IntroductionSince data regarding new-onset atrial fibrillation (AF) in septic shock patients are scarce, the purpose of the present study was to evaluate the incidence and prognostic impact of new-onset AF in this patient group.MethodsWe prospectively studied all patients with new-onset AF and all patients suffering from septic shock in a non-cardiac surgical intensive care unit (ICU) during a 13 month period.ResultsDuring the study period, 687 patients were admitted to the ICU, of which 58 patients were excluded from further analysis due to pre-existing chronic or intermittent AF. In 49 out of the remaining 629 patients (7.8%) new-onset AF occurred and 50 out of the 629 patients suffered from septic shock. 23 out of the 50 patients with septic shock (46%) developed new-onset AF. There was a steady, significant increase in C-reactive protein (CRP) levels before onset of AF in septic shock patients. ICU mortality in septic shock patients with new-onset AF was 10/23 (44%) compared with 6/27 (22%) in septic shock patients with maintained sinus rhythm (SR) (P = 0.14). During a 2-year follow-up there was a trend towards an increased mortality in septic shock patients with new-onset AF, but the difference did not reach statistical significance (P = 0.075). The median length of ICU stay among surviving patients was longer in patients with new-onset AF compared to those with maintained SR (30 versus 17 days, P = 0.017). The success rate to restore SR was 86%. Failure to restore SR was associated with increased ICU mortality (71.4% versus 21.4%, P = 0.015).ConclusionsAF is a common complication in septic shock patients and is associated with an increased length of ICU stay among surviving patients. The increase in CRP levels before onset of AF may support the hypothesis that systemic inflammation is an important trigger for AF.
Background: COVID-19 convalescent plasma (CCP) has been considered a treatment option in COVID-19. This trial assessed the efficacy of neutralizing antibody containing high-dose CCP in hospitalized adults with COVID-19 requiring respiratory support or intensive care treatment.Methods: Patients (n=105) were randomized 1:1 to either receive standard treatment and 3 units of CCP or standard treatment alone. Control group patients with progress on day 14 could cross over to the CCP group. Primary outcome was a dichotomous composite outcome of survival and no longer fulfilling criteria for severe COVID-19 on day 21. Results:The primary outcome occurred in 43.4% of patients in the CCP and 32.7% in the control group (p=0.32). The median time to clinical improvement was 26 days in the CCP group and 66 days in the control group (p=0.27). Median time to discharge from hospital was 31 days in the CCP and 51 days in the control group (p=0.24). In the subgroup that received a higher cumulative amount of neutralizing antibodies the primary outcome occurred in 56.0% (versus 32.1%), with significantly shorter intervals to clinical improvement (20 versus 66 days)(p<0.05), and to hospital discharge (21 versus 51 days, p=0.03) and better survival (day-60 probability of survival 91.6% versus 68.1%; p=0.02) compared to the control group. Conclusion:CCP added to standard treatment was not associated with significant improvement in the primary and secondary outcomes. A pre-defined subgroup analysis showed a significant benefit for CCP among those who received a larger amount of neutralizing antibodies.
IMPORTANCE End-of-life decisions occur daily in intensive care units (ICUs) around the world, and these practices could change over time.OBJECTIVE To determine the changes in end-of-life practices in European ICUs after 16 years. DESIGN, SETTING, AND PARTICIPANTS Ethicus-2 was a prospective observational study of 22 European ICUs previously included in the Ethicus-1 study (1999)(2000). During a self-selected continuous 6-month period at each ICU, consecutive patients who died or had any limitation of life-sustaining therapy from September 2015 until October 2016 were included. Patients were followed up until death or until 2 months after the first treatment limitation decision.
