ocular surface squamous neoplasia, pterygium, and dermoid may find an application for iOCT, wherein an iOCT-guided stromal dissection will ensure adequate depth of dissection. Further technological advancements may allow for automatic centration and tracking and address the present limitation of instrument-induced shadowing.
Intraoperative vaulting correlates well with postoperative vaulting and can aid in on-table detection of extremes of vaulting and decision-making. It enhances the safety of the surgical procedure by providing a real-time display of the intraoperative manipulations.
Uterine lipoleiomyoma and pure lipoma are uncommon and extremely rare benign lipomatous tumors. Reported incidence is 0.03%–0.25%. Pure cervical lipoma is exceptionally rare. These tumors commonly arise in postmenopausal women. Ultrasonography and computed tomography finding may be nonspecific. Although magnetic resonance imaging can be useful in identifying the fatty nature of the lesion preoperatively, most of the cases postoperatively on histopathological examination. Although various theories of histogenesis of these tumors have been proposed, histogenesis remains to be enigma. These lesions may have coexistent malignancy in uterus, ovaries, and fallopian tubes or may have other metabolic disorders and abnormal estrogen status. Immunohistochemical studies have played an integral role in understanding its complex histogenesis. We did not find any case study in medical literature in which uterine lipoleiomyoma and cervical lipoma have been described in hysterectomy specimen. We report a unique case of a 43-year-old premenopausal woman with complaints of irregular vaginal bleeding and lower abdomen pain. Lipoleiomyoma in uterus corpus and cervical lipoma were diagnosed in hysterectomy specimen.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.