BackgroundHyperglycemia and insulin resistance frequently occur in critically ill and in morbidly obese (MO) patients. Both conditions are associated with altered serum levels of cytokines and adipokines. In addition, obesity related alterations in adipokine expression contribute to insulin resistance in metabolic syndrome. In this study we examined the serum adipocytokine profile in critically ill patients, MO patients, and healthy blood donors.Methods33 patients who fulfilled the clinical criteria for severe sepsis or septic shock (SP) were prospectively enrolled in this study. A multiplex analysis was performed to evaluate plasma levels of adiponectin, resistin, leptin, active PAI-1, MCP-1, IL-1 alpha, IL-6, IL-8, IL-10, and TNF-alpha in 33 critically ill patients, 37 MO patients and 60 healthy blood donors (BD).ResultsIn SP, adiponectin was significantly lowered and resistin, active PAI-1, MCP-1, IL-1 alpha, IL-6, IL-8, IL-10, and TNF-alpha were significantly elevated compared to BD. Leptin levels were unchanged. In MO, adiponectin and IL-8 were significantly lowered, leptin, active PAI-1, MCP-1, IL-1 alpha, IL-6, and IL-10 significantly elevated, whereas resistin was unaltered.In SP, adiponectin correlated negatively with BMI, SAPS II and SOFA scores, while resistin correlated positively with SAPS II and SOFA scores and leptin correlated positively with the BMI. Adiponectin was approximately equally diminished in SP and MO compared to BD. With the exception of active PAI-1, cytokine levels in SP were clearly higher compared to MO.ConclusionA comparable adipocytokine profile was determined in critically ill and MO patients. As in MO, SP showed reduced adiponectin levels and elevated MCP-1, active PAI-1, IL-1 alpha, IL-6, and IL-10 levels. Leptin is only elevated in MO, while resistin, IL-8, and TNF-alpha is only elevated in SP. As in MO patients, increased levels of proinflammatory cytokines and altered levels of adipokines may contribute to the development of insulin resistance in critically ill patients.
IntroductionCurrent sepsis guidelines recommend antimicrobial treatment (AT) within one hour after onset of sepsis-related organ dysfunction (OD) and surgical source control within 12 hours. The objective of this study was to explore the association between initial infection management according to sepsis treatment recommendations and patient outcome.MethodsIn a prospective observational multi-center cohort study in 44 German ICUs, we studied 1,011 patients with severe sepsis or septic shock regarding times to AT, source control, and adequacy of AT. Primary outcome was 28-day mortality.ResultsMedian time to AT was 2.1 (IQR 0.8 – 6.0) hours and 3 hours (-0.1 – 13.7) to surgical source control. Only 370 (36.6%) patients received AT within one hour after OD in compliance with recommendation. Among 422 patients receiving surgical or interventional source control, those who received source control later than 6 hours after onset of OD had a significantly higher 28-day mortality than patients with earlier source control (42.9% versus 26.7%, P <0.001). Time to AT was significantly longer in ICU and hospital non-survivors; no linear relationship was found between time to AT and 28-day mortality. Regardless of timing, 28-day mortality rate was lower in patients with adequate than non-adequate AT (30.3% versus 40.9%, P < 0.001).ConclusionsA delay in source control beyond 6 hours may have a major impact on patient mortality. Adequate AT is associated with improved patient outcome but compliance with guideline recommendation requires improvement. There was only indirect evidence about the impact of timing of AT on sepsis mortality.
Delay in antimicrobial therapy and source control was associated with increased mortality but the multifaceted approach was unable to change time to antimicrobial therapy in this setting and did not affect survival.
During experimental sepsis, excessive generation of the anaphylatoxin C5a results in reduction of the C5a receptor (C5aR) on neutrophils. These events have been shown to result in impaired innate immunity. However, the regulation and fate of C5aR on neutrophils during sepsis are largely unknown. In contrast to 30 healthy volunteers, 60 patients in septic shock presented evidence of complement activation with significantly increased serum levels of C3a, C5a, and C5b-9. In the septic shock group, the corresponding decrease in complement hemolytic activity distinguished survivors from nonsurvivors. Neutrophils from patients in septic shock exhibited decreased C5aR expression, which inversely correlated with serum concentrations of C-reactive protein (CRP) and clinical outcome. In vitro exposure of normal neutrophils to native pentameric CRP led to a dose- and time-dependent loss of C5aR expression on neutrophils, whereas the monomeric form of CRP, as well as various other inflammatory mediators, failed to significantly alter C5aR levels on neutrophils. A circulating form of C5aR (cC5aR) was detected in serum by immunoblotting and a flow-based capture assay, suggestive of an intact C5aR molecule. Levels of cC5aR were significantly enhanced during septic shock, with serum levels directly correlating with lethality. The data suggest that septic shock in humans is associated with extensive complement activation, CRP-dependent loss of C5aR on neutrophils, and appearance of cC5aR in serum, which correlated with a poor outcome. Therefore, cC5aR may represent a new sepsis marker to be considered in tailoring individualized immune-modulating therapy.
Cytomegalovirus reactivation occurred in one third of patients and was associated with prolonged ventilation and stay in an intensive care unit.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.